MINILAP IPN914229Recalls & reported problems
Teleflex Incorporated · MiniGrip Alligator Grasper · Class 2
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 14026704640086), received between Oct 4, 2021 and Jul 10, 2023 — classified as 4 malfunctions.
The most frequently reported specific device problem is “Break” (4 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- Break4
Patient problems
- No Clinical Signs, Symptoms or Conditions4
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
MalfunctionJul 10, 2023Break; Break
IT WAS REPORTED THAT "A PIECE BROKE OFF IN PATIENT DURING PROCEDURE. PROCEDURE LASTED 1 HOUR LONGER DUE TO LOOKING FOR PIECE THAT BROKE OFF". ADDITIONAL INFORMATION RECEIVED STATES THAT "A PIECE OF ONE OF THE ARMS OF THE ALLIGATOR FORCEPS BROKE OFF DURING THE CASE AND SO WE HAD TO GET THE FLUOROSCOPIC GUIDANCE PER RADIOLOGY TO HELP FIND THE MISSING PIECE AND THEN REMOVE IT FROM THE PATIENT'S ABDOMINAL WALL." ALL PIECES WERE SUCCESSFULLY REMOVED FROM THE PATIENT. ANOTHER DEVICE WAS NOT USED TO COMPLETE THE PROCEDURE. NO PATIENT HARM OR INJURY. THE PATIENT STATUS IS REPORTED AS "GOOD".
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17292009 ↗MalfunctionJun 9, 2023Break; Break
IT WAS REPORTED THAT WHILE IN USE DURING A LAPAROSCOPIC CHOLECYSTECTOMY, "THE JAW AT THE END OF THE DEVICE BROKE OFF INTO THE PATIENT DURING PROCEDURE. SURGEON HAD TO FISH OUT BROKEN PIECE". NO PATIENT HARM OR INJURY. THE PATIENT STATUS IS REPORTED AS "FINE". ADDITIONAL INFORMATION RECEIVED STATES THAT "ALL PIECES WERE REMOVED SUCCESSFULLY. THE DEVICE WAS REMOVED FROM THE PATIENT AND PLACED TO THE SIDE TO BE INVESTIGATED". PER THE CUSTOMER IT IS UNKNOWN IF A NEW APPLIER WAS USED TO COMPLETE THE PROCEDURE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17100745 ↗MalfunctionDec 5, 2022Break; Break
IT WAS REPORTED THAT THE JAW BROKE DURING USE. THERE WAS NO REPORTED INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15920025 ↗MalfunctionOct 4, 2021Break; Break
SHAFT OF PGAC300 BROKE TOWARDS THE DISTAL TIP OF THE PRODUCT WHEN ARMED AND INSERTING INTO THE ABDOMEN.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12569122 ↗
FDA clearance and classification
Cleared through 510(k) K172775 on Feb 12, 2018 (decision: Substantially Equivalent). Submitted by Teleflexmedical, Inc. as “MiniLap System with MiniGrip Handle, MiniLap System with ThumbGrip Handle”. The FDA review took 151 days. FDA record ↗
The FDA regulates product code OCW (endoscopic tissue approximation device) under 21 CFR 876.1500 as a Class II device. 21 CFR 876.1500 ↗
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the MINILAP IPN914229
Has the MINILAP IPN914229 been recalled?
No FDA recall record in our data names this exact device identifier (DI 14026704640086), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the MINILAP IPN914229?
The FDA's MAUDE database lists 4 adverse event reports for this device, received between Oct 4, 2021 and Jul 10, 2023. In those reports, the most common specific device problem is “Break” (4). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the MINILAP IPN914229?
None of the reports are classified as deaths, 0 as injuries and 4 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the MINILAP IPN914229 FDA approved?
It was cleared through 510(k) K172775 on Feb 12, 2018. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.
Who makes the MINILAP IPN914229, and is it still sold?
The FDA's device database lists Teleflex Incorporated as the company responsible for it (brand MINILAP, model IPN914229). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Endoscopic tissue approximation device devices
- Endo Stitch 173016Covidien LP · Endoscopic tissue approximation device1 death1,332 reports
- ProTack 174006Covidien LP · Endoscopic tissue approximation device705 reports
- N/A ECS29AEthicon Endo-Surgery, LLC · Endoscopic tissue approximation device1 death517 reports
- N/A ECS25AEthicon Endo-Surgery, LLC · Endoscopic tissue approximation device233 reports
- OverStitch™ M00505530Boston Scientific Corporation · Endoscopic tissue approximation device1 recall75 reports
- Polysorb 170053Covidien LP · Endoscopic tissue approximation device1 recall63 reports
- Surgidac 173024Covidien LP · Endoscopic tissue approximation device70 reports
- NA M00505550Boston Scientific Corporation · Endoscopic tissue approximation device1 recall12 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page