G7 OSSEOTI ACETABULAR SHELLRecalls & reported problems across all models
Biomet Orthopedics, LLC · 18 models in the FDA device registry
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 62
- Deaths reported
- 0
- Injuries reported
- 40
- Recalls
- 0
We found 18 models of G7 OSSEOTI ACETABULAR SHELL by Biomet Orthopedics, LLC in the FDA's device registry (GUDID). Together they are named in 62 adverse event reports in the FDA's MAUDE database, received between Jul 27, 2017 and Sep 14, 2026 — classified as 40 injuries, 22 malfunctions.
The most frequently reported specific device problem is “Loosening of Implant Not Related to Bone-Ingrowth” (11 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event. Widely used products collect more reports, so totals can't be used to compare products or estimate failure rates. Only reports that name a model's exact device identifier are counted. What reports can and can't tell you · How this data works
Reports received per month, all models
Most reported G7 OSSEOTI ACETABULAR SHELL problems
Device problems
- Adverse Event Without Identified Device or Use Problem17
- Loosening of Implant Not Related to Bone-Ingrowth11
- Difficult to Insert6
- Migration4
- Positioning Failure4
- Detachment of Device or Device Component3
- Fracture3
- Device Dislodged or Dislocated2
Patient problems
- No Clinical Signs, Symptoms or Conditions21
- Pain12
- Failure of Implant7
- Insufficient Information7
- Unspecified Infection6
- Aseptic loosening3
- Bone Fracture(s)3
- Joint Dislocation3
G7 OSSEOTI ACETABULAR SHELL models
18 models, most reported first. Each model has its own page with its reports, recalls and device details.
- G7 OSSEOTI ACETABULAR SHELL 110010243Hip, semi-constrained, cemented, metal/polymer + additive, cemented10 reports
- G7 OSSEOTI ACETABULAR SHELL 110010244Hip, semi-constrained, cemented, metal/ceramic/polymer + additive, porous uncemented7 reports
- G7 OSSEOTI ACETABULAR SHELL 110010265prosthesis, hip, constrained, cemented or uncemented, metal/polymer, + additive7 reports
- G7 OSSEOTI ACETABULAR SHELL 110010245Prosthesis, hip, constrained, cemented or uncemented, metal/polymer5 reports
- G7 OSSEOTI ACETABULAR SHELL 110010266prosthesis, hip, constrained, cemented or uncemented, metal/polymer, + additive5 reports
- G7 OSSEOTI ACETABULAR SHELL 110010269prosthesis, hip, constrained, cemented or uncemented, metal/polymer, + additive5 reports
- G7 OSSEOTI ACETABULAR SHELL 110010242Hip, semi-constrained, cemented, metal/polymer + additive, cemented4 reports
- G7 OSSEOTI ACETABULAR SHELL 110010247Hip, semi-constrained, cemented, metal/polymer + additive, cemented4 reports
- G7 OSSEOTI ACETABULAR SHELL 110010263prosthesis, hip, constrained, cemented or uncemented, metal/polymer, + additive4 reports
- G7 OSSEOTI ACETABULAR SHELL 110010264Hip, semi-constrained, cemented, metal/ceramic/polymer + additive, porous uncemented2 reports
- G7 OSSEOTI ACETABULAR SHELL 110010268Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented2 reports
- G7 OSSEOTI ACETABULAR SHELL 110010241Hip, semi-constrained, cemented, metal/ceramic/polymer + additive, porous uncemented1 report
- G7 OSSEOTI ACETABULAR SHELL 110010246Prosthesis, hip, semi-constrained, metal/polymer, cemented1 report
- G7 OSSEOTI ACETABULAR SHELL 110010248Prosthesis, hip, constrained, cemented or uncemented, metal/polymer1 report
- G7 OSSEOTI ACETABULAR SHELL 110010249prosthesis, hip, constrained, cemented or uncemented, metal/polymer, + additive1 report
- G7 OSSEOTI ACETABULAR SHELL 110010267Hip, semi-constrained, cemented, metal/polymer + additive, cemented1 report
- G7 OSSEOTI ACETABULAR SHELL 110010271prosthesis, hip, constrained, cemented or uncemented, metal/polymer, + additive1 report
- G7 OSSEOTI ACETABULAR SHELL 110010273Prosthesis, hip, constrained, cemented or uncemented, metal/polymer1 report
Recent G7 OSSEOTI ACETABULAR SHELL adverse event reports
The 15 most recent reports across all models, in the reporter's own words as published by the FDA.
InjurySep 14, 2026Adverse Event Without Identified Device or Use Problem
It was reported that, following a right total hip arthroplasty, radiographs demonstrated heterotopic ossification of the right acetabulum, and the patient reported moderate pain and stiffness managed with daily NSAIDs and CBD. Attempts have been made and no further information has been provided.
Patient problems: Extraskeletal ossification; Pain
MAUDE report 50751866 ↗InjuryApr 13, 2026Device Dislodged or Dislocated
IT WAS REPORTED THAT THE PATIENT UNDERWENT A REVISION APPROXIMATELY TWO (2) WEEKS AFTER INITIAL SURGERY DUE TO THE METAL LINER NOT PROPERLY SEATED AND DISLOCATED FROM THE CUP AFTER THE SURGERY. THE LINER AND BEARING WERE REMOVED AND REPLACED. ATTEMPTS HAVE BEEN MADE AND ADDITIONAL INFORMATION ON THE REPORTED EVENT IS UNAVAILABLE AT THIS TIME.
Patient problems: Joint Dislocation
MAUDE report 24866346 ↗InjuryDec 3, 2025Loosening of Implant Not Related to Bone-Ingrowth; Loosening of Implant Not Related to Bone-Ingrowth
IT WAS REPORTED THAT THE PATIENT UNDERWENT INITIAL LEFT TOTAL HIP ARTHROPLASTY. SUBSEQUENTLY, PATIENT UNDERWENT A THIRD LEFT HIP REVISION DUE TO ASEPTIC LOOSENING APPROXIMATELY 8 (EIGHT) MONTHS LATER. DURING THE REVISION, THE CUP WAS FOUND TO BE GROSSLY LOOSE AND REMOVED WITHOUT DIFFICULTY, FEMORAL STEM WAS ALSO NOTED TO BE LOOSE. ALL IMPLANTS WERE REVISED WITHOUT COMPLICATIONS. ATTEMPTS HAVE BEEN MADE AND ADDITIONAL INFORMATION ON THE REPORTED EVENT IS UNAVAILABLE AT THIS TIME.
Patient problems: Ambulation or Postural Difficulties; Aseptic loosening; Pain; Radiolucent Lines
MAUDE report 23711960 ↗InjuryAug 26, 2025Unintended Movement; Noise, Audible; Unintended Movement; Noise, Audible
IT WAS REPORTED THAT THE PATIENT EXPERIENCED SNAPPING IN THE HIP APPROXIMATELY TWO YEARS POST-IMPLANTATION. IT WAS CONFIRMED THAT THE PATIENT HAD ILIOPSOAS TENDINITIS CAUSED BY IMPINGEMENT. PATIENT WAS REFERRED FOR AN INJECTION UNDER FLUOROSCOPY. FOLLOW- UPS TO GATHER ADDITIONAL INFORMATION ARE CURRENTLY IN PROCESS.
Patient problems: Joint Impingement; Pain; Tendinopathy
MAUDE report 22893032 ↗InjuryJul 28, 2025Detachment of Device or Device Component; Detachment of Device or Device Component
IT WAS REPORTED THAT THE PATIENT UNDERWENT AN INITIAL HIP PROCEDURE. SUBSEQUENTLY, THE PATIENT WAS REVISED APPROXIMATELY 8 YEARS LATER DUE TO THE LINER DISASSEMBLING. ATTEMPTS HAVE BEEN MADE, AND NO FURTHER INFORMATION HAS BEEN PROVIDED.
Patient problems: Insufficient Information
MAUDE report 22629663 ↗InjuryJul 22, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED PATIENT UNDERWENT A REVISION PROCEDURE APPROXIMATELY ONE WEEK POST IMPLANTATION DUE TO PAIN. RADIOGRAPHIC IMAGING DISPLAYED A BONY ACETABULAR FRACTURE. ATTEMPTS HAVE BEEN MADE, AND NO FURTHER INFORMATION HAS BEEN PROVIDED.
Patient problems: Pain; Periprosthetic fracture
MAUDE report 22563641 ↗InjuryJul 7, 2025Loosening of Implant Not Related to Bone-Ingrowth; Loosening of Implant Not Related to Bone-Ingrowth
IT WAS REPORTED THAT THE PATIENT UNDERWENT AN INITIAL HIP PROCEDURE. SUBSEQUENTLY, THE PATIENT WAS REVISED APPROXIMATELY 2 YEARS LATER DUE TO ACETABULAR LOOSENING. IT WAS REPORTED THAT NO FURTHER INFORMATION IS AVAILABLE.
Patient problems: Aseptic loosening
MAUDE report 22411183 ↗InjuryJun 18, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT A PATIENT HAD AN INITIAL LEFT TOTAL HIP ARTHROPLASTY. AT 2 YEARS POSTOP, THE PATIENT REPORTS ONGOING MODERATE LOW BACK PAIN THAT WAS NOT PRESENT PRIOR TO THE INITIAL PROCEDURE. IT WAS INITIALLY THOUGHT TO BE GENERAL POSTOP SORENESS, BUT THE PAIN HAS NOT RESOLVED AND CONTINUES TO LIMIT DAILY ACTIVITIES. THE PATIENT HAS STARTED THERAPY FOR THE LOW BACK PAIN, TAKES NSAIDS FOR PAIN, AND USES A CANE FOR LONG DISTANCES. ATTEMPTS HAVE BEEN MADE AND NO FURTHER INFORMATION HAS BEEN PROVIDED.
Patient problems: Pain
MAUDE report 22284953 ↗MalfunctionMay 29, 2025Positioning Failure; Device-Device Incompatibility; Positioning Failure; Device-Device Incompatibility
IT WAS REPORTED THAT DURING THE PROCEDURE, THE CUP WAS IMPLANTED WITH THREE SCREWS. A LINER WAS ATTEMPTED TO BE IMPLANTED AND WOULD NOT MATE WITH THE CUP. A SECOND LINER WAS OPENED AND ALSO WOULD NOT MATE WITH THE CUP. TRYING TO PLACE THE LINER RESULTED IN THE CUP LOSING FIXATION. THE SHELL AND SCREWS WERE REMOVED AND A SECOND, LARGER CUP WAS IMPLANTED. THE LINER WOULD STILL NOT MATE WITH THE CUP. A THIRD LINER WAS ABLE TO BE IMPLANTED INTO THE SECOND CUP. THERE WAS NO KNOWN IMPACT OR CONSEQUENCES TO THE PATIENT. ATTEMPTS HAVE BEEN MADE AND NO FURTHER INFORMATION HAS BEEN PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22109043 ↗MalfunctionMay 9, 2025Positioning Failure; Positioning Failure
IT WAS REPORTED THAT THE TRILOGY SCREW WENT THROUGH THE G7 50MM CUP. NO KNOWN IMPACT OR CONSEQUENCE TO THE PATIENT. IT WAS REPORTED THAT NO FURTHER INFORMATION IS AVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21992611 ↗InjuryApr 3, 2025Loosening of Implant Not Related to Bone-Ingrowth; Migration; Loosening of Implant Not Related to Bone-Ingrowth; Migration
IT WAS REPORTED THAT APPROXIMATELY EIGHT YEARS POST-IMPLANTATION, THE PATIENT UNDERWENT A HIP REVISION DUE TO PAIN AND LOOSENING OF THE CUP FROM ACETABULAR BONE. ATTEMPTS HAVE BEEN MADE AND NO FURTHER INFORMATION HAS BEEN PROVIDED.
Patient problems: Aseptic loosening; Failure of Implant; Pain
MAUDE report 21761221 ↗InjuryJan 14, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
ADDITIONAL INFORMATION RECEIVED. IT WAS REPORTED THAT THE PATIENT¿S OSSIFICATION SITE WAS SEEN ON PRE-OPERATIVE IMAGES AND THE PATIENT HAS BEEN THROUGH THE COURSE OF RADIOGRAPHIC IMAGING, INCLUDING A RECENT CT SCAN COMPLETED APPROXIMATELY TWO MONTHS AGO. IT WAS REPORTED THAT THERE WAS NO TRAUMA OR OTHER SPECIFIC CONTRIBUTING FACTORS WHICH COULD EXPLAIN THE SYMPTOMS. PATIENT WAS DESCRIBED AS A HEALTHY, FULLY COMPLIANT PERSON WITH GOOD MOTIVATION AND FOCUS ON POSTOP REHABILITATION. THE PATIENT HAS A NORMAL ACTIVITY LEVEL AND REGULAR CONTACT WITH PHYSIO. THE PATIENT IS NOW SCHEDULED TO HAVE AN ULTRASOUND GUIDED INJECTION AT THE OSSIFICATION SITE FOR DIAGNOSTIC PURPOSES. IT WAS REPORTED THAT NO FURTHER INFORMATION IS AVAILABLE.
Patient problems: Extraskeletal ossification; Pain
MAUDE report 21154859 ↗InjuryDec 6, 2024Loosening of Implant Not Related to Bone-Ingrowth; Loosening of Implant Not Related to Bone-Ingrowth
IT WAS REPORTED THAT THE PATIENT UNDERWENT AN INITIAL HIP PROCEDURE. SUBSEQUENTLY, THE PATIENT WAS REVISED APPROXIMATELY 19 MONTHS LATER DUE TO ACETABULAR LOOSENING. IT WAS REPORTED THAT NO FURTHER INFORMATION HAS BEEN PROVIDED.
Patient problems: Insufficient Information
MAUDE report 20864249 ↗MalfunctionOct 23, 2024Difficult to Insert; Difficult to Insert
IT WAS REPORTED THAT DURING THE SURGERY THE SURGEON TRIED TO INSERT THE LINER INTO THE SHELL, HOWEVER IT WOULD NOT MATE. THE SURGEON MADE SURE THERE WAS NO SCREWS OR SOFT TISSUE KEEPING THE LINER FROM INSERTING. THE CUP AND LINER WERE NOT USED. THERE WAS NO KNOWN IMPACT OR CONSEQUENCES TO THE PATIENT. ATTEMPTS HAVE BEEN MADE AND NO FURTHER INFORMATION HAS BEEN PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20516681 ↗MalfunctionOct 7, 2024Packaging Problem; Packaging Problem
IT WAS REPORTED THAT DURING A REVISION OF ZIMMER BIOMET PRODUCTS, THE INNER PACKAGING HAD MELTED, MAKING IT IMPOSSIBLE TO UNPACK THE PRODUCT. NO KNOWN IMPACT OR CONSEQUENCES TO THE PATIENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20383072 ↗
Other Biomet Orthopedics, LLC products
- AFFIXUSHIP FRACTURE NAIL - RIGHT39 models · 6 reports · 37 recalls
- AFFIXUSHIP FRACTURE NAIL - LEFT27 models · 7 reports · 24 recalls
- Compress Device71 models · 99 reports · 22 recalls
- Arcos Modular Revision Hip System71 models · 191 reports · 19 recalls
- Comprehensive Reverse Shoulder57 models · 895 reports · 3 recalls
- Vanguard Knee System147 models · 306 reports · 13 recalls
- STAGEONE17 models · 0 reports · 18 recalls
- StageOne Select15 models · 2 reports · 15 recalls
Sources and updates
- Models: FDA GUDID, file dated Oct 13, 2026. Models are grouped by the brand name the manufacturer registered.
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.