NA 358.697Recalls & reported problems
Synthes GmbH · SPIRAL BLADE COUPLING SCREW FOR TI HUMERAL NAILS · Class 1
Data updated Oct 13, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10886982196842), received between Jul 3, 2019 and Jul 3, 2019 — classified as 1 malfunction.
The most frequently reported specific device problem is “Device-Device Incompatibility” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Device-Device Incompatibility1
Patient problems
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionJul 3, 2019Device-Device Incompatibility; Device-Device Incompatibility
DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN (B)(6) AS FOLLOWS: IT WAS REPORTED THAT ON (B)(6) 2019, DURING AN UNKNOWN SURGERY WITH AN EXPERT HUMERAL NAIL, THE SURGEON COULD NOT CONNECT THE COUPLING SCREW WITH AN UNKNOWN SPIRAL BLADE AND AN INSERTER SPIRAL BLADE. THEN, THE SURGEON TRIED AGAIN USING ANOTHER SPIRAL BLADE HOWEVER, THE PROBLEM WAS NOT IMPROVED. CONSEQUENTLY, THE THREADED PART OF THE COUPLING SCREW FOR SPIRAL BLADE LOOKED DAMAGED AND IT COULD NOT BE INSERTED UNTIL AN APPROPRIATE POSITION. EVENTUALLY, THE SURGEON CONNECTED BY ROTATING THE COUPLING SCREW FORCIBLY AND INSERTED THE SPIRAL BLADE SUCCESSFULLY. THERE WAS A LESS THAN 30 MINUTES SURGICAL DELAY WITH NO ADVERSE CONSEQUENCE REPORTED TO THE PATIENT. CONCOMITANT DEVICES REPORTED: UNKNOWN SPIRAL BLADE (PART# UNKNOWN, LOT# UNKNOWN, QUANTITY 2); INSERTER FOR SPIRAL BLADE (PART# 358.696, LOT# UNKNOWN, QUANTITY 1); UNKNOWN EXPERT HUMERAL NAIL (PART# UNKNOWN, LOT# UNKNOWN, QUANTITY 1). THIS IS REPORT 1 OF 1 FOR (B)(4).
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8760196 ↗
Other BIT, DRILL devices
- QUICKSET 2274-25-500Depuy Orthopaedics, Inc. · BIT, DRILL1,985 reports
- QUICKSET 2274-35-500Depuy Orthopaedics, Inc. · BIT, DRILL770 reports
- QUICKSET 2274-30-500Depuy Orthopaedics, Inc. · BIT, DRILL761 reports
- NA 03.037.022Synthes GmbH · BIT, DRILL339 reports
- NA 323.062Synthes GmbH · BIT, DRILL309 reports
- QUICKSET 2274-56-000Depuy (Ireland) · BIT, DRILL275 reports
- QUICKSET 2274-45-500Depuy Orthopaedics, Inc. · BIT, DRILL211 reports
- LCS 2366-83-000Depuy (Ireland) · BIT, DRILL207 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page