Dreamtome™ Pro RX 44 M00584400Recalls & reported problems

Boston Scientific Corporation · Sphincterotome · Class 2

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
8
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 8 adverse event reports that list this exact device (DI 00191506039240), received between Aug 6, 2024 and Sep 10, 2026 — classified as 8 malfunctions.

The most frequently reported specific device problem is “Break” (4 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 1 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 1 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 1 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 1 reportsApr 2026: 1 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 1 reportsAug 2026: 0 reportsSep 2026: 2 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem4
  • Break4
  • Deformation Due to Compressive Stress2
  • Difficult to Advance1
  • Failure to Align1
  • Material Integrity Problem1
  • Material Protrusion/Extrusion1
  • Use of Device Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions8

Recent adverse event reports

The 8 most recent of 8 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 10, 2026Difficult to Advance; Material Integrity Problem

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50716932 ↗
  • MalfunctionSep 9, 2026Use of Device Problem; Deformation Due to Compressive Stress

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50695465 ↗
  • MalfunctionJul 21, 2026Break; Deformation Due to Compressive Stress; Adverse Event Without Identified Device or Use Problem

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25892857 ↗
  • MalfunctionApr 29, 2026Break; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT A DREAMTOME PRO RX 44 WAS ATTEMPTED TO BE USED IN THE COMMON BILE DUCT DURING AN ENDOSCOPIC RETROGRADE CHOLANGIOPANCREATOGRAPHY (ERCP) PROCEDURE PERFORMED ON AN UNKNOWN DATE. DURING THE PROCEDURE, A SPHINCTEROTOME BROKE. THEY HAD HARDLY USED IT TO CUT WHEN THE WIRE BROKE. IT WAS REPORTED THAT NO PART OF THE CUTTING WIRE WAS DETACHED AND FELL INTO THE PATIENT. THE PROCEDURE WAS COMPLETED WITH ANOTHER OF THE SAME DEVICE. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25037059 ↗
  • MalfunctionMar 9, 2026Break; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT A DREAMTOME PRO RX 44 WAS ATTEMPTED TO BE USED DURING A SPHINCTEROTOMY PROCEDURE PERFORMED ON (B)(6) 2026. DURING THE PROCEDURE, THE CUTTING WIRE BROKE. THE PROCEDURE WAS COMPLETED WITH ANOTHER OF THE SAME DEVICE. THERE WERE NO REPORTED PATIENT COMPLICATIONS AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24545564 ↗
  • MalfunctionAug 19, 2025Material Protrusion/Extrusion

    FROM STAFF: PATIENT WAS HAVING A ERCP [ENDOSCOPIC RETROGRADE CHOLANGIOPANCREATOGRAPHY] WITH DR [REDACTED]. DURING THE PROCEDURE THE WIRE WAS EXPOSED THROUGH THE WIRE COVERING. PATIENT WASN'T HARMED NOR DAMAGE TO THE SCOPE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22838133 ↗
  • MalfunctionNov 5, 2024Failure to Align; Failure to Align

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT A DREAMTOME PRO RX 44 SPHINCTEROTOME WAS USED IN THE BILE DUCT DURING AN ENDOSCOPIC RETROGRADE CHOLANGIOPANCREATOGRAPHY (ERCP) PROCEDURE PERFORMED ON (B)(6) 2024. DURING THE PROCEDURE, AFTER BOWING THE TOME, IT BECAME UNABLE TO BE RELAXED AND REMAINED STUCK IN THE BOWED POSITION. THE NURSE DOES NOT BELIEVE IT WAS CAUGHT ON THE SCOPE OR ELEVATOR, AND DESPITE SEVERAL ATTEMPTS, SHE WAS UNABLE TO RELAX THE DEVICE. THE PROCEDURE WAS COMPLETED WITH ANOTHER DREAMTOME PRO RX 44 SPHINCTEROTOME. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20605895 ↗
  • MalfunctionAug 6, 2024Break; Adverse Event Without Identified Device or Use Problem; Break; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT A DREAMTOME PRO RX 44 SPHINCTEROTOME WAS USED IN THE MAJOR PAPILLA DURING AN ENDOSCOPIC RETROGRADE CHOLANGIOPANCREATOGRAPHY (ERCP) PROCEDURE PERFORMED ON (B)(6) 2024. DURING THE PROCEDURE, THE CUTTING WIRE OF SNAPPED DURING THE SPHINCTEROTOMY AND "THE WIRE APPEARS TO HAVE BEEN SEPARATED FROM THE BLUE INSULATED SECTION." IT WAS REPORTED THAT NO PART OF THE CUTTING WIRE DETACHED AND FELL INTO THE PATIENT. THE PROCEDURE WAS COMPLETED WITH ANOTHER OF THE SAME DEVICE. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19915193 ↗

Other Unit, electrosurgical, endoscopic (with or without accessories) devices

All Unit, electrosurgical, endoscopic (with or without accessories) devices →