Palmaz BLUE Transhepatic Biliary Stent on SLALOM .018 System PB1570BSSRecalls & reported problems
Cordis US Corp. · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 20705032035986), received between Apr 30, 2019 and Jan 6, 2023 — classified as 4 malfunctions.
The most frequently reported specific device problem is “Defective Component” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Defective Component2
- Device Dislodged or Dislocated1
- Inflation Problem1
Patient problems
- No Consequences Or Impact To Patient2
- No Clinical Signs, Symptoms or Conditions1
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
MalfunctionJan 6, 2023Inflation Problem; Inflation Problem
AS REPORTED, A 7X15 80 PALMAZ BLUE TRANSHEPATIC BILIARY BALLOON EXPANDABLE STENT DELIVERY SYSTEM WAS DEFECTIVE AND DID NOT EXPAND DURING DELIVERY. THERE WAS NO REPORTED PATIENT INJURY. THE PRODUCT WAS STORED PER LABELING AND OPENED IN A STERILE FIELD. THE DEVICE WILL BE RETURNED FOR EVALUATION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16112490 ↗MalfunctionOct 3, 2019Defective Component; Defective Component
PRIOR TO USE IN THE PATIENT, THE PALMAZ BLUE/SLALOM 7X15/80 BALLOON STENT DELIVERY SYSTEM ¿BROKE¿ AS THE STENT WAS LOOSE ON THE BALLOON. THERE WAS NO PATIENT INJURY. THE DEVICE WAS NOT RETURNED FOR ANALYSIS.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9152621 ↗MalfunctionJul 24, 2019Defective Component; Defective Component
AS REPORTED, A PALMAZ BLUE SLALOM 7X15/80 ENDOVASCULAR BALLOON-EXPANDABLE STENT (SDS) WAS LOOSE ON THE BALLOON, THE PRODUCT WAS NOT USED. THERE WAS NO REPORTED PATIENT INJURY.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 8822490 ↗MalfunctionApr 30, 2019Device Dislodged or Dislocated; Device Dislodged or Dislocated
AS REPORTED, THE STENT OF THE BLUE/SLALOM 7X15/80 BIL PACKAGED FELL OFF THE DELIVERY SYSTEM WHILE PREPPING THE DEVICE. THERE WERE NO REPORTED PATIENT INJURIES. THE DEVICE WAS STORED IN THE CATH LAB FOR APPROXIMATELY ONE TO TWO MONTHS. THE PRODUCT WAS STORED, HANDLED AND PREPPED PER THE INSTRUCTIONS FOR USE (IFU). THERE WAS NO DAMAGE NOTICED TO THE DEVICE PRIOR TO OPENING THE PACKAGE. THERE WAS NO DIFFICULTY REMOVING THE DEVICE FROM THE STERILE PACKAGING. THERE WAS NO KINK TO ANY PART OF THE DEVICE. THERE WAS NOTHING UNUSUAL NOTED TO THE STENT DELIVERY SYSTEM PRIOR TO USE. THERE WAS NO UNUSUAL FORCE USED AT ANY TIME. THE PROCEDURE WAS COMPLETED BY USING A NEW 7X15X80 PALMAZ BLUE STENT. THE DEVICE WILL NOT BE RETURNED FOR EVALUATION AS IT WAS DISCARDED BY THE SITE.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8564520 ↗
Other CATHETER, BILIARY, DIAGNOSTIC devices
- Hurricane™ RX M00545900Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC2 recalls1 death705 reports
- MUSTANG™ H74939171060470Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC384 reports
- CRE™ PRO M00558710Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC1 recall284 reports
- Hurricane™ RX M00545920Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC2 recalls211 reports
- MUSTANG™ H74939171070470Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC265 reports
- MUSTANG™ H74939171050470Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC212 reports
- Hurricane™ RX M00545940Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC2 recalls109 reports
- MUSTANG™ H74939171100470Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC203 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page