Skip to content

WECK IPN028166Recalls & reported problems

Teleflex Incorporated · HORIZON TI MED 24 Clips/Pouch · Class 2 · Implant

All models of WECK (95)

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 44026704624797), received between Feb 23, 2023 and Feb 23, 2023 — classified as 1 injury.

The most frequently reported specific device problem is “Detachment of Device or Device Component” (1 report).

1 other recall cover devices cleared under the same FDA submission (K982313); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Detachment of Device or Device Component1

Patient problems

  • Hemorrhage/Blood Loss/Bleeding1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryFeb 23, 2023Detachment of Device or Device Component; Detachment of Device or Device Component

    REPORTED ISSUE: MULTIPLE CARDIAC POST-OP BLEEDS AS A RESULT OF LIGATING CLIPS COMING OFF ARTERIAL BRANCHES. THE PATIENT'S CONDITION IS UNKNOWN.

    Patient problems: Hemorrhage/Blood Loss/Bleeding

    MAUDE report 16428874 ↗

FDA clearance and classification

Cleared through 510(k) K982313 on Aug 10, 1998 (decision: Substantially Equivalent). Submitted by Weck Closure Systems as “Horizon Titanium Clips, Horizon Tantalum Clips”. The FDA review took 40 days. FDA record ↗

The FDA regulates product code FZP (clip, implantable) under 21 CFR 878.4300 as a Class II device. 21 CFR 878.4300 ↗

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Recalls under the same FDA submission

These recalls involve devices cleared under K982313. One submission often covers many models, so check the product and lot details in each record.

  • Z-2327-2016 · Aug 8, 2013 · Terminated
    Horizon 24 Large Titanium Clips with Adhesive Backing, Ref 004204, Rx Only, Sterile. The metal ligating clips are intended for use in procedures involving vessels or anatomic stru

Common questions about the WECK IPN028166

Has the WECK IPN028166 been recalled?

No FDA recall record in our data names this exact device identifier (DI 44026704624797), based on the FDA recall file dated Nov 27, 2026. However, 1 recall involves devices cleared under the same FDA submission. It may or may not include this model, so check the product, model and lot details in that record.

What problems have been reported with the WECK IPN028166?

The FDA's MAUDE database lists 1 adverse event report for this device, received on Feb 23, 2023. That report lists device problem “Detachment of Device or Device Component” (1); patient problem “Hemorrhage/Blood Loss/Bleeding” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the WECK IPN028166?

None of the reports are classified as deaths, 1 as an injury and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the WECK IPN028166 FDA approved?

It was cleared through 510(k) K982313 on Aug 10, 1998. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Is the WECK IPN028166 MRI safe?

According to the device's FDA GUDID record, its labeling lists it as MR Conditional: it can be scanned only under the specific conditions given in the labeling. The radiology team should check those conditions before an MRI.

Who makes the WECK IPN028166, and is it still sold?

The FDA's device database lists Teleflex Incorporated as the company responsible for it (brand WECK, model IPN028166). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other CLIP, IMPLANTABLE devices

All CLIP, IMPLANTABLE devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page