HFD100Recalls & reported problems across all models
IMRIS Imaging, Inc. · 3 models in the FDA device registry
Data updated Oct 16, 2026 from official FDA records · Editorial policy
1 open recall names at least one HFD100 model. Check whether yours is affected in the recall details, and contact the manufacturer or your healthcare provider.
- Adverse event reports
- 7
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls
- 2
We found 3 models of HFD100 by IMRIS Imaging, Inc. in the FDA's device registry (GUDID). Together they are named in 7 adverse event reports in the FDA's MAUDE database, received between Nov 1, 2021 and Dec 4, 2025 — classified as 7 malfunctions.
The most frequently reported specific device problem is “Unintended Movement” (3 reports).
2 FDA recall records name at least one of these models by its device identifier, 1 still open.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event. Widely used products collect more reports, so totals can't be used to compare products or estimate failure rates. Only reports that name a model's exact device identifier are counted. What reports can and can't tell you · How this data works
Reports received per month, all models
HFD100 recalls
FDA recall records that name at least one of these models by its device identifier, newest first. Each recall usually covers specific models or lots, so check the details.
- Dec 8, 2025Open, Classified
Torque screw may crack or separate. If used, an affected screw could lead to inadequate head stabilization, compromised surgical precision, procedural delays, requirement for alternate head fixation methods, and risk of patient injury.
Z-1034-2026 · Root cause: Device Design · Recall details · FDA record ↗
- Feb 17, 2022Terminated
Reports have been received that after normal or routine lateral forces are applied to the head fixation device, the split block clamp may deflect (rotationally around the axis) and not return to within acceptable distance from its prior position after the force is removed. In order to reduce deflection at the table mount location, users have tightened the hand knob screw to a degree that it is then difficult to untighten it later in the clinical workflow. Rotational movement at the table attachment point could result in HFD movement going unnoticed, which could result in a situation where surgical or medical intervention is necessary, a situation where navigation needs to be reestablished, or a situation resulting in extended time under anesthesia for the patient. It may also be difficult to loosen the mount clamp component after use, potentially leading to ergonomic injury or a workaround during equipment teardown.
Z-0934-2022 · Root cause: Device Design · names 2 of these models · Recall details · FDA record ↗
Most reported HFD100 problems
Device problems
- Unintended Movement3
- Break2
- Patient-Device Incompatibility1
- Unstable1
Patient problems
- No Clinical Signs, Symptoms or Conditions6
- Skull Fracture1
HFD100 models
3 models, most reported first. Each model has its own page with its reports, recalls and device details.
- HFD100 119629-000Holder, Head, Neurosurgical (Skull Clamp)1 recall6 reports
- HFD100 119695-000Holder, Head, Neurosurgical (Skull Clamp)1 recall1 report
- HFD100 119630-000Holder, Head, Neurosurgical (Skull Clamp)1 recall0 reports
Recent HFD100 adverse event reports
The 7 most recent reports across all models, in the reporter's own words as published by the FDA.
MalfunctionDec 4, 2025Patient-Device Incompatibility; Patient-Device Incompatibility
IT WAS REPORTED A MINOR INJURY OCCURRED WHILE PINNING A SIX (6) YEAR OLD PATIENT USING THE HFD100 DEVICE DURING A CRANIOTOMY. DETAILS OF EVENT WERE PROVIDED BY A NURSE VIA EMAIL ON NOVEMBER 6, 2025. THE NURSE OBSERVED THE SKULL CLAMP WAS TIGHTENED BY THE SURGEON WHO IMMEDIATELY NOTICED A LOSS OF PRESSURE. THE SURGEON THEORIZED THE CLAMP (PART OF THE HFD100) MAY BE BROKEN OR THE PATIENT HAS A FRACTURE DUE TO A THIN SKULL. A CT OF THE PATIENT'S HEAD WAS CONDUCTED WHILE UNDER ANESTHESIA, WHICH ADDED AN ADDITIONAL 30 MINUTES TO THE OVERALL OR TIME, AND SMALL BILATERAL SKULL FACTURES WERE SEEN. IT WAS REPORTED THE SKULL FRACTURES DID NOT REQUIRE INTERVENTION. THE NEUROSURGEON USED THE HORSESHOE HEADREST IN THE SUPINE POSITION TO COMPLETE THE CRANIOTOMY, AND THE PROCEDURE WAS COMPLETED SUCCESSFULLY. IMRIS FOLLOWED UP WITH THE CUSTOMER, WHO INDICATED THE PRESSURE APPLIED TO SKULL WAS 45 POUNDS. IT WAS FURTHER CONFIRMED THE PATIENT HAD FRACTURES ON BOTH SIDES OF THE SKULL.
Patient problems: Skull Fracture
MAUDE report 23723010 ↗MalfunctionOct 9, 2024Break; Break
A CUSTOMER REPORTED THAT THE TORQUE SCREW OF AN HFD100 HEAD FIXATION DEVICE BROKE AS THE TORQUE SCREW WAS BEING ADVANCED THROUGH THE THREADS OF THE HFD100. THE BREAK WAS REPORTED TO OCCUR IMMEDIATELY UPON INSERTING THE TORQUE SCREW WITH LITTLE PRESSURE BEING APPLIED. THE PROCEDURE WAS COMPLETED BY USING A SECOND AVAILABLE TORQUE SCREW. NO DELAY OR IMPACT TO THE PATIENT OR PROCEDURE WAS REPORTED; THE PATIENT WAS REPORTED TO BE STABLE AND THE PROCEDURE WAS REPORTED TO BE SUCCESSFUL.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20413016 ↗MalfunctionApr 5, 2023Unstable; Unstable
THE CUSTOMER REPORTED THE HEAD HOLDER FOR OPERATIONS ASSEMBLY IS TOO LOOSE, AND THAT DURING SET UP OF THE EQUIPMENT FOR THE HFD100 HEAD FIXATION DEVICE, THE LINKAGE WAS LOOSE/WOBBLY AND WAS REPLACED PRIOR TO A LITT PROCEDURE. THE CUSTOMER REPORTED THE PATIENT DID NOT SUSTAIN INJURY DUE TO THE EQUIPMENT ISSUE, AND THE PROCEDURE WAS DELAYED FOR APPROXIMATELY 5-10 MINUTES WHILE THE LINKAGE COMPONENTS OF THE SUBJECT HFD100 WERE SWAPPED OUT FOR LINKAGE COMPONENTS FROM AN ALTERNATE HFD100 AT THE CUSTOMER SITE. THE CUSTOMER REPORTED THERE WAS NO SIGNIFICANT DELAY OR IMPACT ON THE PROCEDURE AND THE PATIENT TOLERATED THE PROCEDURE WELL.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16686624 ↗MalfunctionJun 1, 2022Break; Break
A CUSTOMER REPORTED THAT A TORQUE SCREW IN USE WITH AN HFD100 HEAD FIXATION DEVICE BROKE APART DURING PINNING AS PRESSURE WAS BEING APPLIED. THE CUSTOMER REPORTED NO INJURY TO THE PATIENT OCCURRED. A SECOND TORQUE SCREW WAS THEN USED IN THE HFD100 DEVICE, AFTER WHICH THE SURGICAL PROCEDURE PROCEEDED AS PLANNED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 14569826 ↗MalfunctionMay 14, 2022Unintended Movement; Unintended Movement
A CUSTOMER REPORTED THAT THE FEMALE AND MALE SKULL CLAMP COMPONENTS OF THEIR HFD100 DEVICE APPEAR TO EXHIBIT SLIGHT MOVEMENT IN RELATION TO EACH OTHER AFTER BEING FIXED WITH THE LOCKING MECHANISM. THE CUSTOMER ALSO REPORTED THIS MOVEMENT COULD IMPACT THEIR LITT CASES. NO ADVERSE PATIENT CONSEQUENCES OR PROCEDURAL OUTCOMES HAVE BEEN REPORTED IN CONNECTION WITH THIS INFORMATION. FURTHER INFORMATION AND ACCESS TO THE SPECIFIC HFD100 DEVICE AND COMPONENTS IS BEING SOUGHT FROM THE CUSTOMER TO INVESTIGATE THE CONCERN.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 14402887 ↗MalfunctionFeb 4, 2022Unintended Movement; Unintended Movement
DURING A PEDIATRIC PROCEDURE ON (B)(6) 2020, THE CUSTOMER REPORTED THAT THE HFD100 SKULL CLAMP SLIPPED. THERE WAS NO PATIENT HARM REPORTED DUE TO THE EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 13451139 ↗MalfunctionNov 1, 2021Unintended Movement; Unintended Movement
IT WAS REPORTED THAT A HEAD FIXATION DEVICE (HFD) EXHIBITED TOO MUCH PLAY DURING SET UP PRIOR TO PINNING THE PATIENT DURING A PROCEDURE. THE NEUROSURGEON DECIDED NOT TO USE THE DEVICE IN THE PROCEDURE; NO IMPACT TO THE PATIENT OR PROCEDURE WAS REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12725915 ↗
Other IMRIS Imaging, Inc. products
All IMRIS Imaging, Inc. devices →Sources and updates
- Models: FDA GUDID, file dated Oct 13, 2026. Models are grouped by the brand name the manufacturer registered.
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page