Argo SPK475Recalls & reported problems

Conmed Corporation · 4.75 mm Argo Knotless SP Anchor · Class 2 · Implant

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
4
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 20845854649814), received between Aug 24, 2023 and Jul 9, 2025 — classified as 4 malfunctions.

The most frequently reported specific device problem is “Material Fragmentation” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 1 reportsDec 2024: 1 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 1 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Material Fragmentation3
  • Detachment of Device or Device Component1

Patient problems

  • No Clinical Signs, Symptoms or Conditions3
  • Foreign Body In Patient1

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJul 9, 2025Material Fragmentation; Material Fragmentation

    THE SALES REPRESENTATIVE REPORTED ON BEHALF OF THE CUSTOMER THAT THE DEVICE, SPK475, 4.75 MM ARGO KNOTLESS SP ANCHOR, WAS BEING USED DURING A ROTATOR CUFF PROCEDURE ON (B)(6) 2025 WHEN IT WAS REPORTED, ¿SURGEON INSERTED AND DEPLOYED IMPLANT AND THE METAL PORTION OF THE INSERTER REMAINED INSIDE THE ANCHOR. THE SURGEON WAS ABLE TO REMOVE THIS METAL PORTION WITH A SANP. SURGEON HAD TO USE A TOOL TO "YANK" BROKEN PART OUT OF THE PATIENT. PER SURGEON: "IT DONE BROKE".¿. THERE WAS NO REPORT OF INJURY, MEDICAL INTERVENTION, OR HOSPITALIZATION FOR THE USER OR PATIENT. THE PROCEDURE WAS COMPLETED WITHOUT AN ALTERNATE DEVICE CAUSING A 5-MINUTE DELAY. THIS REPORT IS BEING RAISED DUE TO THE REPORTED MALFUNCTION WITH POTENTIAL FOR INJURY UPON REOCCURRENCE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22456328 ↗
  • MalfunctionDec 2, 2024Detachment of Device or Device Component; Detachment of Device or Device Component

    THE DISTRIBUTOR REPORTED ON BEHALF OF THEIR CUSTOMER THAT THE DEVICE, SPK475, 4.75 MM ARGO KNOTLESS SP ANCHOR, WAS BEING USED DURING A ROTATOR REPAIR PROCEDURE ON (B)(6) 2024 WHEN IT WAS REPORTED, ¿THE TITANIUM PART IS DISMANTLED BY CUTTING THE SUTURE OF THE DEVICE.¿. FURTHER ASSESSMENT FOUND THAT THERE WAS A DETACHMENT OF COMPONENTS THAT WAS RETRIEVED USING PLIERS AFTER X-RAY. THIS CAUSED A 3-HOUR DELAY IN THE PROCEDURE; HOWEVER, THE PROCEDURE WAS COMPLETED USING ANOTHER SPK475 DEVICE. THERE WAS NO REPORT OF INJURY, MEDICAL INTERVENTION, OR HOSPITALIZATION FOR THE PATIENT. THIS REPORT IS BEING RAISED DUE TO THE REPORTED MALFUNCTION WITH POTENTIAL FOR INJURY UPON REOCCURRENCE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20817553 ↗
  • MalfunctionNov 18, 2024Material Fragmentation; Material Fragmentation

    THE DISTRIBUTOR REPORTED ON BEHALF OF THE CUSTOMER THAT THE SPK475, 4.75 MM ARGO KNOTLESS SP ANCHOR, DEVICE WAS BEING USED ON (B)(6) 2024 DURING A ROTATOR CUFF REPAIR PROCEDURE WHEN IT WAS REPORTED¿ THE ANCHOR BREAKS, THE PEEK FRAGMENT IS LOST INSIDE THE JOINT.". FURTHER ASSESSMENT QUESTIONING FOUND THAT ¿HE TRIED WITH SHAVER, WITH TWEEZERS AND FAILED TO REMOVE THE FRAGMENTS FROM THE JOINT. THE HOSPITAL HAS NOT REPORTED THE NOTIFICATION TO THE AUTHORITIES, AS I UNDERSTAND IT, BECAUSE THE FRAGMENT WAS SUCCESSFULLY REMOVED." ¿IT WAS ALSO REPORTED THAT "THEY KEPT THE FIRST IMPLANT; THE REST WAS REMOVED. "THE PROCEDURE WAS COMPLETED WITH A 3 HOUR DELAY AND THE USE OF THE SAME ALTERNATE DEVICE. THERE WAS NO REPORT OF MEDICAL INTERVENTION, EXTENDED HOSPITALIZATION FOR THE PATIENT. THE CURRENT STATUS OF THE PATIENT WAS REPORTED AS UNKNOWN. THIS REPORT IS BEING RAISED DUE TO THE REPORTED MALFUNCTION WITH POTENTIAL FOR INJURY UPON REOCCURRENCE.

    Patient problems: Foreign Body In Patient

    MAUDE report 20712196 ↗
  • MalfunctionAug 24, 2023Material Fragmentation; Material Fragmentation

    THE SALES REPRESENTATIVE REPORTED ON BEHALF OF THE CUSTOMER THAT THE SPK475, 4.75MM ARGO KNOTLESS SP ANCHOR, WAS BEING USED DURING AN UNKNOWN PROCEDURE ON (B)(6) 2023 WHEN IT WAS REPORTED, ¿DIDN'T WORK AS SHOULD. METAL TIP FELL OFF INSIDE PATIENT. PIECE WAS RETRIEVED. SURGERY COMPLETED WITH A REGULAR K475.¿. THERE WAS NO REPORT OF INJURY, MEDICAL INTERVENTION, OR HOSPITALIZATION FOR THE PATIENT OR USER. THE PROCEDURE WAS COMPLETED AS PLANNED WITH A SLIGHT DELAY WHILE RETRIEVING THE PIECE. THIS REPORT IS BEING RAISED DUE TO THE REPORTED MALFUNCTION WITH POTENTIAL FOR INJURY UPON REOCCURRENCE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17610118 ↗

Other Fastener, fixation, nondegradable, soft tissue devices

All Fastener, fixation, nondegradable, soft tissue devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page