PALMAZ GENESIS Transhepatic Biliary Stent on OPTA PRO .035" Delivery System PG2970BPXRecalls & reported problems
Cordis Corporation · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 20705032039649), received between Aug 6, 2019 and May 6, 2021 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Burst Container or Vessel” (1 report).
1 other recall cover devices cleared under the same FDA submission (K033394); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Burst Container or Vessel1
- Device Dislodged or Dislocated1
- Therapy Delivered to Incorrect Body Area1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionMay 6, 2021Burst Container or Vessel; Burst Container or Vessel
AS REPORTED, THE BALLOON OF A PALMAZ LONG GENESIS ON .035¿ 29 X 70 X 135 OPTA PRO BALLOON EXPANDABLE STENT DELIVERY SYSTEM WAS SUSPECTED TO HAVE A LEAK AND WOULD NOT HOLD PRESSURE DURING INFLATION TO FULLY EXPAND/DEPLOY THE STENT. THEREFORE, IT WAS REPLACED WITH A NON-CORDIS BALLOON TO FINISH EXPANDING THE STENT TO PROFILE IN THE RIGHT RENAL ARTERY. THERE WAS NO REPORTED PATIENT INJURY. THE DEVICE IS STORED AND MONITORED IN THE WAVEMARK TECHNOLOGY CABINETS. THE DEVICE WILL NOT BE RETURNED FOR EVALUATION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11785693 ↗MalfunctionAug 6, 2019Therapy Delivered to Incorrect Body Area; Device Dislodged or Dislocated; Therapy Delivered to Incorrect Body Area; Device Dislodged or Dislocated
AS REPORTED, A PALMAZ GENESIS LONG PRO 29 X 70 BIL 125 ENDOVASCULAR BALLOON-EXPANDABLE STENT (SDS) BECAME DISLODGED FROM THE BALLOON AND WAS UNABLE TO BE RECOVERED. THERE WAS NO REPORTED PATIENT INJURY. THE STENT WAS DEPLOYED IN THE PATIENT¿S RADIAL ARTERY, NOT THE DESIRED DESTINATION. THE STENT WAS STORED AND PREPPED ACCORDING TO THE INSTRUCTIONS FOR USE (IFU). THE TARGET LESION WAS IN THE RIGHT RENAL ARTERY. THERE WAS A LITTLE VESSEL TORTUOSITY. THERE WAS MODERATE VESSEL ANGULATION. THE DEVICE WAS NOT BEING USED TO TREAT CHRONIC TOTAL OCCLUSION (CTO). THE PRODUCT LOOKED NORMAL WHEN IT WAS REMOVED FROM THE PACKAGING. THERE WAS NOT ANY DIFFICULTY REMOVING THE PRODUCT FROM THE HOOP. THERE WAS NOT ANY DIFFICULTY REMOVING THE PROTECTIVE BALLOON COVER. THERE WAS NOT ANY DIFFICULTY REMOVING THE STYLET OR ANY OF THE STERILE PACKAGING COMPONENTS. THERE WERE NOT ANY KINKS OR OTHER DAMAGES NOTED PRIOR TO INSERTING THE PRODUCT INTO THE PATIENT. THERE WAS 100% CONTRAST USED FOR ROADMAPPING. THE INDEFLATOR WAS USED SUCCESSFULLY WITH OTHER DEVICES. THERE WAS RESISTANCE/FRICTION WHILE INSERTING THE BALLOON THROUGH THE GUIDE CATHETER, THE GUIDE WAS REMOVED AND THEY WENT BARE BACK ON THE WIRE. THE
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 8866518 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K033394. One submission often covers many models, so check the product and lot details in each record.
- Z-1363-2022 · May 20, 2022 · Open, ClassifiedPALMAZ GENESIS Transhepatic Biliary Stent on OPTA PRO .035" Delivery System, Catalog numbers PG2990BPS, PG2990BPX, PG3990BPS, PG3990BPX.
Other CATHETER, BILIARY, DIAGNOSTIC devices
- Hurricane™ RX M00545900Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC2 recalls1 death705 reports
- MUSTANG™ H74939171060470Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC384 reports
- CRE™ PRO M00558710Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC1 recall284 reports
- Hurricane™ RX M00545920Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC2 recalls211 reports
- MUSTANG™ H74939171070470Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC265 reports
- MUSTANG™ H74939171050470Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC212 reports
- Hurricane™ RX M00545940Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC2 recalls109 reports
- MUSTANG™ H74939171100470Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC203 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page