Skip to content

AU OSR6222Recalls & reported problems

Beckman Coulter, Inc. · Inorganic Phosphorus · Class 1

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 15099590020118), received between Apr 8, 2020 and Apr 8, 2020 — classified as 1 injury.

The most frequently reported specific device problem is “Low Test Results” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Low Test Results1

Patient problems

  • No Information1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryApr 8, 2020Low Test Results; Low Test Results

    ON 28-FEBRUARY-2020, THE CUSTOMER REPORTED THE GENERATION OF FALSE LOW PHOSPHORUS RESULT FOR ONE (1) PATIENT ON THE AU5800 CLINICAL CHEMISTRY ANALYZER. THE DOCTOR QUESTIONED THE PATIENT RESULTS AS THEY DID NOT MATCH THE PATIENT CLINICAL PRESENTATION. THE PATIENT HAD BEEN TREATED WITH AN IV ADMINISTRATION OF AMPHOTERICIN B LIPOSOMAL AT 65 MG ADMINISTERED OVER 120 MINS PRIOR TO THE BLOOD DRAW. LIPOSOMAL AMPHOTERICIN-B (L-AMB) IS A FORMULATION OF AMPHOTERICIN B THAT HAS BEEN EMBEDDED IN A UNILAMELLAR PHOSPHOLIPID BILAYER. THIS SPECIFIC FORMULATION IS LESS TOXIC AND HAS BEEN APPROVED FOR INVASIVE ASPERGILLUS, CANDIDA, AND CRYPTOCOCCUS INFECTIONS AT DOSAGES FROM 3 TO 6 MG/KG/DAY. ON 01-APRIL-2020, THE CUSTOMER NOTIFIED BECKMAN COULTER THAT THE PATIENT WAS ADMINISTERED POTASSIUM PHOSPHATE TO REMEDIATE THE ¿LOW¿ PHOSPHORUS LEVELS. A SELECTION OF SAMPLES FROM THE SAME PATIENT WERE SENT TO ANOTHER LABORATORY TO CONFIRM THE RESULTS. THE SAMPLES WERE TESTED USING THE ABBOTT ARCHITECT AND SOME RESULTS WERE FOUND DISCREPANT. THE VARIABILITY IN RESULTS MAY BE EXPLAINED BY THE ADMINISTRATION OF POTASSIUM PHOSPHATE TO REMEDIATE THE ¿LOW¿ PHOSPHORUS LEVELS.

    Patient problems: No Information

    MAUDE report 9940986 ↗

FDA clearance and classification

Cleared through 510(k) K925057 on Nov 19, 1992 (decision: Substantially Equivalent). Submitted by Olympus Corp. as “Olympus Inorganic Phosphorus Reagent”. The FDA review took 44 days. FDA record ↗

The FDA regulates product code CEO (phosphomolybdate (colorimetric), inorganic phosphorus) under 21 CFR 862.1580 as a Class I device. 21 CFR 862.1580 ↗

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the AU OSR6222

Has the AU OSR6222 been recalled?

No FDA recall record in our data names this exact device identifier (DI 15099590020118), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the AU OSR6222?

The FDA's MAUDE database lists 1 adverse event report for this device, received on Apr 8, 2020. That report lists device problem “Low Test Results” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the AU OSR6222?

None of the reports are classified as deaths, 1 as an injury and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the AU OSR6222 FDA approved?

It was cleared through 510(k) K925057 on Nov 19, 1992. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Who makes the AU OSR6222, and is it still sold?

The FDA's device database lists Beckman Coulter, Inc. as the company responsible for it (brand AU, model OSR6222). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.