SMART FLEX SF06060MBRecalls & reported problems

Cordis US Corp. · SMART FLEX 6x60 BIL, 120cm · Class 2 · Implant

All models of SMART FLEX (22)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 20705032066041), received between Jun 23, 2023 and Jun 23, 2023 — classified as 1 injury.

The most frequently reported specific device problem is “Difficult or Delayed Positioning” (1 report).

7 other recalls cover devices cleared under the same FDA submission (K121125); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Most reported problems

Device problems

  • Difficult or Delayed Positioning1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryJun 23, 2023Difficult or Delayed Positioning; Difficult or Delayed Positioning

    AS REPORTED, THE CATHETER SHAFT OF A SMART FLEX 6X60 SELF-EXPANDING STENT DELIVERY SYSTEM SNAPPED WHILE BEING DELIVERED TO THE TREATMENT SITE CAUSING ¿GEOGRAPHIC MISS¿ WITH THE STENT AS IT HAD TO BE DEPLOYED PREMATURELY TO AVOID RISK TO PATIENT. THE DEPLOYMENT SHAFT DISTAL TO THE TUOHY-BORST WAS KINKED/BENT RESULTING IN INABILITY TO ADVANCE THE STENT AND NECESSITY OF DEPLOYMENT WHERE IT WAS CURRENTLY. THE TOTALITY OF THE LESION WAS NOT COVERED BY THE STENT, AS IT SHOULD HAVE BEEN. A SECOND STENT WAS THEN PLACED TO COVER THE REST OF THE LESION. THERE WAS NO REPORTED PATIENT INJURY. THERE WAS MINIMAL RESISTANCE/FRICTION DURING INSERTION OF THE DEVICE. THE DELIVERY OF THE SDS TO THE LESION WAS CONTRALATERAL. MODERATE DIFFICULTY WAS ENCOUNTERED WHILE ADVANCING/TRACKING THE SDS TOWARDS THE LESION. THE INTENDED PROCEDURE WAS REPORTED TO BE STENTING OF THE SUPERFICIAL FEMORAL ARTERY (SFA). THE TARGET LESION WAS REPORTED AS A RECALCITRANT PLAQUE IN THE SFA. THE LESION WAS NOT CALCIFIED AND NOT TORTUOUS. THE DEVICE WAS STORED, HANDLED, AND PREPPED AS PER THE INSTRUCTIONS FOR USE (IFU) WITH NO DIFFICULTY IN PREPPING THE DEVICE. THE TEMPERATURE EXPOSURE INDICATOR ON THE POUCH WAS CHECKED TO C

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17192898 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K121125. One submission often covers many models, so check the product and lot details in each record.

  • Z-0218-2022 · Oct 1, 2021 · Open, Classified
    SMART FLEX 6x150 BIL, 120cm The S.M.A.R.T. Flex Biliary Stent System is indicated for use in the palliation of malignant strictures in the biliary tree.
  • Z-0217-2022 · Oct 1, 2021 · Open, Classified
    SMART FLEX 6x120 BIL, 120cm The S.M.A.R.T. Flex Biliary Stent System is indicated for use in the palliation of malignant strictures in the biliary tree.
  • Z-0220-2022 · Oct 1, 2021 · Open, Classified
    SMART FLEX 10x100 BIL, 80cm The S.M.A.R.T. Flex Biliary Stent System is indicated for use in the palliation of malignant strictures in the biliary tree.
  • Z-0219-2022 · Oct 1, 2021 · Open, Classified
    SMART FLEX 8x60 BIL, 80cm The S.M.A.R.T. Flex Biliary Stent System is indicated for use in the palliation of malignant strictures in the biliary tree.
  • Z-0221-2022 · Oct 1, 2021 · Open, Classified
    SMART FLEX 10x100 BIL, 120cm The S.M.A.R.T. Flex Biliary Stent System is indicated for use in the palliation of malignant strictures in the biliary tree.
  • Z-0216-2022 · Oct 1, 2021 · Open, Classified
    SMART FLEX 9x60 BIL, 80cm The S.M.A.R.T. Flex Biliary Stent System is indicated for use in the palliation of malignant strictures in the biliary tree.
  • Z-0324-2018 · Nov 15, 2017 · Terminated
    Cordis S.M.A.R.T. Flex Biliary Stent System Product Usage: Is indicated for use in the palliation of malignant strictures in the biliary tree.

Other Stents, drains and dilators for the biliary ducts devices