Skip to content

BD BBL™ Sensi-Disc™ Cefepime 30 µg 231696Recalls & reported problems

Becton, Dickinson And Company · BD BBL™ Sensi-Disc™ Cefepime 30 µg · Class 2

Data updated Oct 18, 2026 from official FDA records · Editorial policy

1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
1

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 30382902316962), received between Apr 9, 2021 and Apr 9, 2021 — classified as 1 malfunction.

The most frequently reported specific device problem is “Incorrect, Inadequate or Imprecise Result or Readings” (1 report).

1 FDA recall record name this device's identifier, 1 still open.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Recalls naming this device

  1. Jan 8, 2024Class IIOpen, Classified

    There is a possibility of reproducibility, accuracy, and/or QC failures in antibiotic susceptibility testing (AST) for H. influenzae. This may cause product discard, delayed results, or additional adverse diagnostic outcomes, such as a delay in diagnosis, the selection of inappropriate antibiotics, or extended duration of antibiotic exposure and the treatment process.

    Z-1018-2024 · Root cause: Process control · Recall details · FDA record ↗

Most reported problems

Device problems

  • Incorrect, Inadequate or Imprecise Result or Readings1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionApr 9, 2021Incorrect, Inadequate or Imprecise Result or Readings; Incorrect, Inadequate or Imprecise Result or Readings

    IT WAS REPORTED THAT WHILE USING BD BBL¿ SENSI-DISC¿ CEFEPIME - 30 ¿G A FALSE SUSCEPTIBILITY RESULT WAS OBTAINED BY THE LABORATORY PERSONNEL. THE CUSTOMER STATED THERE WAS NO PATIENT IMPACT. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: CUSTOMER PROBLEM: CUSTOMER REPORTS 231696 LOT: 0042052 HAS DISCREPANT RESULTS STEPS TAKEN WITH CUSTOMER/TROUBLESHOOTING: OPENED A COMPLAINT. CUSTOMER IS PERFORMING A STUDY AND COMPARING BD SENSI DISCS TO VITEK 2 RESULTS. CUSTOMER REPORTS THAT THREE KLEBSIELLA PNEUMONIAE ESBL ISOLATES HAVE ZONES THAT INTERPRET AS RESISTANT BUT WHEN THE SAME ISOLATE IS RUN ON THE VITEK 2 THE RESULT IS SENSITIVE. FOLLOWED UP FOR ADDITIONAL DETAILS VIA PHONE BUT CUSTOMER HAS LEFT FOR THE DAY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11645008 ↗

Other SUSCEPTIBILITY TEST DISCS, ANTIMICROBIAL devices

All SUSCEPTIBILITY TEST DISCS, ANTIMICROBIAL devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page