EVIS EXERA III DUODENOVIDEOSCOPE OLYMPUS TJF-Q190VRecalls & reported problems across all models

Olympus Medical Systems Corp. · 2 models in the FDA device registry

Data updated Oct 18, 2026 from official FDA records · Editorial policy

4 open recalls name at least one EVIS EXERA III DUODENOVIDEOSCOPE OLYMPUS TJF-Q190V model. Check whether yours is affected in the recall details, and contact the manufacturer or your healthcare provider.

Adverse event reports
5,281
Deaths reported
10
Injuries reported
550
Recalls
4

We found 2 models of EVIS EXERA III DUODENOVIDEOSCOPE OLYMPUS TJF-Q190V by Olympus Medical Systems Corp. in the FDA's device registry (GUDID). Together they are named in 5,281 adverse event reports in the FDA's MAUDE database, received between Jan 6, 2021 and Sep 30, 2026 — classified as 10 deaths, 550 injuries, 4,721 malfunctions.

The most frequently reported specific device problem is “Failure to Clean Adequately” (1,055 reports).

4 FDA recall records name at least one of these models by its device identifier, 4 still open.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event. Widely used products collect more reports, so totals can't be used to compare products or estimate failure rates. Only reports that name a model's exact device identifier are counted. What reports can and can't tell you · How this data works

Reports received per month, all models

Nov 2023: 111 reportsDec 2023: 97 reportsJan 2024: 232 reportsFeb 2024: 92 reportsMar 2024: 110 reportsApr 2024: 87 reportsMay 2024: 77 reportsJun 2024: 67 reportsJul 2024: 49 reportsAug 2024: 71 reportsSep 2024: 89 reportsOct 2024: 106 reportsNov 2024: 40 reportsDec 2024: 6 reportsJan 2025: 23 reportsFeb 2025: 12 reportsMar 2025: 22 reportsApr 2025: 17 reportsMay 2025: 11 reportsJun 2025: 24 reportsJul 2025: 20 reportsAug 2025: 27 reportsSep 2025: 57 reportsOct 2025: 90 reportsNov 2025: 117 reportsDec 2025: 252 reportsJan 2026: 291 reportsFeb 2026: 137 reportsMar 2026: 100 reportsApr 2026: 238 reportsMay 2026: 402 reportsJun 2026: 283 reportsJul 2026: 259 reportsAug 2026: 272 reportsSep 2026: 282 reportsOct 2026: 0 reports202420252026402
Last 36 months. The most recent month may be incomplete.

EVIS EXERA III DUODENOVIDEOSCOPE OLYMPUS TJF-Q190V recalls

FDA recall records that name at least one of these models by its device identifier, newest first. Each recall usually covers specific models or lots, so check the details.

  1. Oct 14, 2025Class IIOpen, Classified

    Continued reports of positive cultures and infections have identified updates to the reprocessing materials to minimize potential deviations in TJF duodenoscope reprocessing. Olympus is informing users of these changes, reminding users to closely follow the operation and reprocessing instructions, and providing updated materials to users.

    Z-0579-2026 · Root cause: Device Design · names 2 of these models · Recall details · FDA record ↗

  2. May 5, 2025Class IIOpen, Classified

    Recent post-market surveillance data suggests a possible association of higher microbial contamination levels from TJF duodenoscopes when manual cleaning was delayed beyond one hour and a presoak was performed, compared to those TJF duodenoscopes where manual cleaning began within one hour after patient procedure.

    Z-1911-2025 · Root cause: Labeling design · Recall details · FDA record ↗

  3. Sep 25, 2023Class IIOpen, Classified

    Channel air drying process was not validated, and that a small percentage of scopes returned to customers after repair had a wet channel. Water remaining in the channel of the endoscopes has the potential for contamination that could lead to the risk of infection

    Z-0346-2024 · Root cause: Under Investigation by firm · Recall details · FDA record ↗

  4. Jul 27, 2023Class IIOpen, Classified

    Recent reports of patient infection.

    Z-2467-2023 · Root cause: Under Investigation by firm · Recall details · FDA record ↗

Most reported EVIS EXERA III DUODENOVIDEOSCOPE OLYMPUS TJF-Q190V problems

Device problems

  • Failure to Clean Adequately1,055
  • Crack871
  • Detachment of Device or Device Component783
  • Peeled/Delaminated764
  • Microbial Contamination of Device397
  • Material Fragmentation309
  • Degraded265
  • Device Reprocessing Problem213

Patient problems

  • No Clinical Signs, Symptoms or Conditions4,965
  • Foreign Body In Patient97
  • Unspecified Tissue Injury89
  • Hemorrhage/Blood Loss/Bleeding28
  • Laceration(s)23
  • Unspecified Infection18
  • Bacterial Infection15
  • Insufficient Information12

EVIS EXERA III DUODENOVIDEOSCOPE OLYMPUS TJF-Q190V models

2 models, most reported first. Each model has its own page with its reports, recalls and device details.

Recent EVIS EXERA III DUODENOVIDEOSCOPE OLYMPUS TJF-Q190V adverse event reports

The 15 most recent reports across all models, in the reporter's own words as published by the FDA.

Other Olympus Medical Systems Corp. products

All Olympus Medical Systems Corp. devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page