AirFlow AF2142MBS-45ERecalls & reported problems
Ventlab, LLC · AirFlow Pediatric Resuscitator with Integrated Manometer, B/V Filter, 40cm Pop-Off, Bag Reservoir, Strap, Gas Sampling Line, and Size 4 & 5 Masks · Class 2
Data updated Oct 13, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 10889483565643), received between Mar 25, 2025 and Dec 18, 2025 — classified as 3 malfunctions.
The most frequently reported specific device problem is “Output Problem” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Output Problem2
- Material Deformation1
Patient problems
- No Clinical Signs, Symptoms or Conditions3
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionDec 18, 2025Output Problem; Output Problem
SUNMED HOLDINGS LLC. RECEIVED A SINGLE REPORT THAT REFERENCED TWO DIFFERENT INCIDENCES, WHICH WERE ASSOCIATED WITH SEPARATE UNITS, INVOLVING TWO DIFFERENT PATIENTS. THIS IS THE FIRST OF TWO REPORTS. REFER TO 1314417-2025-00105 FOR THE SECOND REPORT. IT WAS REPORTED, DURING A RESPIRATORY CALL, THE MEDICAL DIRECTOR ATTEMPTED TO USE THE CAPNO-LINE, PACKAGED WITH THE BAG VALVE MASK (BVM), AND NOTED IT DID NOT PROVIDE ANY READINGS. THE LINE WAS DISCONNECTED AND RECONNECTED WITH AN ADDED EXTRA TWIST; HOWEVER, IT STILL DID NOT PROVIDE ANY READINGS. THE LINE WAS SWITCHED TO A NEW DEVICE, WHICH WORKED IMMEDIATELY. THE LACK OF READING HINDERED PATIENT CARE AND DELAYED TREATMENT ON SCENE; HOWEVER, IT WAS NOTED THE PATIENT WAS NOT AFFECTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23846179 ↗MalfunctionDec 18, 2025Output Problem; Output Problem
SUNMED HOLDINGS LLC. RECEIVED A SINGLE REPORT THAT REFERENCED TWO DIFFERENT INCIDENCES, WHICH WERE ASSOCIATED WITH SEPARATE UNITS, INVOLVING TWO DIFFERENT PATIENTS. THIS IS THE SECOND OF TWO REPORTS. REFER TO 1314417-2025-00104 FOR THE FIRST REPORT. IT WAS REPORTED, DURING A RESPIRATORY CALL, THE MEDICAL DIRECTOR ATTEMPTED TO USE THE CAPNO-LINE, PACKAGED WITH THE BAG VALVE MASK (BVM), AND NOTED IT DID NOT PROVIDE ANY READINGS. THE LINE WAS DISCONNECTED AND RECONNECTED WITH AN ADDED EXTRA TWIST; HOWEVER, IT STILL DID NOT PROVIDE ANY READINGS. THE LINE WAS SWITCHED TO A NEW DEVICE, WHICH WORKED IMMEDIATELY. THE LACK OF READING HINDERED PATIENT CARE AND DELAYED TREATMENT ON SCENE; HOWEVER, IT WAS NOTED THE PATIENT WAS NOT AFFECTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23846178 ↗MalfunctionMar 25, 2025Material Deformation; Material Deformation
IT HAS BEEN REPORTED THAT THE AIRFLOW PEDIATRIC RESUSCITATOR MASK BEING OVAL-SHAPED, MAKING IT DIFFICULT TO CONNECT TO THE BVM, IS A REPORTABLE INCIDENT. THIS ISSUE OCCURS DURING EMERGENCY SITUATIONS, LEADING TO DELAYS IN OXYGEN DELIVERY DUE TO THE MISSHAPEN CONNECTION. SUCH DELAYS COULD RESULT IN SERIOUS HARM OR INJURY IF THE PATIENT DOES NOT RECEIVE OXYGEN QUICKLY ENOUGH.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21692355 ↗
Other Ventilator, Emergency, Manual (Resuscitator) devices
- Ventlab AF5140MBVentlab, LLC · Ventilator, Emergency, Manual (Resuscitator)1 recall8 reports
- Curaplex AF2000Bound Tree Medical, LLC · Ventilator, emergency, manual (resuscitator)1 recall6 reports
- Ventlab AF5140MBPVentlab, LLC · Ventilator, Emergency, Manual (Resuscitator)1 recall5 reports
- Ventlab AF5142MBPVentlab, LLC · Ventilator, Emergency, Manual (Resuscitator)1 recall2 reports
- Ventlab AF2140MBPVentlab, LLC · Ventilator, Emergency, Manual (Resuscitator)1 recall2 reports
- Ventlab AF1140MBVentlab, LLC · Ventilator, Emergency, Manual (Resuscitator)1 recall1 report
- Ventlab AF2142MBVentlab, LLC · Ventilator, Emergency, Manual (Resuscitator)1 recall1 death1 report
- Ventlab VN3100OBVentlab, LLC · Ventilator, Emergency, Manual (Resuscitator)1 recall1 report
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page