CapSureFix Novus MRI™ SureScan® 5076-85 (UDI 00643169448926)Recalls & reported problems

Medtronic, Inc. · LEAD 5076-85 MRI US EIFU · Class 3 · Implant

All models of CapSureFix Novus MRI SureScan (29)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00643169448926), received between Dec 9, 2016 and Oct 27, 2022 — classified as 2 malfunctions.

The most frequently reported specific device problem is “Connection Problem” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Most reported problems

Device problems

  • Connection Problem1
  • Positioning Problem1

Patient problems

  • No Known Impact Or Consequence To Patient1
  • Scar Tissue1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionOct 27, 2022Connection Problem; Connection Problem

    THE PATIENT REPORTED THAT, APPROXIMATELY THREE MONTHS POST GENERATOR AND EPICARDIAL LEFT VENTRICULAR (LV) LEAD CHANGEOUT, THEY EXPERIENCED, "TOO MUCH," SCAR TISSUE FORMED DUE TO, "SO MANY," SURGERIES AND INTERFERED WITH THE IMPLANTABLE PULSE GENERATOR (IPG) SYSTEM CONNECTIVITY. THE IPG SYSTEM REMAINS IN USE. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: Scar Tissue

    MAUDE report 15678696 ↗
  • MalfunctionDec 9, 2016Positioning Problem; Positioning Problem

    IT WAS REPORTED THAT THE RIGHT VENTRICULAR (RV) LEAD WAS ATTEMPTED, NOT IMPLANTED. THE PHYSICIAN HAD TROUBLE MANEUVERING THE LEAD, ADVANCING STYLETS, AND PLACING THE LEAD APPROPRIATELY. DUE TO THE LEAD NOT BEING COMMON LENGTH NO ADDITIONAL STYLETS WERE AVAILABLE TO ASSIST IN FURTHER ATTEMPTS TO PLACE THE LEAD. A NEW LENGTH OF LEAD WAS IMPLANTED AND REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 6164536 ↗

Other Permanent defibrillator electrodes devices

All Permanent defibrillator electrodes devices →