POWERFLEX 4400606XRecalls & reported problems
Cordis US Corp. · POWERFLEXPRO 6MM6CM 135 · Class 2
All models of POWERFLEX (56)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 20705032059548), received between Jan 17, 2019 and Oct 25, 2021 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Deflation Problem” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Deflation Problem1
- Material Integrity Problem1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionOct 25, 2021Deflation Problem; Deflation Problem
DURING USE IN PATIENT, THE POWERFLEX PRO 6X6 CM X135 CM 5FR 0.035" BALLOON WOULD NOT DEFLATE COMPLETELY CAUSING DIFFICULTY OF THE BALLOON TO BE REMOVED FROM THE COMPETITOR'S SHEATH. THERE WAS NO PATIENT INJURY. THE PHYSICIAN REMOVED THE SHEATH WITH THE BALLOON INSIDE AND COMPLETED THE PROCEDURE. THE POWERFLEX PRO BALLOON WAS PREPPED PER THE INSTRUCTION FOR USE WITH NO ANOMALIES NOTED DURING PREP. THERE WERE NO DIFFICULTY REMOVING THE PRODUCT FROM THE HOOP, PROTECTIVE BALLOON COVER, STYLET OR ANY OF THE STERILE PACKAGING COMPONENTS. A CONSTANT AND DEDICATED SALINE SOURCE WAS UTILIZED THROUGH THE BALLOON DURING INSERTION DURING PREP. THERE WERE NO KINKS OR OTHER DAMAGES NOTED PRIOR TO INSERTING THE PRODUCTS INTO THE PATIENT. THE BALLOON WAS ABLE TO ENTERED THE 6 FR COMPETITOR'S SHEATH WELL, BUT THEN IT WAS NOT POSSIBLE TO REMOVE THE BALLOON FROM THE SHEATH AS THERE WAS A PROBLEM WITH DEFLATING THE BALLOON COMPLETELY. THE PHYSICIAN REMOVED BOTH THE SHEATH WITH THE BALLOON INSERTED FROM THE PATIENT AND ANOTHER COMPETITOR'S SHEATH WAS USED TO CONTINUE THE PROCEDURE. THE DEVICE IS AVAILABLE FOR ANALYSIS. NO OTHER INFORMATION WAS PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12689740 ↗MalfunctionJan 17, 2019Material Integrity Problem; Material Integrity Problem
THE REPORT RECEIVED FROM THE AFFILIATE INDICATED THE 6MM6CM 135 POWERFLEX PRO PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY (PTA) BALLOON CATHETER WAS TORN. ANALYSIS OF THE RETURNED DEVICE INDICATES BALLOON BURST. THERE WAS NO PATIENT INJURY.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8256927 ↗
Other Catheter, angioplasty, peripheral, transluminal devices
- Coyote™ ES H74939135152010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal879 reports
- Coyote™ ES H74939135204010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal585 reports
- Coyote™ ES H74939135202010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal437 reports
- Coyote™ ES H74939135304010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal384 reports
- Coyote™ ES H74939135404010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal293 reports
- Coyote™ ES H74939134152010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal279 reports
- Coyote™ H74939185202210Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal200 reports
- Coyote™ ES H74939135254010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal127 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page