Argo Knotless K475Recalls & reported problems

Conmed Corporation · 4.75 mm Argo Knotless Anchor · Class 2 · Implant

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 20845854649821), received between Nov 22, 2021 and Nov 13, 2025 — classified as 3 malfunctions.

The most frequently reported specific device problem is “Material Fragmentation” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 1 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 1 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Material Fragmentation3

Patient problems

  • No Clinical Signs, Symptoms or Conditions3

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • MalfunctionNov 13, 2025Material Fragmentation; Material Fragmentation

    THE SALES REPRESENTATIVE REPORTED ON BEHALF OF THE CUSTOMER THAT THE K475, 4.75 MM ARGO KNOTLESS ANCHOR WAS BEING USED ON (B)(6) 2025 DURING AN RCR AND THE ¿SURGEON WAS FINISHING HIS CUFF REPAIR USING A 4.75MM ARGO (K475 - 1443004). HE HAD PASSED X2 RIBBONS THOUGH THE CUFF FOR THE MEDIAL ROW AND THEN ANCHORED ALL 4 LIMBS OF RIBBON INTO THIS ARGO. HE HAD PRE-PUNCHED WITH A DISPOSABLE PUNCH (K4755DTBP - 1457856) WHICH WORKED WELL. HE REMOVED THE ARGO AFTER SCREWING THE ANCHOR IN WHICH WORKED GREAT. WHEN HE USED THE KATANA SUTURE CUTTER TO CUT THE LIMBS OF SUTURE, HE MOVED THE CAMERA BACK TO THE WORKING SITE WHERE HE COULD SEE THE KATANA WORKING AND NOTICED A FREE METAL PIECE. AT FIRST, HE THOUGHT THE KATANA HAD COME APART BUT IT WAS THE END OF THE ARGO THAT HAD DISLODGED FROM THE ANCHOR WHEN HE REMOVED THE HANDLE. HE WASN'T WORRIED. WE CHECKED THE REPAIR AND THE ANCHOR WAS WORKING WELL LIKE IT SHOULD. WE THEN MADE SURE THAT WAS ALL THAT WAS MISSING AND TOOK PHOTOS OF THE ANCHOR AND THE DISLODGED PIECE. PROCEDURE WAS COMPLETED WHEN THIS INCIDENT HAPPENED. WE ENSURED NO METAL WAS LEFT IN THE PATIENT." THERE WAS NO REPORT OF IMPACT OR INJURY TO THE PATIENT AND THIS EVENT DID NOT CAUSE A

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23541418 ↗
  • MalfunctionSep 26, 2024Material Fragmentation; Material Fragmentation

    THE SALES REPRESENTATIVE REPORTED ON BEHALF OF THE CUSTOMER, THAT K475, 4.75 MM ARGO KNOTLESS ANCHOR WAS BEING USED ON (B)(6) 2024 DURING A ROTATOR CUFF REPAIR PROCEDURE WHEN IT WAS REPORTED ¿WELD BROKE AND HEX WAS FLOATING AROUND IN THE SHOULDER, CAUSED 5¿10-MINUTE CASE DELAY.¿. FURTHER ASSESSMENT FOUND THAT THE FRAGMENT WAS REMOVED WITH THE USE OF GRASPERS. THE PROCEDURE WAS COMPLETED AND THERE WAS NO REPORT OF INJURY, MEDICAL INTERVENTION, OR EXTENDED HOSPITALIZATION FOR THE PATIENT OR USER. THIS REPORT IS BEING RAISED ON THE BASIS OF MALFUNCTION WITH POTENTIAL FOR INJURY UPON REOCCURRENCE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20309694 ↗
  • MalfunctionNov 22, 2021Material Fragmentation; Material Fragmentation

    THE SALES REPRESENTATIVE REPORTED ON BEHALF OF THE CUSTOMER THAT THE DEVICE, K475, 4.75MM ARGO KNOTLESS ANCHOR, WAS BEING USED ON APPROXIMATELY (B)(6) 2021 DURING A ROTATOR CUFF REPAIR PROCEDURE AND THE ¿TIP WAS BROKEN DURING ANCHOR INSERTION.¿ THERE WAS NO REPORT OF IMPACT OR INJURY TO THE PATIENT. THERE WAS MAYBE A 5 MINUTE DELAY TO LOCATE AND REMOVE THE PIECE AND THE PROCEDURE WAS COMPLETED WITH A BACKUP. AFTER FURTHER ASSESSMENT IT WAS FOUND, ¿THE TIP DID FALL INTO THE INCISION SITE, WE WERE ABLE TO RETRIEVE THE BROKEN TIP AND UPON INSPECTION IT WE WERE ABLE TO FIT BOTH PARTS BACK TOGETHER TO ENSURE THERE WERE NO OTHER SMALLER PIECES. THE PIECE WAS RETRIEVED USING A GRASP.¿ THIS REPORT IS BEING RAISED ON THE BASIS OF MALFUNCTION WITH POTENTIAL FOR INJURY UPON REOCCURRENCE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12858282 ↗

Other Fastener, fixation, nondegradable, soft tissue devices

All Fastener, fixation, nondegradable, soft tissue devices →