SABER 48006015XRecalls & reported problems
Cordis Corporation · SABER 6MM15CM 150 · Class 2
All models of SABER (40)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 10
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 10 adverse event reports that list this exact device (DI 20705032069622), received between Dec 12, 2019 and Feb 24, 2026 — classified as 10 malfunctions.
The most frequently reported specific device problem is “Burst Container or Vessel” (5 reports).
1 other recall cover devices cleared under the same FDA submission (K133843); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Burst Container or Vessel5
- Deflation Problem1
- Detachment of Device or Device Component1
- Difficult to Remove1
- Leak/Splash1
- Material Rupture1
Patient problems
- No Clinical Signs, Symptoms or Conditions9
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 10 most recent of 10 reports, in the reporter's own words as published by the FDA.
MalfunctionFeb 24, 2026Leak/Splash
AS REPORTED, THE PHYSICIAN WAS USING A 6MM 15CM .018 SABER PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY (PTA) BALLOON. AFTER HIS 4TH INFLATION IN THE PATIENT'S RIGHT LEG (CFA/SFA) THE BALLOON HAD DEVELOPED A SMALL LEAK. THIS WAS DISCOVERED WHEN THE BALLOON WAS DEFLATED AND SLIGHTLY BLOODY SALINE CAME BACK INTO THE INFLATION DEVICE THAT WE BEING USED. THE SAME DEVICE WAS USED TO COMPLETE THE PROCEDURE. AFTER BLOOD WAS OBSERVED IN THE INFLATION DEVICE, THE BALLOON WAS REMOVED AND THE PROCEDURE CONCLUDED SUCCESSFULLY, WITH THE PATIENT REMAINING STABLE. THE PRODUCT WAS STORED PROPERLY ACCORDING TO THE INSTRUCTIONS FOR USE (IFU). NO DIFFICULTIES NOTED DURING REMOVAL FROM THE HOOP, PROTECTIVE BALLOON COVER, STYLET, OR OTHER STERILE PACKAGING COMPONENTS. NO KINKS OR DAMAGES WERE OBSERVED PRIOR TO INSERTION, AND THE DEVICE WAS PREPPED CORRECTLY, MAINTAINING NEGATIVE PRESSURE. THE INTENDED PROCEDURE TARGETED THE COMMON FEMORAL ARTERY (CFA), SUPERFICIAL FEMORAL ARTERY (SFA), AND POPLITEAL ARTERY (POP). NO RESISTANCE OR FRICTION WAS NOTED DURING INSERTION THROUGH THE ROTATING HEMOSTATIC VALVE. THE DEVICE WILL NOT BE RETURNED FOR EVALUATION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24431573 ↗MalfunctionAug 29, 2025Burst Container or Vessel; Burst Container or Vessel
A REPORTED, THERE WAS AN ISSUE WITH THE HYPOTUBE ON A 2MM X 150MM SABER .014 PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY (PTA) BALLOON CATHETER AND THE DEVICE WOULD NOT TRACK UP A NON-CORDIS GUIDEWIRE AND INTO THE PATIENT. RESISTANCE WAS EXPERIENCED INSIDE THE BALLOON AREA OF THE SABER .014 BALLOON CATHETER, PREVENTING IT FROM GOING ON THE WIRE NORMALLY WHEN INSERTING FROM THE DISTAL TIP. ADDITIONALLY, THERE WAS SOME DIFFICULTY FLUSHING THE GUIDEWIRE LUMEN, BUT IT WAS NOT BLOCKED WITH INJECTABLE MATERIAL. A NEW CORDIS BALLOON CATHETER WAS OPENED AND USED. THE SAME GUIDEWIRE WAS SUCCESSFULLY USED WITH THE REPLACEMENT BALLOON CATHETER WITHOUT ISSUE. LATER IN THE PROCEDURE, A 6MM X 15CM SABER PTA BALLOON CATHETER WAS OPENED; HOWEVER, THE BALLOON BURST ON CALCIUM. A NEW CORDIS BALLOON CATHETER WAS USED AS A REPLACEMENT AND THERE WERE NO REPORTED INJURIES TO THE PATIENT. THIS WAS DURING A PROCEDURE TO TREAT CHRONIC TOTAL OCCLUSION (CTO) WITH CALCIUM THROUGHOUT, THOUGH NOT SEVERE. THE SABER .014 DEVICE WAS STORED AND PREPPED ACCORDING TO THE INSTRUCTIONS FOR USE (IFU). THE SABER .018 DEVICE WAS ALSO STORED AND PREPPED PER THE IFU, WITH NO DIFFICULTY REMOVING STERILE PACKAGING COMPONENTS. THE S
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22921087 ↗MalfunctionApr 2, 2025Detachment of Device or Device Component; Detachment of Device or Device Component
AS REPORTED, THE GUIDEWIRE DELIVERY LUMEN AT THE TIP END OF THE BALLOON ON A 6MM X 15CM SABER PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY (PTA) DILATION CATHETER IS A FRACTION SHORTER. THERE WERE NO REPORTS OF PATIENT INJURY. MULTIPLE ATTEMPTS TO OBTAIN SUPPLEMENTAL INFORMATION WERE MADE; HOWEVER, ADDITIONAL EVENT DETAILS WERE NOT PROVIDED. THE DEVICE WAS RETURNED FOR EVALUATION. THE UNIT WAS THOROUGHLY INSPECTED OBSERVING A SEPARATION CONDITION AT THE DISTAL TIP.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21755156 ↗MalfunctionJul 23, 2024Burst Container or Vessel; Burst Container or Vessel
AS REPORTED, THE 6MM 15CM SABER PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY (PTA) BALLOON RUPTURED AT/BELOW RBP DURING THE LOWER LIMB ARTERY SURGERY. THEREFORE, THE SURGERY COULD NOT BE PERFORMED. THE DEVICE WAS REMOVED INTACT FROM THE PATIENT. THE CASE WAS COMPLETED WITH A NEW SABER BALLOON. THERE WAS NO REPORTED INJURY TO THE PATIENT. THE DEVICE WAS STORED PROPERLY PER THE INSTRUCTIONS FOR USE (IFU). THERE WAS NO DIFFICULTY REMOVING THE PRODUCT FROM THE HOOP, REMOVING THE PROTECTIVE BALLOON COVER, STYLET, OR ANY OF THE STERILE PACKAGING COMPONENTS. THERE WERE NO KINKS OR DAMAGES NOTED PRIOR TO INSERTING THE DEVICE INTO THE PATIENT. THE DEVICE WAS PREPPED PER THE IFU. THE DEVICE WAS PREPPED NORMALLY AND WAS ABLE TO MAINTAIN NEGATIVE PRESSURE. THE INTENDED LESION WAS AT THE OPENING OF THE SUPERFICIAL FEMORAL ARTERY WHICH HAD A TOTAL OCCLUSION. THE LESION HAD SEVERE CALCIFICATION. THE CONTRAST/SALINE RATIO WAS 50/50. THE DEVICE WILL BE RETURNED FOR EVALUATION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19804882 ↗MalfunctionJun 14, 2024Deflation Problem; Deflation Problem
AS REPORTED, AFTER DILATION OF A 6MM X 150CM SABER PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY (PTA) BALLOON CATHETER, IT WAS DIFFICULT TO REVERT THE BALLOON BACK TO ITS ORIGINAL STATE. AN ATTEMPT TO REINFLATE THE BALLOON WAS MADE, BUT THE BALLOON COULD NOT FILL COMPLETELY. THE DEVICE WAS REMOVED, AND AN UNKNOWN DEVICE WAS USED TO COMPLETE THE PROCEDURE. THERE WERE NO REPORTED INJURIES TO THE PATIENT. THIS WAS DURING A PROCEDURE IN WHICH A RETROGRADE PUNCTURE WAS MADE IN THE LEFT FEMORAL ARTERY. AN ANGIOGRAM WAS PERFORMED WHICH SHOWED OCCLUSION OF THE LEFT SUPERFICIAL FEMORAL ARTERY (SFA). ADDITIONAL INFORMATION WAS REQUESTED BUT WAS NOT PROVIDED. THE DEVICE WILL BE RETURNED FOR EVALUATION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19538956 ↗MalfunctionMar 15, 2023Burst Container or Vessel; Burst Container or Vessel
AS REPORTED, THE BALLOON OF A 6MM X 15CM 150CM SABER PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY (PTA) BALLOON CATHETER POPPED AFTER AN INFLATION TO 11AMOSPHERES (ATM) WITHIN AN UNKNOWN CORDIS STENT WHICH WAS PLACED IN THE SUPERFICIAL FEMORAL ARTERY (SFA). AS A RESULT, A 6MM X 10CM SABER PTA BALLOON CATHETER WAS USED AS A REPLACEMENT. POST DILATION OF THE UNKNOWN CORDIS STENT WAS PERFORMED, AND THE PROCEDURE WAS SUCCESSFULLY COMPLETED. THERE WAS NO REPORTED INJURY TO THE PATIENT. THIS WAS DURING A PERIPHERAL INTERVENTIONAL PROCEDURE TO TREAT A 100% STENOSED, CHRONIC TOTALLY OCCLUDED (CTO) LESION IN THE SFA. THE LESION DID NOT HAVE ANY CALCIFICATION OR TORTUOSITY PRESENT. THE DEVICE WAS STORED AND PREPPED PER THE INSTRUCTIONS FOR USE (IFU) AND MAINTAINED NEGATIVE PRESSURE DURING PREPARATION. THERE WAS NO DIFFICULTY REMOVING THE STYLET OR ANY OF THE STERILE PACKAGING COMPONENTS. THE BALLOON WAS PREPPED WITH A 50/50 CONTRAST AND SALINE MIXTURE. THERE WAS NO DIFFICULTY ADVANCING THE DEVICE THOUGH THE IMPLANTED STENT. THE DEVICE WAS ABLE TO BE REMOVED EASILY FROM THE PATIENT AND REMAINED IN ONE PIECE DURING ITS REMOVAL. THE DEVICE WILL BE RETURNED FOR EVALUATION. ADDENDUM: PRODUCT EVALUATION
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16544614 ↗MalfunctionOct 7, 2022Difficult to Remove; Difficult to Remove
AS REPORTED, AFTER THE SUCCESSFUL INFLATION OF A 6MM X 15CM 150CM SABER PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY (PTA) BALLOON CATHETER, THE DEVICE BECAME STUCK INSIDE OF AN UNKNOWN CATHETER SHEATH INTRODUCER (CSI) AND WAS UNBALE TO BE REMOVED. IT WAS REPORTED THAT EVERYTHING HAD TO BE REMOVED, INCLUDING THE UNKNOWN CSI, IN ORDER TO REMOVE THE SABER PTA BALLOON CATHETER FROM THE PATIENT. THE SABER BALLOON CATHETER WAS THEN CUT SO IT COULD BE REMOVED FROM THE SHEATH. THERE WAS NO REPORTED INJURY TO THE PATIENT. ADDITIONAL INFORMATION WAS REQUESTED BUT WAS NOT PROVIDED, AND THE DEVICE WAS NOT RETURNED AS EXPECTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15565756 ↗MalfunctionSep 24, 2022Burst Container or Vessel; Burst Container or Vessel
AS REPORTED, DURING THE INFLATION OF 6MM X 15CM 150CM SABER PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY (PTA) BALLOON CATHETER TO ITS CORRECT PRESSURE, THE BALLOON RUPTURED. A SECOND 6MM X 15M 150CM SABER PTA BALLOON CATHETER WAS USED; HOWEVER, THE BALLOON OF THE SECOND SABER PTA BALLOON CATHETER RUPTURED DURING AN INFLATION TO ITS CORRECT PRESSURE AS WELL. A 6MM X 15CM 135CM POWERFLEX PRO PTA BALLOON CATHETER WAS THEN USED AND WAS ABLE TO CROSS THE LESION SUCCESSFULLY. THE POWERFLEX PRO PTA BALLOON CATHETER WAS REMOVED FOR AN UNDISCLOSED REASON, AND AN ATTEMPT TO RE-INSERT THE DEVICE WAS MADE. PRIOR TO RE-INSERTION OF THE DEVICE, KINKING WAS OBSERVED ON THE DEVICE, AND IT WAS DECIDED NOT TO RE-INSERT THE POWERFLEX PRO PTA BALLOON CATHETER. AS A RESULT, AN UNKNOWN BALLOON CATHETER WAS USED. THERE WAS NO REPORTED INJURY TO THE PATIENT. THE DEVICES WERE ALL STORED CORRECTLY AND WERE BEING HANDED BY AN EXPERIENCED USER. ADDITIONAL INFORMATION WAS REQUESTED BUT WAS NOT PROVIDED. THE DEVICES WILL BE RETURNED FOR EVALUATION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15479833 ↗MalfunctionSep 24, 2022Burst Container or Vessel; Burst Container or Vessel
AS REPORTED, DURING THE INFLATION OF 6MM X 15CM 150CM SABER PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY (PTA) BALLOON CATHETER TO ITS ¿CORRECT PRESSURE¿, THE BALLOON RUPTURED. A SECOND 6MM X 15M 150CM SABER PTA BALLOON CATHETER WAS USED; HOWEVER, THE BALLOON OF THE SECOND SABER PTA BALLOON CATHETER RUPTURED DURING AN INFLATION TO ITS ¿CORRECT PRESSURE¿ AS WELL. A 6MM X 15CM 135CM POWERFLEX PRO PTA BALLOON CATHETER WAS THEN USED AND WAS ABLE TO CROSS THE LESION SUCCESSFULLY. THE POWERFLEX PRO PTA BALLOON CATHETER WAS REMOVED FOR AN UNDISCLOSED REASON, AND AN ATTEMPT TO RE-INSERT THE DEVICE WAS MADE. PRIOR TO RE-INSERTION OF THE DEVICE, KINKING WAS OBSERVED ON THE DEVICE, AND IT WAS DECIDED NOT TO RE-INSERT THE POWERFLEX PRO PTA BALLOON CATHETER. AS A RESULT, AN UNKNOWN BALLOON CATHETER WAS USED. THERE WAS NO REPORTED INJURY TO THE PATIENT. THE DEVICES WERE ALL STORED CORRECTLY AND WERE BEING HANDED BY AN EXPERIENCED USER. ADDITIONAL INFORMATION WAS REQUESTED BUT WAS NOT PROVIDED. THE DEVICES WILL BE RETURNED FOR EVALUATION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15479182 ↗MalfunctionDec 12, 2019Material Rupture; Material Rupture
DURING PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY (PTA) OF A LESION IN THE SUPERFICIAL FEMORAL ARTERY (SFA), A THE 6MM X 15CM X 150CM SABER PTA BALLOON CATHETER RUPTURED. THERE WAS NO PATIENT INJURY AND THE DEVICE WILL BE RETURNED FOR ANALYSIS. THE DEVICE WAS OPENED IN A STERILE FIELD.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9458615 ↗
FDA clearance and classification
Cleared through 510(k) K133843 on Jun 27, 2014 (decision: Substantially Equivalent). Submitted by Cordis Corporation as “Saber Percutaneous Transluminal Angioplasty Dilatation Catheter”. The FDA review took 191 days. FDA record ↗
The FDA regulates product code LIT (catheter, angioplasty, peripheral, transluminal) under 21 CFR 870.1250 as a Class II device. 21 CFR 870.1250 ↗
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Recalls under the same FDA submission
These recalls involve devices cleared under K133843. One submission often covers many models, so check the product and lot details in each record.
- Z-2235-2021 · Jul 19, 2021 · TerminatedCordis SABER PTA Balloon Dilation Catheter, 4F, REF 48004010X
Common questions about the SABER 48006015X
Has the SABER 48006015X been recalled?
No FDA recall record in our data names this exact device identifier (DI 20705032069622), based on the FDA recall file dated Nov 27, 2026. However, 1 recall involves devices cleared under the same FDA submission. It may or may not include this model, so check the product, model and lot details in that record.
What problems have been reported with the SABER 48006015X?
The FDA's MAUDE database lists 10 adverse event reports for this device, received between Dec 12, 2019 and Feb 24, 2026. In those reports, the most common specific device problems are “Burst Container or Vessel” (5), “Deflation Problem” (1) and “Detachment of Device or Device Component” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the SABER 48006015X?
None of the reports are classified as deaths, 0 as injuries and 10 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the SABER 48006015X FDA approved?
It was cleared through 510(k) K133843 on Jun 27, 2014. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.
Who makes the SABER 48006015X, and is it still sold?
The FDA's device database lists Cordis Corporation as the company responsible for it (brand SABER, model 48006015X). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Catheter, angioplasty, peripheral, transluminal devices
- Coyote™ ES H74939135152010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal880 reports
- Coyote™ ES H74939135204010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal585 reports
- Coyote™ ES H74939135202010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal439 reports
- Coyote™ ES H74939135304010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal383 reports
- Coyote™ ES H74939135404010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal293 reports
- Coyote™ ES H74939134152010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal280 reports
- Coyote™ H74939185202210Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal200 reports
- Coyote™ ES H74939135254010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal128 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page