Palmaz Genesis PG3910BRecalls & reported problems
Cordis US Corp. · STENT GENESIS XD 39MM · Class 2 · Implant
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 20705032057544), received between Jan 2, 2018 and Jan 2, 2018 — classified as 1 injury.
The most frequently reported specific device problem is “Defective Component” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Defective Component1
- Device Dislodged or Dislocated1
- Physical Resistance1
Patient problems
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryJan 2, 2018Defective Component; Physical Resistance; Device Dislodged or Dislocated; Defective Component; Physical Resistance; Device Dislodged or Dislocated
DURING USE IN PATIENT, IT WAS REPORTED THAT A PALMAZ STENT WAS MOUNTED ON A NON CORDIS BALLOON CATHETER AND AN ATTEMPT WAS MADE TO ADVANCE THE DEVICES THROUGH A 8F NON CORDIS SHEATH. AFTER SEVERAL ATTEMPTS, THE PHYSICIAN FORCE THE DEVICE THROUGH THE SHEATH AND THE STENT WAS PROXIMAL TO THE BALLOON AND IT WAS IMPOSSIBLE TO DILATE IT. THE PHYSICIAN TRIED TO PASS A SMALLER 0.035" BALLOON THROUGH THE STENT INSIDE THE PATIENT, BUT HE WAS ONLY PUSHING IT UPWARDS. AFTER SEVERAL ATTEMPTS, THE PHYSICIAN TRIED TO SNARE THE STENT AND REMOVE IT FROM THE PATIENT. DURING THIS MANEUVER, THE STENT DROPPED AND LANDED IN THE POPLITEAL ARTERY. THE PROCEDURE WAS COMPLETED USING A NON CORDIS 10 X 40 MM STENT BY OVER EXPANDING IT TO 12 MM. THE STENT COULDN¿T BE REMOVED AND THE PATIENT HAD TO BE HOSPITALIZED WHILE HE NEEDED A SURGICAL REMOVAL OF THE STENT. THE PHYSICIAN COMPLAINS ABOUT THE LABELING, THAT NOWHERE THE SHEATH FITTING OF THE STENT WAS WRITTEN ON THE LABEL. HE DOUBTS THAT THIS STENT PASSES 8F, AS HE HAD TO FORCE HARDLY.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 7157986 ↗
Other CATHETER, BILIARY, DIAGNOSTIC devices
- Hurricane™ RX M00545900Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC2 recalls1 death705 reports
- MUSTANG™ H74939171060470Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC384 reports
- CRE™ PRO M00558710Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC1 recall284 reports
- Hurricane™ RX M00545920Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC2 recalls211 reports
- MUSTANG™ H74939171070470Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC265 reports
- MUSTANG™ H74939171050470Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC212 reports
- Hurricane™ RX M00545940Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC2 recalls109 reports
- MUSTANG™ H74939171100470Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC203 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page