Access CEA 33200Recalls & reported problems
Beckman Coulter, Inc. · The Access CEA assay is a paramagnentic particle, chemiluminescent immunoassay for the quantitative determination of Carcinoembryonic Antigen (CEA) levels in human serum, using the Access Immunoassay Systems. · Class 2
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 3
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 15099590624842), received between Mar 22, 2018 and Jul 6, 2022 — classified as 3 injuries.
The most frequently reported specific device problem is “High Test Results” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- High Test Results3
Patient problems
- No Code Available2
- Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
InjuryJul 6, 2022High Test Results; High Test Results
THE CUSTOMER REPORTED ERRONEOUS REPRODUCIBLE ELEVATED CEA (ACCESS CEA (CARCINOEMBRYONIC ANTIGEN), PART NUMBER 33200 AND LOT NUMBER 295069) WERE GENERATED FOR ONE (1) PATIENT ON THE CUSTOMER'S DXI (UNICEL DXI 800 ACCESS IMMUNOASSAY ANALYZER, PART NUMBER 973100 AND SERIAL NUMBER (B)(4)) ON (B)(6) 2002. ON (B)(6) 2022 THE CUSTOMER REPORTED A CHANGE TO PATIENT TREATMENT OR MANAGEMENT OCCURRED IN CONJUNCTION WITH THE INCIDENT. THE PATIENT UNDERWENT A FIBROSCOPY AND AN ENDOSCOPY. THERE WAS NO FURTHER REPORT OF CHANGE TO PATIENT TREATMENT OR PATIENT OUTCOME. THE ORIGINAL CEA PATIENT RESULT WAS OVER RANGE (OVR FLAGGED) >994.0 G/L ON (B)(6) 2022 (9:31). IT WAS MANUALLY DILUTED AND FOLLOWING RESULTS WERE OBTAINED: 5.5 G/L AND 5.7 G/L WHEN DILUTED 1/10 ON (B)(6) 2022. ON (B)(6) 2002 THE PATIENT SAMPLE WAS TESTED FOR CEA; RESULTS OF 939.8 G/L AND 968.9 G/L WERE OBTAINED. ON (B)(6) 2022, PATIENT SAMPLE WAS TESTED AS FOLLOWS: 1.4 G/L WHEN DILUTED 1/2 AND 2841.5 G/L WHEN DILUTED AT 1/10. THE CUSTOMER¿S DILUTION WERE NOT LINEAR. THE PATIENT SAMPLE WAS ALSO TESTED FOR CEA USING THE ROCHE COBAS METHOD; RESULTS WERE LOW AT 3.4 NG/ML (<4.7 NG/ML) ON (B)(6) 2022 AND 3.1 NG/ML ON (B)(6) 2022 (SECOND SAM
Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available
MAUDE report 14939288 ↗InjuryDec 19, 2019High Test Results; High Test Results
THE CUSTOMER CONTACTED BECKMAN COULTER (BEC) TO REPORT OBTAINING REPRODUCIBLE ELEVATED CARCINOEMBRYONIC ANITGEN (ACCESS CEA) RESULTS FOR ONE (1) PATIENT ON THE LABORATORY'S UNICEL DXI 800 ACCESS IMMUNOASSAY SYSTEM, SERIAL NUMBER (B)(4). IN (B)(6) 2018 (EXACT DATE IS UNKNOWN) THE PATIENT HAD AN EXTREMELY ELEVATED ACCESS CEA RESULT, POST LUNG SURGERY (SURGERY OCCURRED IN (B)(6) 2017). THEN AGAIN IN (B)(6) 2018 (EXACT DATE IS UNKNOWN) THE SAME PATIENT HAD ANOTHER SIGNIFICANTLY ELEVATED ACCESS CEA RESULT. THE CUSTOMER NOTED THAT THE PATIENT'S OTHER TUMOR MARKERS (EXACT TESTS WERE NOT SUPPLIED) WERE ALL WITHIN THE APPROPRIATE CLINICAL RANGES. IN (B)(6) 2018 THE PATIENT UNDERWENT A PET CT (POSITRON EMISSION TOMOGRAPHY/COMPUTED TOMOGRAPHY) SCAN WITH CONTRAST DYE WHICH WAS DISCORDANT TO THE ACCESS CEA RESULTS OBTAINED TO DATE. ADDITIONAL ELEVATED ACCESS CEA RESULTS WERE ALSO OBTAINED IN (B)(6) 2018, (B)(6) 2019 AND (B)(6) 2019. AFTER OBTAINING ALL OF THE REPRODUCIBLE ELEVATED ACCESS CEA RESULTS THE PATIENT WENT TO TWO (2) OTHER HOSPITALS ((B)(6)) WHICH TESTED FOR CEA ON DIFFERENT METHODOLOGIES (EXACT METHODS ARE UNKNOWN). THOSE RESULTS CAME BACK WITHIN THE ASSAYS' NORMAL REFERENCE RANGES W
Patient problems: No Code Available
MAUDE report 9497315 ↗InjuryMar 22, 2018High Test Results; High Test Results
THE CUSTOMER REPORTED OBTAINING AN ELEVATED CARCINOEMBRYONIC ANTIGEN (ACCESS CEA) RESULT FOR ONE PATIENT INVOLVING THE LABORATORY'S ACCESS 2 IMMUNOASSAY SYSTEM PORTION TO THEIR UNICEL DXC 600I SYNCHRON ACCESS CLINICAL SYSTEM (SERIAL NUMBER (B)(4)). THE RESULT WAS REPORTED OUT OF THE LABORATORY. DUE TO THE ELEVATED RESULT, THE PATIENT HAD A CAT SCAN AND A COLONOSCOPY. THE CUSTOMER REPORTED THAT THE RESULTS WERE NEGATIVE. THERE WAS NO REPORT OF ADDITIONAL CHANGE TO TREATMENT. APPROXIMATELY ONE MONTH LATER ANOTHER SAMPLE WAS COLLECTED FROM THE PATIENT AND ANALYZED TWO TIMES ON THE SAME ACCESS 2 IMMUNOASSAY SYSTEM PORTION TO THEIR UNICEL DXC 600I SYNCHRON ACCESS CLINICAL SYSTEM. THIS SAMPLE RECOVERED WITH LOWER ACCESS CEA RESULTS. QUALITY CONTROL (QC), CALIBRATION AND SYSTEM CHECK WERE PERFORMING WITHIN ASSAY AND INSTRUMENT SPECIFICATIONS AT THE TIME OF THE EVENT. THERE WERE NO HARDWARE ERRORS OR OTHER ASSAY ISSUES REPORTED IN CONJUNCTION WITH THIS EVENT. THE SAMPLES WERE COLLECTED IN SERUM TUBES AND CENTRIFUGED AT 3150 REVOLUTIONS PER MINUTE (RPM) FOR TEN MINUTES AT ROOM TEMPERATURE. NO ISSUES WITH SAMPLE INTEGRITY WERE REPORTED.
Patient problems: No Code Available
MAUDE report 7362004 ↗
FDA clearance and classification
The FDA regulates product code DHX (system, test, carcinoembryonic antigen) under 21 CFR 866.6010 as a Class II device. 21 CFR 866.6010 ↗
Devices of this type normally need 510(k) clearance before sale.
Common questions about the Access CEA 33200
Has the Access CEA 33200 been recalled?
No FDA recall record in our data names this exact device identifier (DI 15099590624842), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the Access CEA 33200?
The FDA's MAUDE database lists 3 adverse event reports for this device, received between Mar 22, 2018 and Jul 6, 2022. In those reports, the most common specific device problem is “High Test Results” (3). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the Access CEA 33200?
None of the reports are classified as deaths, 3 as injuries and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Who makes the Access CEA 33200, and is it still sold?
The FDA's device database lists Beckman Coulter, Inc. as the company responsible for it (brand Access CEA, model 33200). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other System, Test, Carcinoembryonic Antigen devices
- ADVIA Centaur® CEA 10309977Siemens Healthcare Diagnostics Inc. · SYSTEM, TEST, CARCINOEMBRYONIC ANTIGEN14 reports
- ARCHITECT 07K68-27Abbott Ireland Diagnostics · SYSTEM, TEST, CARCINOEMBRYONIC ANTIGEN13 reports
- Elecsys CEA 07027079190Roche Diagnostics GmbH · SYSTEM, TEST, CARCINOEMBRYONIC ANTIGEN13 reports
- Atellica IM CEA 10995523Siemens Healthcare Diagnostics Inc. · SYSTEM, TEST, CARCINOEMBRYONIC ANTIGEN11 reports
- ADVIA Centaur® CEA 10309978Siemens Healthcare Diagnostics Inc. · SYSTEM, TEST, CARCINOEMBRYONIC ANTIGEN10 reports
- IMMULITE® 2000 Systems CEA 10380995Siemens Healthcare Diagnostics Products Ltd · SYSTEM, TEST, CARCINOEMBRYONIC ANTIGEN9 reports
- Elecsys Anti-CCP 07251670190Roche Diagnostics GmbH · SYSTEM, TEST, CARCINOEMBRYONIC ANTIGEN8 reports
- ARCHITECT 07K68-35Abbott Ireland Diagnostics · SYSTEM, TEST, CARCINOEMBRYONIC ANTIGEN8 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page