Skip to content

HOTLlNE Disposable Administration Sets recallZ-0424-2012 · Smiths Medical ASD, Inc. · initiated Nov 21, 2011

Terminated All recalls posted in January 2012

Is my device affected?

  1. Compare the model, catalog and lot or serial numbers on your device or its packaging with the code information below. A recall usually covers only specific models or lots.
  2. If yours is listed, follow the instructions from Smiths Medical ASD, Inc. or your healthcare provider. The company's action is summarized under what the company is doing.
  3. Do not stop using a prescribed or implanted device on your own — talk to your healthcare provider first.

Where to find your model and lot numbers · What recall classes and statuses mean

Why it was recalled

Disconnected/ loose Luer connectors at the patient end of the triple lumen tubing of the HOTLlNE Disposable Administration Sets and Level 1 D/DI-60HL Normothermic IV Administration Sets

FDA root cause category: Device Design

What the company is doing

Smiths Medical notified consignees by letter dated November 28, 2011 titled: Urgent Field Safety Notice. The letter identified the affected product, the problem, and the actions to be taken. Customers were instructed to inspect inventory and segregate unused affected product. Distributors were instructed to immediately stop distributing and quarantine all inventory. The letters included a Confirmation Form to be complete and return, by fax to 781-610-9859 or by email to [email protected]. For questions consignees were instructed to contact Smiths Medical at 1781-763-9330.

Recall details

Recall number
Z-0424-2012
Recall class
Not yet classified by the FDA
Status
Terminated
Initiated by the company
Nov 21, 2011
Posted by the FDA
Jan 11, 2012
Recalling firm
Smiths Medical ASD, Inc.
Quantity
60,084 units
Product code
LGZ
FDA submissions
K911383
Distribution
Worldwide Distribution (USA) (nationwide) - Argentina, Austria, Australia, Belgium, Bahrain, Bermuda, Canada, Chile, China, Columbia, Czech Republic, Germany, Denmark, Estonia, Egypt, Finland, France, Great Britain, Guernsey, Greece, Guatemala, Hong Kong, Hungary, Indonesia, Ireland, Israel India, Iceland, Italy, Japan, South Korea, Kazakhstan, Lebanon, Luxembourg, Mexico, Malaysia, New Caledonia, Netherlands, Norway, New Zealand, Panama, Poland, Portugal, Qatar, Singapore, Sweden, Slovak Republic, South Africa, Spain, Sri Lanka, Switzerland, Taiwan, and Vatican City State.

Product description

HOTLlNE Disposable Administration Sets, Product Code L-270 Product Usage: Single patient use Sets designed for use by trained medical professionals, in conjunction with HOTLlNE Routine Flow Blood and Fluid Warmers (HL-90 and HL-290), for the warming and delivery of blood and I.V. solutions, at normothermic flow rates of 50 - 5,000 ml/hr.

Code information (models, lots, serial numbers)

Lot Numbers: 1947531 1952652 1957058 1957059 1967245 1967246 1979007 1995553 1995693 1998983 1998984 2019637 2019638 2019639 2025120 2025121 2038143 2038144 2038146 2038147 2049439 2059469 2059470 2064010 2068137 2077198 2077199 2077200 2090779

Other devices under the same FDA submission

10 devices cleared under K911383 — the recall does not name any of them by identifier. One submission often covers many models, so they may or may not be affected.

Other products in the same recall event

The FDA groups related products into one recall event (event 60516).

Sources and updates

How recalls are matched to devices · Editorial policy · Report an error on this page