Change Healthcare Cardiology Hemo 14.1.1Recalls & reported problems
Change Healthcare Israel Ltd · Class 2
2 open recalls name this device. See the recall details and contact the manufacturer or your healthcare provider.
- Adverse event reports
- 1
- Deaths reported
- 1
- Injuries reported
- 0
- Recalls naming it
- 2
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 17540262100020), received between Feb 20, 2020 and Feb 20, 2020 — classified as 1 death.
The most frequently reported specific device problem is “Application Program Problem” (1 report).
2 FDA recall records name this device's identifier, 2 still open.
8 other recalls cover devices cleared under the same FDA submission (K131497); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Recalls naming this device
- Dec 2, 2024Open, Classified
Software defect concerning autosave mechanism may result in the clinician administering incorrect medication(s).
Z-0958-2025 · Root cause: Software design · FDA record ↗
- Aug 21, 2024Open, Classified
A potential issue has been identified in Change Healthcare Cardiology Hemo where incorrect data entry can lead to inaccurate hemodynamic calculations, potentially resulting in misdiagnosis and inappropriate treatment. This issue occurs when the unit of measurement (UOM) for hemoglobin is configured in a way that differs from the users understanding.
Z-0126-2025 · Root cause: Use error · FDA record ↗
Most reported problems
Device problems
- Application Program Problem1
- Computer Software Problem1
- Unintended Application Program Shut Down1
Patient problems
- Death1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
DeathFeb 20, 2020Computer Software Problem; Application Program Problem; Unintended Application Program Shut Down; Computer Software Problem; Application Program Problem; Unintended Application Program Shut Down
IT WAS REPORTED THAT DURING A PROCEDURE IN THE CATHETERIZATION LAB INVOLVING A PATIENT IN FULL CARDIAC ARREST UNDERGOING CPR, DEFIBRILLATION, AND ARTIFICIAL VENTILATION, THAT THE RT MONITOR WENT BLANK MULTIPLE TIMES AND REBOOTED FOR SEVERAL SECONDS AND RETURNED TO FULL FUNCTIONALITY. DURING THE PROCEDURE AND THE REPORTED RT MONITOR BLANKING OUT EVENTS, AS INDICATED IN THE DEVICE INSTRUCTIONS FOR USE AUXILIARY DEVICES WERE USED TO MONITOR THE PATIENT'S VITAL SIGNS. SUBSEQUENT TO THE PROCEDURE THE PATIENT EXPIRED.
Patient problems: Death
MAUDE report 9731301 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K131497. One submission often covers many models, so check the product and lot details in each record.
- Z-2071-2025 · May 22, 2025 · Open, ClassifiedChange Healthcare Cardiology Hemo Software
- Z-0957-2025 · Dec 2, 2024 · Open, ClassifiedMcKesson Cardiology Hemo software
- Z-0128-2025 · Aug 21, 2024 · Open, ClassifiedMcKesson Cardiology Hemo. Versions 13.0, 13.1.1, 13.1.2, 13.2, 13.2.1, 14.0.
- Z-1490-2019 · Mar 25, 2019 · TerminatedMcKesson Cardiology Hemo
- Z-1489-2019 · Mar 25, 2019 · TerminatedHorizon Cardiology Hemo
- Z-2968-2018 · Mar 12, 2018 · TerminatedMcKesson Cardiology Hemo, Release SW version 13.0. Used for physiological monitoring, image and data processing. McKesson Cardiology Hemo is intended for complete physiological/h
- Z-0042-2015 · Aug 27, 2014 · TerminatedMcKesson Cardiology" Hemo intended for complete physiological/hemodynamic monitoring, clinical data acquisition, medical image and data processing, and analytical assessment.
- Z-0093-2015 · Jun 25, 2014 · TerminatedMcKesson Cardiology Hemo. McKesson Cardiology" Hemo is intended for complete physiological/hemodynamic monitoring, clinical data acquisition, medical image and data processing, an
Other Monitor, Physiological, Patient (Without Arrhythmia Detection Or Alarms) devices
- Rad-97 9738Masimo Corporation · Monitor, Physiological, Patient (Without Arrhythmia Detection Or Alarms)1 death222 reports
- Xper Flex Cardio Physiomonitoring System Xper Flex Cardio FC2010 REV CPhilips Ds North America LLC · MONITOR,PHYSIOLOGICAL,PATIENT(WITHOUT ARRHYTHMIA DETECTION OR ALARMS)2 recalls1 death42 reports
- Xper Flex Cardio Physiomonitoring System FC 2010Philips Ds North America LLC · MONITOR,PHYSIOLOGICAL,PATIENT(WITHOUT ARRHYTHMIA DETECTION OR ALARMS)2 recalls2 deaths38 reports
- Welch Allyn, Inc. 901058Welch Allyn, Inc. · MONITOR,PHYSIOLOGICAL,PATIENT(WITHOUT ARRHYTHMIA DETECTION OR ALARMS)2 recalls5 reports
- Welch Allyn, Inc. 901060Welch Allyn, Inc. · MONITOR,PHYSIOLOGICAL,PATIENT(WITHOUT ARRHYTHMIA DETECTION OR ALARMS)2 recalls3 reports
- Welch Allyn, Inc. 901060Welch Allyn, Inc. · MONITOR,PHYSIOLOGICAL,PATIENT(WITHOUT ARRHYTHMIA DETECTION OR ALARMS)2 recalls2 reports
- McKesson Cardiology Hemo 14.0Change Healthcare Canada Company · Monitor,Physiological,Patient(Without Arrhythmia Detection Or Alarms)2 recalls2 deaths2 reports
- Change Healthcare Cardiology Hemo 14.2Change Healthcare Canada Company · Monitor, Physiological, Patient (Without Arrhythmia Detection Or Alarms)2 recalls1 death1 report
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.