MicroCutter 30 Curved Tip Blue Reload FG-025321Recalls & reported problems
Aesdex, LLC · MicroCutter 30 Curved Tip Blue Reload is compatible with the MicroCutter 5/80 Stapler · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 11814900003216), received between Sep 1, 2017 and Sep 1, 2017 — classified as 1 injury.
The most frequently reported specific device problem is “Difficult to Remove” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Difficult to Remove1
- Sticking1
Patient problems
- Blood Loss1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjurySep 1, 2017Difficult to Remove; Sticking; Difficult to Remove; Sticking
THE PATIENT WAS UNDERGOING A VATS ROBOTIC LEFT LOWER LOBECTOMY. FOR THE SECOND FIRING OF THE MICROCUTTER STAPLER, A BLUE RELOAD WAS USED TO TRANSECT A BRANCH OF THE PULMONARY ARTERY. UPON OPENING THE STAPLER, STAPLES WERE NOTED TO BE DEPLOYED, WITH SOME STICKING OF THE TISSUE ON THE LEFT SIDE OF THE LOWER JAW. THE STAPLER WAS ROLLED, WITH TENSION NOTED ON THE VESSEL, FOLLOWED BY BLEEDING AT THE LEFT SIDE OF THE VESSEL TRANSECTION. THE PROCEDURE WAS CONVERTED TO AN OPEN PROCEDURE. THE PATIENT WAS REPORTED TO HAVE BEEN TRANSFERRED TO A STANDARD ROOM AND TO BE DOING WELL FOLLOWING THE SURGERY.
Patient problems: Blood Loss
MAUDE report 6838108 ↗
Other Staple, Implantable devices
- Endo GIA EGIA60AMTCovidien LP · STAPLE, IMPLANTABLE19 deaths10,680 reports
- Endo GIA Ultra EGIAUSTNDCovidien LP · STAPLE, IMPLANTABLE5 deaths9,730 reports
- Signia SIGPHANDLECovidien LP · STAPLE, IMPLANTABLE1 recall3 deaths5,356 reports
- ECHELON FLEX PSEE60AEthicon Endo-Surgery, LLC · STAPLE, IMPLANTABLE1 recall13 deaths3,294 reports
- Endo GIA Ultra EGIAUSHORTCovidien LP · STAPLE, IMPLANTABLE2 deaths3,011 reports
- Endo GIA EGIA45AMTCovidien LP · STAPLE, IMPLANTABLE10 deaths2,965 reports
- Endo GIA Ultra EGIAUXLCovidien LP · STAPLE, IMPLANTABLE2,909 reports
- ENDOPATH ATS45Ethicon Endo-Surgery, LLC · STAPLE, IMPLANTABLE2 deaths2,046 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page