Skip to content

AU OSR6111Recalls & reported problems

Beckman Coulter, Inc. · Direct Bilirubin · Class 2

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 15099590010102), received between May 15, 2021 and May 15, 2021 — classified as 1 injury.

The most frequently reported specific device problem is “High Test Results” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • High Test Results1

Patient problems

  • Insufficient Information1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryMay 15, 2021High Test Results; High Test Results

    THE CUSTOMER REPORTED RECEIVING ERRONEOUS HIGH PATIENT RESULTS FOR DIRECT BILIRUBIN (DBIL) ON THE AU480 CLINICAL CHEMISTRY ANALYZER FOR NEONATAL SAMPLES. THE ERRONEOUS RESULTS WERE REPORTED OUTSIDE OF THE LAB. THERE WAS A REPORT OF A CHANGE TO PATIENT TREATMENT. PATIENTS HAD A PROLONGED HOSPITAL STAY WITH ADDITIONAL FOLLOW UP TESTING/MONITORING. IT IS UNKNOWN IF ADDITIONAL TREATMENT WAS RECEIVED.

    Patient problems: Insufficient Information

    MAUDE report 11830081 ↗

FDA clearance and classification

Cleared through 510(k) K924963 on Nov 30, 1992 (decision: Substantially Equivalent). Submitted by Olympus Corp. as “Olympus Direct Bilirubin Reagent”. The FDA review took 61 days. FDA record ↗

The FDA regulates product code CIG (diazo colorimetry, bilirubin) under 21 CFR 862.1110 as a Class II device. 21 CFR 862.1110 ↗

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the AU OSR6111

Has the AU OSR6111 been recalled?

No FDA recall record in our data names this exact device identifier (DI 15099590010102), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the AU OSR6111?

The FDA's MAUDE database lists 1 adverse event report for this device, received on May 15, 2021. That report lists device problem “High Test Results” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the AU OSR6111?

None of the reports are classified as deaths, 1 as an injury and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the AU OSR6111 FDA approved?

It was cleared through 510(k) K924963 on Nov 30, 1992. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Who makes the AU OSR6111, and is it still sold?

The FDA's device database lists Beckman Coulter, Inc. as the company responsible for it (brand AU, model OSR6111). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Diazo Colorimetry, Bilirubin devices

All Diazo Colorimetry, Bilirubin devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page