SABER 48004010SRecalls & reported problems
Cordis Corporation · SABER 4MM10CM 90 · Class 2
All models of SABER (40)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 9
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 9 adverse event reports that list this exact device (DI 20705032069783), received between Nov 29, 2017 and Dec 2, 2024 — classified as 1 injury, 8 malfunctions.
The most frequently reported specific device problem is “Burst Container or Vessel” (6 reports).
1 other recall cover devices cleared under the same FDA submission (K133843); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Burst Container or Vessel6
- Leak/Splash3
Patient problems
- No Clinical Signs, Symptoms or Conditions6
- No Consequences Or Impact To Patient2
- Perforation of Vessels1
Recent adverse event reports
The 9 most recent of 9 reports, in the reporter's own words as published by the FDA.
MalfunctionDec 2, 2024Burst Container or Vessel; Burst Container or Vessel
AS REPORTED, WHEN INFLATING THE BALLOON OF A 4MM X 10CM SABER PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY (PTA) BALLOON CATHETER, THE PRESSURE COULD NOT BE RAISED TO 6 ATMOSPHERES (ATM) AND A RUPTURE WAS SUSPECTED. THE BALLOON WAS DEFLATED, BUT SOME BLOOD HAD WITHDRAWN, AND THE RUPTURE WAS CONFIRMED. A NON-CORDIS BALLOON CATHETER WAS USED AS A REPLACEMENT TO COMPLETE THE PROCEDURE. THERE WERE NO REPORTED INJURIES TO THE PATIENT. THIS WAS DURING AN ARTERIOVENOUS (AV) SHUNT PTA PROCEDURE. THE TARGET SITE VESSEL CHARACTERISTICS INCLUDED MODERATE CALCIFICATION, SEVERE TORTUOSITY, AND 70% STENOSIS. THE DEVICE WAS STORED AND PREPPED PER THE INSTRUCTIONS FOR USE (IFU). THERE WAS NO DIFFICULTY REMOVING THE STYLET OR ANY OF THE STERILE PACKAGING COMPONENTS. THE DEVICE MAINTAINED NEGATIVE PRESSURE DURING PREPARATION. A NON-CORDIS 5F SHEATH WAS USED. THE DEVICE WILL NOT BE RETURNED FOR EVALUATION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20821105 ↗MalfunctionApr 21, 2023Burst Container or Vessel; Burst Container or Vessel
AS REPORTED, THE BALLOON OF A 4 MM X 10 CM 90 CM SABER PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY (PTA) DILATION CATHETER WAS USED BUT RUPTURED. THE COMPLAINT DEVICE WAS REPLACED WITH AN UNKNOWN SLALOM THRILL BALLOON CATHETER AND THE PROCEDURE COMPLETED. THERE WAS NO PATIENT INJURY. THE PROCEDURE WAS A SHUNT PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY (PTA) CASE. THE DEVICE WILL NOT BE RETURNED FOR EVALUATION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16784693 ↗MalfunctionMar 9, 2023Burst Container or Vessel; Burst Container or Vessel
AS REPORTED, A 4MM X 10 CM SABER PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY (PTA) BALLOON CATHETER WAS USED BUT RUPTURED BEFORE REACHING ITS NOMINAL PRESSURE. THERE WAS NO REPORTED PATIENT INJURY. THE COMPLAINT PRODUCT WAS BEING USED IN A SHUNT PTA CASE. THE DEVICE WAS DISCARDED; THEREFORE, IT WILL NOT BE RETURNED FOR EVALUATION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16518779 ↗MalfunctionSep 5, 2022Leak/Splash; Leak/Splash
AS REPORTED, THE BALLOON OF THE SABER 4MM 10CM COULD NOT BE RAISED TO NOMINAL PRESSURE (8ATM). THE BALLOON WAS REMOVED FROM THE PATIENT, THE BALLOON WAS EXPANDED OUTSIDE THE BODY, AND IT WAS NOTICED THAT THE BALLOON HAD LEAKAGE FROM A PINHOLE. THE TREATMENT WAS SUCCESSFUL AFTER IT WAS REPLACED WITH A NEW NON-CORDIS BALLOON CATHETER OF THE SAME SIZE. THERE WAS NO REPORTED INJURY TO THE PATIENT. THE PROCEDURE WAS TO TREAT STENOTIC LESIONS IN THE LEFT SUPERFICIAL FEMORAL ARTERY, POPLITEAL ARTERY, AND PULMONARY ARTERY. A 5F NON-CORDIS SHEATH WAS INSERTED THROUGH THE LEFT COMMON FEMORAL ARTERY WITH AN IPSILATERAL ANTEGRADE PUNCTURE. THE SHEATH CROSSED THE LESION ALONG WITH THE DEVICE. THEY BOTH PASSED THROUGH THE LESION AND WAS PREPARED TO USE FOR POP LESION DILATION. PRESSURE WAS APPLIED WITH THE INFLATION DEVICE. THE DEVICE WILL BE RETURNED FOR EVALUATION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15354273 ↗MalfunctionSep 17, 2021Leak/Splash; Leak/Splash
AS REPORTED, A 4MM X 10CM X 90CM SABER PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY (PTA) BALLOON CATHETER WAS USED AND INFLATED, HOWEVER, IT WAS CONFIRMED THAT THE CONTRAST MEDIA WAS LEAKING. THEREFORE, THE PHYSICIAN STOPPED USING THE DEVICE. THERE WAS NO REPORTED PATIENT INJURY. THIS WAS A SHUNT PTA CASE. MULTIPLE ATTEMPTS WERE MADE WITHOUT SUCCESS TO OBTAIN THE DEVICE. ADDITIONAL INFORMATION WAS REQUESTED; HOWEVER, THE INFORMATION WAS NOT OBTAINED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12488041 ↗MalfunctionAug 24, 2021Leak/Splash; Leak/Splash
AS REPORTED, A 4MM X 10CM X 90CM SABER PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY (PTA) BALLOON CATHETER, HOWEVER, CONTRAST MEDIA LEAKAGE WAS CONFIRMED FROM ITS PROXIMAL SHAFT PART. THEREFORE, IT WAS REPLACED WITH A SAME SIZE NEW UNKNOWN BALLOON CATHETER AND THE PROCEDURE WAS COMPLETED. THERE WAS NO REPORTED PATIENT INJURY. THIS WAS A SHUNT PTA CASE. MULTIPLE ATTEMPTS WERE MADE WITHOUT SUCCESS TO OBTAIN THE DEVICE. ADDITIONAL INFORMATION WAS REQUESTED BUT WAS NOT OBTAINED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12362282 ↗InjuryNov 11, 2020Burst Container or Vessel; Burst Container or Vessel
THE PHYSICIAN CONFIRMED THAT THE 4MM X 10CM X 90CM SABER RAPID EXCHANGE (RX) BALLOON CATHETER (BC) RUPTURED, THE CONTRAST MEDIUM WAS LEAKING FROM THE BLOOD VESSELS AND THERE WAS ALSO VASCULAR RUPTURING. AFTER THAT, HEMOSTASIS WAS ACHIEVED, AND IT WAS CONFIRMED THAT VESSEL WAS BLOCKED. THIS WAS A SHUNT PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY (PTA) CASE. THE DEVICE WAS USED TO PERFORM PLAIN OLD BALLOON ANGIOPLASTY (POBA) THREE (3) TIMES AND THE PRESSURE WAS WITHIN ITS NOMINAL PRESSURE. THERE WAS RESIDUAL STENOSIS SO, THE PHYSICIAN INFLATED SABER TO RATED BALLOON PRESSURE TWICE. AT THE SECOND TIME (FIFTH TIME IN TOTAL), S/HE FELT THAT THE CONTRAST MEDIUM HAD COME OFF. ORIGINALLY IT WAS A DEFECT OF THE CHRONIC TOTAL OCCLUSIONS (CTO¿S) NON-GROWING SHUNT, BUT IT WAS THE PHYSICIAN¿S IMPRESSION THAT IT WAS OPENED AFTER PERFORMING THE THREE POBA AND WAS OCCLUDED AFTER THE VASCULAR RUPTURE BY BALLOON'S RUPTURE. SABER DEVICE RUPTURED IN A LESION WITH NO CALCIFICATION AND NO VASCULAR TORTUOSITY. IT WAS INFLATED WITHIN RATED BALLOON PRESSURE THAT WAS 18 ATMOSPHERIC PRESSURE (ATM). THE DEVICE WILL BE RETURNED FOR ANALYSIS.
Patient problems: Perforation of Vessels
MAUDE report 10824987 ↗MalfunctionJul 17, 2020Burst Container or Vessel; Burst Container or Vessel
AS REPORTED, THE BALLOON OF 4MM X 10CM 90CM SABER PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY (PTA) WAS USED FOR PRE-DILATION BUT IT RUPTURED AT 6 ATMOSPHERE (ATM). THEREFORE, IT WAS REPLACED WITH ANOTHER UNKNOWN 5MM 10CM BALLOON CATHETER AND THE PROCEDURE WAS COMPLETED WITH DRUG-COATED BALLOON. THERE WAS NO REPORTED PATIENT INJURY. THE LESION WAS AT THE SUPERFICIAL FEMORAL ARTERY (SFA) WHICH HAD CALCIFICATION. AN IPSILATERAL APPROACH WAS MADE. THE SABER PTA WAS USED IN CONJUNCTION WITH A 6F 11CM BRITE TIP SHEATH AND A NON-CORDIS GUIDEWIRE. AN INTRAVASCULAR ULTRASOUND (IVUS) WAS USED TO CHECK THE LESION AND THE DEVICE. THE PRODUCT LOOKED NORMAL WHEN REMOVED FROM ITS PACKAGING. THE DEVICE WAS PREPPED NORMALLY (I.E. MAINTAINED NEGATIVE PRESSURE). THE ACCESS SITE WAS THE RIGHT FEMORAL ARTERY. THE VESSEL HAD MODERATE TORTUOSITY WITH 90% STENOSIS. THERE WAS NO DIFFICULTY REMOVING THE PRODUCT FROM THE HOOP, THE PROTECTIVE BALLOON COVER, OR THE STYLET OR ANY OF THE STERILE PACKAGING COMPONENTS. THERE WERE NO KINKS NOR OTHER DAMAGES NOTED PRIOR TO INSERTING THE PRODUCT INTO THE PATIENT. A NON-CORDIS INFLATION DEVICE WAS USED. THE SAME INDEFLATOR WAS USED SUCCESSFULLY WITH OTHER DEVICES. THERE WA
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10289583 ↗MalfunctionNov 29, 2017Burst Container or Vessel; Burst Container or Vessel
DURING A PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY (PTA) CASE, IT WAS REPORTED THAT THE SABER PTA BALLOON CATHETER WAS DELIVERED TO THE LESION AND INFLATED, HOWEVER IT RUPTURED ABOUT NOMINAL PRESSURE. THE BALLOON WAS REPLACED WITH A NON CORDIS BALLOON AND THE PROCEDURE FINISHED SUCCESSFULLY. THERE WAS NO REPORTED PATIENT INJURY. THE TARGET LESION WAS THE SHUNT PTA. THE PATIENT¿S VESSEL LEVEL OF TORTUOUSNESS AND CALCIFICATION WAS UNKNOWN. THE RATE OF STENOSIS WAS UNKNOWN.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 7067059 ↗
FDA clearance and classification
Cleared through 510(k) K133843 on Jun 27, 2014 (decision: Substantially Equivalent). Submitted by Cordis Corporation as “Saber Percutaneous Transluminal Angioplasty Dilatation Catheter”. The FDA review took 191 days. FDA record ↗
The FDA regulates product code LIT (catheter, angioplasty, peripheral, transluminal) under 21 CFR 870.1250 as a Class II device. 21 CFR 870.1250 ↗
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Recalls under the same FDA submission
These recalls involve devices cleared under K133843. One submission often covers many models, so check the product and lot details in each record.
- Z-2235-2021 · Jul 19, 2021 · TerminatedCordis SABER PTA Balloon Dilation Catheter, 4F, REF 48004010X
Common questions about the SABER 48004010S
Has the SABER 48004010S been recalled?
No FDA recall record in our data names this exact device identifier (DI 20705032069783), based on the FDA recall file dated Nov 27, 2026. However, 1 recall involves devices cleared under the same FDA submission. It may or may not include this model, so check the product, model and lot details in that record.
What problems have been reported with the SABER 48004010S?
The FDA's MAUDE database lists 9 adverse event reports for this device, received between Nov 29, 2017 and Dec 2, 2024. In those reports, the most common specific device problems are “Burst Container or Vessel” (6) and “Leak/Splash” (3); the most common patient problem is “Perforation of Vessels” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the SABER 48004010S?
None of the reports are classified as deaths, 1 as an injury and 8 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the SABER 48004010S FDA approved?
It was cleared through 510(k) K133843 on Jun 27, 2014. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.
Who makes the SABER 48004010S, and is it still sold?
The FDA's device database lists Cordis Corporation as the company responsible for it (brand SABER, model 48004010S). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Catheter, angioplasty, peripheral, transluminal devices
- Coyote™ ES H74939135152010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal880 reports
- Coyote™ ES H74939135204010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal585 reports
- Coyote™ ES H74939135202010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal439 reports
- Coyote™ ES H74939135304010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal383 reports
- Coyote™ ES H74939135404010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal293 reports
- Coyote™ ES H74939134152010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal280 reports
- Coyote™ H74939185202210Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal200 reports
- Coyote™ ES H74939135254010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal128 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page