Skip to content

YUKON OCT Spinal System 7601-05034Recalls & reported problems

VB Spine LLC · Polyaxial Screw Ø5.0x34 mm · Class 2 · Implant

All models of YUKON OCT Spinal System (54)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
5
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 10888857350045), received between Nov 10, 2020 and Nov 6, 2023 — classified as 5 malfunctions.

The most frequently reported specific device problem is “Fracture” (4 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 1 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Fracture4
  • Material Separation1

Patient problems

  • No Clinical Signs, Symptoms or Conditions3
  • Neck Pain2
  • Pain2

Recent adverse event reports

The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.

  • MalfunctionNov 6, 2023Fracture; Fracture

    A COMPANY REPRESENTATIVE REPORTED THAT AN YUKON POLYAXIAL SCREW FRACTURED AT THE SCREW/TULIP INTERFACE DURING INSERTION. THE SHANK OF THE SCREW WAS RETAINED AT T2 PEDICLE ON THE RIGHT MAKING IT NECESSARY TO EXTEND THE CONSTRUCT TO T3 TO PROVIDE ADEQUATE POINTS OF CONSTRUCT FIXATION. THE PROCEDURE WAS COMPLETED WITH ONE HOUR SURGICAL DELAY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18080142 ↗
  • MalfunctionApr 28, 2023Fracture; Fracture

    A COMPANY REPRESENTATIVE REPORTED THAT TWO YUKON POLYAXIAL SCREWS AT T1 FRACTURED POST-OPERATIVELY. THE PATIENT REPORTED EXPERIENCING NECK PAIN. REVISION SURGERY IS NOT PLANNED. THIS REPORT CAPTURES THE SECOND OF TWO FRACTURED SCREWS.

    Patient problems: Neck Pain; Pain

    MAUDE report 16837661 ↗
  • MalfunctionApr 28, 2023Fracture; Fracture

    A COMPANY REPRESENTATIVE REPORTED THAT TWO YUKON POLYAXIAL SCREWS AT T1 FRACTURED POST-OPERATIVELY. THE PATIENT REPORTED EXPERIENCING NECK PAIN. REVISION SURGERY IS NOT PLANNED. THIS REPORT CAPTURES THE FIRST OF TWO FRACTURED SCREWS.

    Patient problems: Neck Pain; Pain

    MAUDE report 16837647 ↗
  • MalfunctionOct 29, 2021Fracture; Fracture

    THIS REPORT SUMMARIZES ONE MALFUNCTION EVENT WHERE A YUKON OCT POLYAXIAL SCREW BROKE INTRA-OPERATIVELY. SURGERY WAS SUCCESSFULLY COMPLETED WITH NO DELAY. NO ADVERSE CONSEQUENCES OR MEDICAL INTERVENTION WERE REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12723258 ↗
  • MalfunctionNov 10, 2020Material Separation; Material Separation

    IT WAS REPORTED THAT A YUKON OCT POLYAXIAL SCREW TULIP DISENGAGED INTRA-OPERATIVELY. DURING SCREW INSERTION, THE SCREW HEAD KEPT SPINNING AND THE SCREW WOULD NOT ADVANCE. THERE WERE NO ADVERSE CONSEQUENCES TO THE PATIENT. THE PROCEDURE WAS COMPLETED SUCCESSFULLY, WITH A 15 MINUTE SURGICAL DELAY, BY REPLACING THE SCREW.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 10818086 ↗

Other Orthosis, cervical pedicle screw spinal fixation devices

All Orthosis, cervical pedicle screw spinal fixation devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page