Revolution AdvanceRecalls & reported problems

GE Hangwei Medical Systems Company Ltd. · Revolution Advance designated medical device · Class 2

All models of Revolution (10)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

3 open recalls name this device. See the recall details and contact the manufacturer or your healthcare provider.

Adverse event reports
0
Deaths reported
0
Injuries reported
0
Recalls naming it
3

Summary

No MAUDE adverse event reports in our data reference this device identifier directly.

3 FDA recall records name this device's identifier, 3 still open.

4 other recalls cover devices cleared under the same FDA submission (K123596); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Recalls naming this device

  1. Nov 5, 2024Class IIOpen, Classified

    GE HealthCare has become aware of a potential issue on certain Discovery, Optima, Revolution series CT systems, and certain operator console upgrades that can result in rotated CT images. Particularly with helical, cine, and cardiac (if applicable) scan modes, after the first image of an exam, each subsequent image can be rotated by an increasing amount. The amount of progressive image rotation is dependent on the gantry speed and the duration of the scan. The final image in the exam can be rotated up to a maximum of ~56 degrees. The entire anatomy rotates as a whole by equal degrees, without distortion, and the anatomical positioning and z-axis of the images remains correct. Small degrees of image rotation might not be noticed. If image rotation is noticed and necessitates a rescan of the patient, the same image rotation will reoccur.

    Z-0604-2025 · Root cause: Component design/selection · Recall details · FDA record ↗

  2. Nov 5, 2024Class IIOpen, Classified

    GE HealthCare has become aware of a potential issue on certain Discovery, Optima, Revolution series CT systems, and certain operator console upgrades that can result in rotated CT images. Particularly with helical, cine, and cardiac (if applicable) scan modes, after the first image of an exam, each subsequent image can be rotated by an increasing amount. The amount of progressive image rotation is dependent on the gantry speed and the duration of the scan. The final image in the exam can be rotated up to a maximum of ~56 degrees. The entire anatomy rotates as a whole by equal degrees, without distortion, and the anatomical positioning and z-axis of the images remains correct. Small degrees of image rotation might not be noticed. If image rotation is noticed and necessitates a rescan of the patient, the same image rotation will reoccur.

    Z-0607-2025 · Root cause: Component design/selection · Recall details · FDA record ↗

  3. Jun 2, 2022Class IIOpen, Classified

    As a result of unclear guidance in the service manual, the table can drop during a specific service activity if the wrong screws are removed by the service personnel without the appropriate table supports in place resulting in injury to service personnel.

    Z-1511-2022 · Root cause: Error in labeling · Recall details · FDA record ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K123596. One submission often covers many models, so check the product and lot details in each record.

  • Z-0601-2025 · Nov 5, 2024 · Open, Classified
    GE Healthcare Optima 520, Catalog number 5439126; X-ray/computed tomography systems
  • Z-2585-2018 · May 24, 2018 · Terminated
    Optima CT 520
  • Z-2185-2017 · May 19, 2017 · Terminated
    GE Healthcare Optima CT520 X-ray system
  • Z-0840-2014 · Oct 9, 2013 · Terminated
    GE Optima CT520 and Optima CT540 Computed Tomography (CT) systems. Intended to produce cross-sectional images of the body by computer reconstruction of x-ray transmission data t

Other System, x-ray, tomography, computed devices

All System, x-ray, tomography, computed devices →