CLARITY IIRecalls & reported problems across all models
Lutronic Corporation · 3 models in the FDA device registry
Data updated Oct 16, 2026 from official FDA records · Editorial policy
1 open recall names at least one CLARITY II model. Check whether yours is affected in the recall details, and contact the manufacturer or your healthcare provider.
- Adverse event reports
- 41
- Deaths reported
- 0
- Injuries reported
- 11
- Recalls
- 1
We found 3 models of CLARITY II by Lutronic Corporation in the FDA's device registry (GUDID). Together they are named in 41 adverse event reports in the FDA's MAUDE database, received between Sep 23, 2022 and May 21, 2026 — classified as 11 injuries, 30 malfunctions.
The most frequently reported specific device problem is “Environmental Particulates” (14 reports).
1 FDA recall record name at least one of these models by its device identifier, 1 still open.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event. Widely used products collect more reports, so totals can't be used to compare products or estimate failure rates. Only reports that name a model's exact device identifier are counted. What reports can and can't tell you · How this data works
Reports received per month, all models
CLARITY II recalls
FDA recall records that name at least one of these models by its device identifier, newest first. Each recall usually covers specific models or lots, so check the details.
- Jan 27, 2026Open, Classified
Reports of devices sparking/popping and potentially burning patients.
Z-1558-2026 · Root cause: Device Design · Recall details · FDA record ↗
Most reported CLARITY II problems
Device problems
- Environmental Particulates14
- Insufficient Device Problem Information8
- Adverse Event Without Identified Device or Use Problem5
- Use of Incorrect Control/Treatment Settings4
- Operating System Version or Upgrade Problem3
- Defective Component2
- Electrical /Electronic Property Problem2
- Environmental Compatibility Problem2
Patient problems
- No Clinical Signs, Symptoms or Conditions15
- Burn(s)11
- Full thickness (Third Degree) Burn5
- Cryogenic Burn2
- Insufficient Information2
- Scar Tissue2
- Skin Inflammation/ Irritation2
- Blister1
CLARITY II models
3 models, most reported first. Each model has its own page with its reports, recalls and device details.
- CLARITY II CLARITY II ICDPowered Laser Surgical Instrument1 recall33 reports
- CLARITY II COMPL_BODY_ICDPowered Laser Surgical Instrument6 reports
- CLARITY II COMPL_BODY_AIRPowered Laser Surgical Instrument2 reports
Recent CLARITY II adverse event reports
The 15 most recent reports across all models, in the reporter's own words as published by the FDA.
MalfunctionMay 21, 2026Environmental Particulates
IT WAS REPORTED THAT SPARK AND SOOT OCCURRED DURING A LASER HAIR REMOVAL TREATMENT ON THE FACE USING CLARITY II. NO PATIENT INJURY WAS REPORTED. CYNOSURE LUTRONIC CLINICAL TEAM CONTACTED THE SITE TO INVESTIGATE THE EVENT. CYNOSURE LUTRONIC CLINICAL DETERMINED THE EVENT TO BE INCONCLUSIVE. SITE FAILED TO RESPOND TO MULTIPLE CONTACT ATTEMPTS AND THEREFORE ADDITIONAL DETAILS COULD NOT BE OBTAINED. A TRAINED CYNOSURE LUTRONIC FIELD SERVICE ENGINEER (FSE) WENT TO THE SITE TO PERFORM A DEVICE EVALUATION. CARTRIDGES 22, 18, AND 15 LENS WERE SPOTTED AND DAMAGED. WINDOW ON HANDPIECE WAS SPOTTED AND NEEDED REPLACEMENT. THE SMALL O-TYPE TIP THAT WAS USED FOR TREATMENT WAS DAMAGED WITH A SMALL BURN SPOT. TARGET OUTPUT WAS 45.62J BUT ACTUAL OUTPUT WAS 41.07J. FSE SUSPECT ENERGY LOSS FROM LENS DEGRADATION. ENERGY OUTPUTS FOR 1064NM AND 755NM WERE ALL WITHIN SPECIFICATION. FSE ORDERED REPLACEMENTS FOR DAMAGED LENS, HANDPIECE, AND O-TYPE TIP. SPARK THAT OCCURRED IS LIKELY RELATED TO THE CRYOGEN INVOLVED. CRYOGEN IS APPLIED TO THE TREATMENT SITE DURING VASCULAR TREATMENT TO PRECOOL THE SKIN. THE CRYOGEN BEGINS TO VAPORIZE FROM THE SURFACE OF THE SKIN SHORTLY AFTER CONTACT. THE LASER FIRES ONTO THE
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25242828 ↗MalfunctionMay 21, 2026Environmental Particulates
IT WAS REPORTED THAT SPARK AND SOOT OCCURRED DURING A LASER HAIR REMOVAL TREATMENT ON THE FACE USING CLARITY II. NO PATIENT INJURY WAS REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25242442 ↗MalfunctionApr 7, 2026Environmental Particulates
IT WAS REPORTED THAT BLACK SOOT WAS OBSERVED ON THE PATIENT'S NOSE DURING A VASCULAR TREATMENT USING CLARITY II. SITE CONFIRMED THAT NO PATIENT INJURIES OCCURRED. SITE HAD RELAYED THAT THEY USED NEWLY UPDATED ICD SETTINGS, BUT SOOT STILL OCCURRED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24800701 ↗MalfunctionApr 7, 2026Environmental Particulates
IT WAS REPORTED THAT BLACK SOOT WAS OBSERVED ON THE PATIENT'S NOSE DURING A VASCULAR TREATMENT USING CLARITY II. SITE CONFIRMED THAT NO PATIENT INJURIES OCCURRED. SITE HAD RELAYED THAT THEY USED NEWLY UPDATED ICD SETTINGS, BUT SOOT STILL OCCURRED. ON (B)(6) 2026 A MEMBER OF THE CYNOSURE LUTRONIC CLINICAL TEAM CONTACTED THE TREATMENT PROVIDER TO FURTHER INVESTIGATE THE EVENT. IT WAS SHARED THAT PATIENT'S LAST TWO TREATMENTS WERE PERFORMED WITH SAME SETTINGS AND WAS WELL TOLERATED. THE SETTINGS USED WERE 1064 NM, 5 MM HANDPIECE DIAMETER, 30 MS, 110 J/CM2, ICD 10/10/10, SINGLE PASS. DURING THE SAME SESSION, LASER HAIR REMOVAL WAS PERFORMED AFTERWARDS ON THE CLIENT'S EARS AND WAS WELL TOLERATED. THE DEVICE WAS THEN SWITCHED TO VASCULAR SETTINGS, INCORPORATING THE UPDATED ICD PARAMETERS. ONE PULSE WAS DELIVERED TO THE RIGHT SIDE OF THE NOSE WITHOUT ANY ISSUES. THE INCIDENT OCCURRED WHEN AN ADDITIONAL PULSE WAS APPLIED TO THE LEFT SIDE OF THE NOSE. THE TECHNICIAN NOTED A BRIGHT SPARK AT THE TIME OF TREATMENT, FOLLOWED BY THE APPEARANCE OF BLACK SOOT ON THE SKIN. ON (B)(6), 2026, SITE REPORTED THAT THE PATIENT IS PLEASED WITH THE VASCULAR IMPROVEMENT AND CONFIRMED THAT THERE WERE NO VISIB
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24800319 ↗InjuryMar 25, 2026Use of Device Problem
IT WAS REPORTED THAT A PATIENTS EXPERIENCED ELEVATED ERYTHEMA AND DARKENING WITH POSSIBLE BLISTERS ON THE ARMS FOLLOWING PIGMENTATION TREATMENT WITH A CLARITY II DEVICE. A MEMBER OF THE CYNOSURE LUTRONIC CLINICAL TEAM MADE CONTACT WITH THE TREATMENT SITE AND DETERMINED THAT THE TREATMENT PARAMETERS USED WERE SLIGHTLY AGGRESSIVE. THE CLARITY II QUICKSTART GUIDE (QSG) PARAMETERS FOR FLUENCE ARE 12-16. ADDITIONALLY, THE QSG STATES THAT ONE PASS IS RECOMMENDED DURING TREATMENT. THE PATIENT WAS TREATED AT 16J/CM2 WHICH IS WITHIN THE RECOMMENDED GUIDELINES OF THE QSG, HOWEVER, IT WAS NOTED THAT THE FLUENCE WAS AT THE MAXIMUM AND THAT THE PATIENT WAS TREATED WITH TWO (2) PASSES, WHICH MADE THE TREATMENT PARAMETERS USED AGGRESSIVE. THIS MAY HAVE CONTRIBUTED TO THE REPORTED SIDE EFFECTS. THE PATIENT WAS PRESCRIBED AQUAPHOR, TRIAMCINOLONE AND SILVADENE AS PREVENTATIVE AND WENT TO A PLASTIC SURGEON ON THEIR OWN FOR CONSULTATION. IMAGES OF THE PATIENTS BURN WERE SENT TO THE CYNOSURE LUTRONIC MEDICAL DIRECTOR WHO STATED THAT THERE WAS EITHER AREAS THAT HAVE LOSS OF EPIDERMIS OR LOSS OF DERMAL TISSUE AND THAT THERE WAS A POSSIBILITY OF SCARRING. IT WAS RECOMMENDED THAT THE PATIENT USES A GENTLE
Patient problems: Burn(s)
MAUDE report 24689988 ↗InjuryMar 25, 2026Use of Device Problem
IT WAS REPORTED THAT A PATIENTS EXPERIENCED ELEVATED ERYTHEMA AND DARKENING WITH POSSIBLE BLISTERS ON THE ARMS FOLLOWING PIGMENTATION TREATMENT WITH A CLARITY II DEVICE.
Patient problems: Burn(s)
MAUDE report 24688789 ↗MalfunctionMar 19, 2026Environmental Particulates
A TRAINED CYNOSURE LUTRONIC FIELD SERVICE ENGINEER (FSE) WENT TO THE TREATMENT PROVIDER SITE FOR A DEVICE EVALUATION. DURING THIS TIME THE DEVICE WAS SUBJECTED TO FULL FUNCTIONALITY TESTING AND VISUAL INSPECTION WITH PASSING RESULTS. THE DEVICE WAS FOUND TO BE WORKING TO PUBLISHED SPECIFICATIONS. A MEMBER OF THE CYNOSURE LUTRONIC CLINICAL TEAM MADE CONTACT WITH THE TREATMENT PROVIDER AND REVIEWED THE TREATMENT PARAMETERS USED. IT WAS REPORTED THAT THIS WAS THE PATIENTS SECOND TREATMENT AND THE CLINICAL TEAM DETERMINED THAT THE SETTINGS USED FOR THIS TREATMENT WERE WITHIN THE RECOMMENDED RANGE OF THE QUICKSTART GUIDE (QSG). THE ICD PARAMETERS USED WERE CONSISTENT WITH THE UPDATED GUIDELINES. THE TREATMENT PROVIDER CONFIRMED THAT THE LASER TIP WAS MAINTAINED PERPENDICULAR TO THE SKINS SURFACE AT ALL TIMES DURING TREATMENT WITHOUT PULSE OVERLAPPING. THE EXACT TREATMENT DATE OF THE FIRST TREATMENT IS UNKNOWN. THIS TREATMENT UTILIZED DIFFERENT ICD SETTINGS THAT WERE CONSISTENT WITH THE QSG GUIDELINES AT THAT TIME (10/20/10 MS) AND WAS REPORTED TO BE WELL TOLERATED, WITH NO SIDE EFFECTS REPORTED. THE CLINICAL TEAM REQUESTED UPDATES ON THE PATIENTS HEALING PROGRESS, UPDATED PHOTOS, AND AD
Patient problems: Burn(s)
MAUDE report 24643007 ↗MalfunctionMar 19, 2026Environmental Particulates
IT WAS REPORTED THAT A PATIENT EXPERIENCED A POTENTIAL LASER BURN AFTER A SPARK OCCURRED DURING LASER VASCULAR TREATMENT WITH A CLARITY II DEVICE. THE PATIENT EXPERIENCED BLISTERING AND THE SMALL O-RING TIP APPEARS TO BE BURNT.
Patient problems: Burn(s)
MAUDE report 24639285 ↗MalfunctionMar 13, 2026Insufficient Device Problem Information
IT WAS REPORTED THAT DURING TREATMENT SPARKS WERE COMING OUT OF THE TIP OF THE CLARITY II HANDPIECE (HP). THERE WAS NO PATIENT INJURY REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24594004 ↗MalfunctionMar 13, 2026Insufficient Device Problem Information
IT WAS REPORTED THAT DURING TREATMENT SPARKS WERE COMING OUT OF THE TIP OF THE CLARITY II HANDPIECE (HP). THERE WAS NO PATIENT INJURY REPORTED. A TRAINED CYNOSURE LUTRONIC FIELD SERVICE ENGINEER WENT TO THE TREATMENT PROVIDER SITE FOR A DEVICE EVALUATION. DURING THIS TIME, THE FSE DID NOT OBSERVE THE DEVICE SPARKING, HOWEVER, TESTING FOUND THE DEVICE WAS NOT WORKING TO THE PUBLISHED SPECIFICATIONS. THE SPOT SIZES 18 AND 25 WERE VISUALLY INSPECTED AND OBSERVED SOME DAMAGE. IT IS UNDETERMINED WHAT CAUSED THIS DAMAGE, OR IF IT CONTRIBUTED TO THE REPORTED SPARKING BUT TO CORRECT THE OBSERVATION, REPLACEMENT SPOT SIZES WERE ORDERED. A MEMBER OF THE CYNOSURE LUTRONIC CLINICAL TEAM MADE CONTACT WITH THE TREATMENT PROVIDER AND CONFIRMED THAT THERE WAS NO PATIENT INJURIES. THE TREATMENT PROVIDER REPORTED THAT THEY REPLACED THE HP WINDOW AND THE SPARKING DID NOT OCCUR AGAIN. THE TREATMENT PROVIDER REPORTED THAT THE WINDOW WAS DAMAGED, HOWEVER, THERE WAS NO IMAGE OF THE WINDOW NOR WAS IT WAS RETURNED FOR FURTHER EVALUATION. THEREFORE, IT IS UNDETERMINED IF ANY DAMAGE OR POSSIBLE PARTICULATE ON THE WINDOW CONTRIBUTED TO THE REPORTED SPARKING. TO REDUCE THE PROBABILITY OF REOCCURRENCE, THE CLEA
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24590312 ↗MalfunctionMar 11, 2026Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT DURING LASER VASCULAR TREATMENT WITH A CLARITY II DEVICE, A SPARK OCCURRED FOLLOWED BY VISIBLE BLACK "SOOT" ON THE SKIN. A TRAINED CYNOSURE LUTRONIC FIELD SERVICE ENGINEER (FSE) WENT TO THE TREATMENT PROVIDER SITE FOR A DEVICE EVALUATION. DURING THIS TIME, THERE WAS NO EVIDENCE OF OBSERVATION OF THE DEVICE SPARKING MADE BY THE FSE. THE DEVICE WAS VISUALLY INSPECTED FOR DAMAGE, AND IT WAS OBSERVED TO HAVE DEBRIS IN THE AIR FILTER AND THE HANDPIECE (HP) FILTER, THIS WAS CLEANED TO CORRECT THE OBSERVATION. IT IS UNKNOWN IF THIS CONTRIBUTED TO THE REPORTED ISSUE. THE CUSTOMER WAS SHOWN HOW TO INSPECT AND CLEAN THE HP FILTER. IT WAS OBSERVED A GROUNDING COIL WAS NOT INSTALLED AND THE FSE INSTALLED ONE, IT IS UNDETERMINED IF THIS CONTRIBUTED TO THE REPORTED ISSUE. THE DEVICE WAS SUBJECTED TO FULL FUNCTIONALITY TESTING WITH PASSING RESULTS. THERE WAS NO INDICATION OF A DEVICE MALFUNCTION. A MEMBER OF THE CYNOSURE LUTRONIC CLINICAL TEAM MADE CONTACT WITH THE TREATMENT PROVIDER AND FOUND THAT THE TREATMENT WAS PERFORMED ON (B)(6) 2026 FOR TELANGIECTASIA ON THE NOSE. DURING THE PROCEDURE, A LOUD POP WAS HEARD AND OBSERVED WITH A BRIGHT SPARK, THIS WAS FOLLOWED BY WHAT AP
Patient problems: Insufficient Information
MAUDE report 24575684 ↗MalfunctionMar 11, 2026Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT DURING LASER VASCULAR TREATMENT WITH A CLARITY II DEVICE, A SPARK OCCURRED FOLLOWED BY VISIBLE BLACK "SOOT" ON THE SKIN.
Patient problems: Insufficient Information
MAUDE report 24567944 ↗InjuryMar 4, 2026Environmental Particulates
IT WAS REPORTED THAT DURING VESSEL TREATMENT ON THE NOSE AND CHEEKS, A LOUD "POP" SOUND WAS HEARD FOLLOWED BY A SPARK AND A BLACK SOOT MARK WAS LEFT ON THE PATIENT. THE SOOT WAS WIPED AWAY AND WHEN THE PATIENT RETURNED FOR FOLLOW-UP TREATMENT APPROXIMATELY A MONTH LATER, THERE WAS A RED CIRCLE ON THE NOSE THAT STARTED TO SCAB.
Patient problems: Skin Inflammation/ Irritation
MAUDE report 24512809 ↗InjuryMar 4, 2026Off-Label Use
IT WAS REPORTED THAT A PATIENT EXPERIENCED A POTENTIAL LASER BURN ON THE FACE FOLLOWING LASER VASCULAR TREATMENT ON THE FACE WITH A CLARITY II DEVICE. A TRAINED CYNOSURE LUTRONIC FIELD SERVICE ENGINEER WENT TO THE TREATMENT PROVIDER SITE FOR A DEVICE EVALUATION. DURING THIS TIME, THE DEVICE WAS SUBJECTED TO MULTIPLE TESTS INCLUDING FULL FUNCTIONALITY TESTING WITH PASSING RESULTS. THE DEVICE WAS FOUND TO BE WORKING TO PUBLISHED SPECIFICATIONS. A MEMBER OF THE CYNOSURE LUTRONIC CLINICAL TEAM MADE CONTACT WITH THE TREATMENT PROVIDER AND DETERMINED THAT THE PATIENT WAS TREATED WITH AN OFF LABEL TREATMENT. VASCULAR LASER TREATMENTS ARE NOT CONSIDERED OFF LABEL IN CANADA WITH THE EXCEPTION OF PORT WINE STAIN INDICATIONS. TREATMENT PARAMETER DETAILS WERE REQUESTED, BUT THE TREATMENT PROVIDER DID NOT SUPPLY COMPLETE CLINICAL DETAILS INCLUDING TREATMENT PARAMETERS, PROTOCOL LAYERING, TECHNIQUE DETAILS, DEGREE OF OVERLAP AND USE OF ADDITIONAL POST COOLING REMAINS UNKNOWN. THE PATIENT UNDERWENT TWO TREATMENTS FOR TELANGIECTASIA AND ROSACEA ON BOTH CHEEKS. THE FIRST TREATMENT WAS ON (B)(6) 2025 AND WAS WELL TOLERATED WITH NO REPORTED SIDE EFFECTS. TREATMENT NUMBER TWO (#2) WAS PERFORMED ON (B)
Patient problems: Scar Tissue
MAUDE report 24512087 ↗MalfunctionMar 4, 2026Environmental Particulates
IT WAS REPORTED THAT DURING VESSEL TREATMENT ON THE NOSE AND CHEEKS, A LOUD "POP" SOUND WAS HEARD FOLLOWED BY A SPARK AND A BLACK SOOT MARK WAS LEFT ON THE PATIENT. THE SOOT WAS WIPED AWAY AND WHEN THE PATIENT RETURNED FOR FOLLOW-UP TREATMENT APPROXIMATELY A MONTH LATER, THERE WAS A RED CIRCLE ON THE NOSE THAT STARTED TO SCAB. A TRAINED CYNOSURE LUTRONIC FIELD SERVICE ENGINEER WENT TO THE TREATMENT PROVIDER SITE FOR A DEVICE EVALUATION. DURING THIS TIME, THE REPORTED ISSUE WAS UNABLE TO BE DUPLICATED. THE DEVICE WAS SUBJECTED TO MULTIPLE TESTS INCLUDING FULL FUNCTIONALITY TESTING, ENERGY TESTS AND FULL VISUAL INSPECTION WITH NO DISCREPANCIES OBSERVED. THE DEVICE WAS FOUND TO BE WORKING WITHIN PUBLISHED SPECIFICATIONS. IT IS UNDETERMINED WHAT CAUSED THE REPORTED INCIDENT. A MEMBER OF THE CYNOSURE LUTRONIC CLINICAL TEAM MADE CONTACT WITH THE TREATMENT PROVIDER AND DETERMINED THAT THE PROVIDER TREATED THE PATIENT WITH AN OFF LABEL INDICATION AT THEIR OWN DISCRETION. IT IS UNKNOWN IF THIS CONTRIBUTED TO THE REPORTED LOUD POP, SPARK AND BLACK MARK THAT WAS REPORTED TO BE LEFT ON THE PATIENT, OR THE RED MARK THAT REMAINED ON THE PATIENTS NOSE ONE MONTH POST TREATMENT. TO REDUCE THE PROBA
Patient problems: Skin Inflammation/ Irritation
MAUDE report 24507900 ↗
Other Lutronic Corporation products
All Lutronic Corporation devices →Sources and updates
- Models: FDA GUDID, file dated Oct 13, 2026. Models are grouped by the brand name the manufacturer registered.
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page