MiniMed® 670G MMT-1760KPK (UDI 00643169946057)Recalls & reported problems
Medtronic Minimed, Inc. · KIT MMT-1760KPK 670G V3.18 EN MG · Class 3
All models of MiniMed 670G (23)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
3 open recalls name this device. See the recall details and contact the manufacturer or your healthcare provider.
- Adverse event reports
- 10
- Deaths reported
- 0
- Injuries reported
- 5
- Recalls naming it
- 3
Summary
The FDA's MAUDE database contains 10 adverse event reports that list this exact device (DI 00643169946057), received between Jan 4, 2018 and Jul 28, 2020 — classified as 5 injuries, 5 malfunctions.
The most frequently reported specific device problem is “Patient Device Interaction Problem” (4 reports).
3 FDA recall records name this device's identifier, 3 still open.
11 other recalls cover devices cleared under the same FDA submission (P160017); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Recalls naming this device
- Feb 13, 2026Class IIOpen, Classified
All Medtronic MiniMed infusion pumps (Paradigm series, 600 series, and BLE 700 series) were found to be affected by unintended over- and under-delivery of insulin when the pump is elevated or lowered relative to the infusion site, respectively, because of changes in gravitational force impacting hydrostatic and hydrodynamic pressures. Insulin over-delivery, which can occur when the pump is elevated relative to the infusion site, can result in severe hypoglycemia, altered mental status, seizure, coma, or death. An under-delivery of insulin, which can occur at lowered pump height conditions relative to the infusion site, can result in severe hyperglycemia, dehydration, diabetic ketoacidosis, or death.
Z-1739-2026 · Root cause: Device Design · Recall details · FDA record ↗
- Jul 31, 2024Class IOpen, Classified
Insulin pumps that have been dropped, bumped, or experienced physical impact may have damage to internal electrical components, which may cause reduced pump battery life. Since the defect reduces the battery life overall, it shortens the time between low battery alarms and increases the frequency with which the user must insert a new battery. Further, the defect may also deliver the low battery alarm when there is significantly less time before the battery completely runs out, from the expected up to 10-hour buffer the low alert is supposed to signal, leading to device powering down and stopping insulin delivery unexpectedly. Per the firm, a subset of pumps with the defect showed the low alert alarm was delivered ~2.5 hours before the device shut off, however, patient reports indicate the time could be even shorter. Replacing the battery will not resolve this issue and the short battery life and the truncated low battery alert lead time will continue to occur. Early battery depletion could result in power loss and insulin delivery could be interrupted, resulting in under delivery of insulin potentially leading to hyperglycemia and/or DKA.
Z-0003-2025 · Root cause: Device Design · Recall details · FDA record ↗
- Sep 20, 2022Class IIOpen, Classified
Medtronic identified a cybersecurity vulnerability in the MiniMed 600 series Insulin Pump Systems associated with the communication protocol that could allow unauthorized access to the pump system. This unauthorized access could be used to deliver too much or too little insulin through delivery of an unintended insulin bolus or because insulin delivery is slowed or stopped, which could lead to hypoglycemia or hyperglycemia. The Remote Bolus feature on insulin pumps should be turned off to prevent the unauthorized access.
Z-0193-2023 · Root cause: Component change control · Recall details · FDA record ↗
Most reported problems
Device problems
- Patient Device Interaction Problem4
- Adverse Event Without Identified Device or Use Problem2
- Connection Problem2
- Defective Component1
- Device Operates Differently Than Expected1
- Electrical /Electronic Property Problem1
- Improper or Incorrect Procedure or Method1
- Leak/Splash1
Patient problems
- No Consequences Or Impact To Patient5
- Hyperglycemia4
- Hypoglycemia1
- Loss of consciousness1
Recent adverse event reports
The 10 most recent of 10 reports, in the reporter's own words as published by the FDA.
MalfunctionJul 28, 2020Connection Problem; Patient Device Interaction Problem; Connection Problem; Patient Device Interaction Problem
INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT THE RETAINER RING WAS BROKEN. TROUBLESHOOTING WAS DONE FOR COSMETIC DAMAGE. THE RESERVOIR WAS UNABLE TO LOCK IN PLACE WHEN INSERTED INTO INSULIN PUMP. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE INSULIN PUMP WILL NOT BE RETURNED FOR ANALYSIS.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10333813 ↗MalfunctionJun 2, 2020Patient Device Interaction Problem; Patient Device Interaction Problem
INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT THE RETAINER RING WAS LOOSENED. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE INSULIN PUMP WILL BE RETURNED FOR ANALYSIS.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10109052 ↗MalfunctionMar 12, 2020Connection Problem; Patient Device Interaction Problem; Connection Problem; Patient Device Interaction Problem
INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT THE INSULIN PUMP HAD A MISSING RETAINER RING. THE CUSTOMER STATED THAT THE RESERVOIR DOES NOT LOCK INTO PLACE, RESULTING IN THE RESERVOIR FALLING OUT OF THE PUMP OR THE PUMP GIVING HER THE INCORRECT AMOUNT OF INSULIN. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE INSULIN PUMP WILL NOT BE RETURNED FOR ANALYSIS.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9823022 ↗InjuryFeb 21, 2020Leak/Splash; Loose or Intermittent Connection; Nonstandard Device; Defective Component
I WAS ON A BUSINESS TRIP TO (B)(6). I WAS STAYING IN A HOTEL WITH AN EMPLOYEE IN ANOTHER ROOM. WHEN I DIDN'T SHOW UP FOR BREAKFAST AND THEN A FOLLOWING MEETING THE EMPLOYEE BECAME CONCERNED AND EVENTUALLY CALLED POLICE WHEN I WOULDN'T ANSWER MY PHONE. THE POLICE ENDED UP KICKING MY DOOR IN WHEN THEY NOTICED FROM A CRACK IN THE CURTAINS THAT I WAS LAYING IN BED UNCONSCIOUS. THE PARAMEDICS CAME AND INJECTED ME WITH GLUCAGON AND I WAS REVIVED. ONE OF THE PARAMEDICS TOLD ME THAT I HAD ROLLED OVER ON MY PUMP AND HAD ACCIDENTALLY LET ALL OF THE INSULIN OUT OF MY PUMP. I TOLD HIM THAT WAS IMPOSSIBLE AND HE SAID HE SEES IT ALL THE TIME. I SAID NO I JUST FILLED UP THE RESERVOIR A DAY AGO BECAUSE I DIDN'T WANT TO BE DEALING WITH THAT WHILE TRAVELING. HE PICKED UP THE PUMP AND SHOWED IT TO ME AND THE RESERVOIR WAS OUT OF INSULIN. I HAD BEEN TOTALLY RACKING MY BRAIN AS TO HOW THAT COULD HAPPEN TILL I SAW ON THE NEWS THAT MY MEDTRONIC MINIMED PUMP WAS ON A LIST OF PUMP BEING RECALLED. THE RECALL STATED THAT IT WAS BECAUSE OF A DEFECTIVE O RING THAT COULD BECOME DAMAGED. I HAVE THE MINIMED 670G AFTER I SAW THE RECALL ON THE TV, I CALLED THE COMPANY AND THEY CONFIRMED THAT MY PUMP WAS INCLUDED IN
Patient problems: Hypoglycemia; Loss of consciousness
MAUDE report 9744552 ↗MalfunctionJan 23, 2020Electrical /Electronic Property Problem; Power Problem; Patient Device Interaction Problem; Electrical /Electronic Property Problem; Power Problem; Patient Device Interaction Problem
INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT THE INSULIN PUMP HAD PUMP ERROR ALARM. CUSTOMER REPORTED THAT THE INSULIN PUMP SHOWS FAILED BATTERY TEST THE INSULIN PUMP TURNS OFF THEN RESTARTS HE WAS USING BRAND NEW BATTERIES HE EVEN USED 3 BATTERIES. CONTACTS WAS NOT MISSING, DAMAGED, OR CORRODED. CUSTOMER WAS ABLE TO SUCCESSFULLY CLEAR THE ALARM. CUSTOMER WAS UNABLE TO COMPLETE INSULIN PUMP REWIND. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE INSULIN PUMP WILL NOT BE RETURNED FOR ANALYSIS.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9619839 ↗InjuryNov 13, 2019Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE CUSTOMER EXPERIENCED HIGH BLOOD GLUCOSE LEVEL. CUSTOMER¿S BLOOD GLUCOSE LEVEL WAS BETWEEN 300 MG/DL - 400 MG/DL AND ALSO BETWEEN 357 MG/DL ¿ 418 MG/DL. CUSTOMER'S OTHER RELEVANT BLOOD GLUCOSE LEVEL WAS 168 MG/DL AFTER TREATMENT WITH INSULIN PUMP. CUSTOMER ALSO REPORTED THAT THE INFUSION SET CANNULA WAS BENT. THE INSULIN PUMP WILL NOT BE RETURNED FOR ANALYSIS.
Patient problems: Hyperglycemia
MAUDE report 9315671 ↗MalfunctionAug 29, 2019Mechanical Problem; Mechanical Problem
IT WAS REPORTED THAT THE CUSTOMER WAS IN THE WATER WHEN THE INSULIN PUMP HAD AN INSULIN PUMP ALARM. THE CUSTOMER'S BLOOD GLUCOSE LEVEL WAS 170 MG/DL AT THE TIME OF THE INCIDENT. THE CUSTOMER REPORTED THAT WAS UNABLE TO CLEAR THE ALARM. THE CUSTOMER WAS ADVISED TO REVERT TO THE BACK-UP PLAN AS PER THE HEALTHCARE PROFESSIONALS. THE DEVICE WILL NOT BE RETURNED FOR ANALYSIS.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8948299 ↗InjuryMar 5, 2018Device Operates Differently Than Expected
THE CUSTOMER REPORTED VIA PHONE CALL THAT THE CUSTOMER HAD HIGH BLOOD GLUCOSE LEVEL. THE CUSTOMER¿S BLOOD GLUCOSE LEVEL WAS OVER 500 MG/DL. THE CUSTOMER ALSO REPORTED ISSUE WITH INFUSION SET. THE INSULIN PUMP WILL NOT BE RETURNED FOR ANALYSIS.
Patient problems: Hyperglycemia
MAUDE report 7313394 ↗InjuryFeb 7, 2018Adverse Event Without Identified Device or Use Problem
CUSTOMER REPORTED VIA PHONE CALL THAT THEY EXPERIENCED HIGH BLOOD GLUCOSE LEVEL. CUSTOMER'S BLOOD GLUCOSE VALUE WAS 524 MG/DL AT THE TIME OF THE INCIDENT AND STATED ADVERSE EVENT WITH A DIAGNOSIS OF SEVERE HYPERGLYCEMIA. THE CUSTOMER WAS TREATED WITH SYRINGE AND MANUAL INJECTION. CUSTOMER WILL NOT RETURN DEVICE FOR ANALYSIS.
Patient problems: Hyperglycemia
MAUDE report 7248925 ↗InjuryJan 4, 2018Improper or Incorrect Procedure or Method
CUSTOMER (PRIMARY INVESTIGATOR) REPORTED FOR PATIENT VIA PHONE CALL FOR HIGH BLOOD GLUCOSE. BLOOD GLUCOSE WAS 589 MG/DL. CUSTOMER HAD A DEVICE RELATED ADVERSE EVENT WITH A DIAGNOSIS OF SEVERE HYPERGLYCEMIA. CUSTOMER REPORTED THAT EVENT WAS MODERATE IN NATURE AND THE SUBJECT RECOVERED WITHOUT SEQUELE. CUSTOMER REPORTED MOM CONTACTED CDE AND STATED THAT SHE CHANGED OUT CARTRIDGE AND FORGOT TO REWIND IT FIRST AND PATIENT DID NOT GET ANY INSULIN FOR A LARGE LUNCH AND JUST REALIZED MISSING BASAL ALSO ,BLOOD GLUCOSE WAS 589 MG/DL WITH BLOOD KETONES OF 2.2 MMOL. CUSTOMER REPORTED THAT MOM GAVE CORRECTION SHOT AND WITHIN 3 HOURS BLOOD GLUCOSE WAS 313 MG/DL AND BLOOD KETONES WERE AT 0.2 MMOL. CUSTOMER REPORTED THAT PATIENT DID NOT VOMIT OR GET SICK. THE PUMP WILL NOT BE RETURNED FOR ANALYSIS.
Patient problems: Hyperglycemia
MAUDE report 7166286 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under P160017. One submission often covers many models, so check the product and lot details in each record.
- Z-2981-2026 · Jul 13, 2026 · Open, ClassifiedMiniMed 670G Insulin Pump, Model: MMT-1781, MMT-1782;
- Z-1742-2026 · Feb 13, 2026 · Open, ClassifiedMiniMed 770G Insulin Pump (MMT-1880, MMT-1881, MMT-1882, MMT-1890, MMT-1891, MMT-1892)
- Z-1261-2025 · Jan 31, 2025 · Open, ClassifiedMiniMed insulin pump, REF: 670G (MMT-1760, MMT-1761, MMT-1762, MMT-1780, MMT-1781, MMT-1782)
- Z-1266-2025 · Jan 31, 2025 · Open, ClassifiedMiniMed insulin pump, REF: 780G (MMT-1884, MMT-1885, MMT-1886, MMT-1894, MMT-1895, MMT-1896)
- Z-1265-2025 · Jan 31, 2025 · Open, ClassifiedMiniMed insulin pump, REF: 770G (MMT-1880, MMT-1881, MMT-1882, MMT-1890, MMT-1891, MMT-1892)
- Z-0855-2022 · Jan 27, 2022 · Open, ClassifiedMiniMed 630G: MMT-1715, MMT-1754, MMT-1755; MiniMed 670G: MMT-1740, MMT-1741, MMT-1742, MMT-1760, MMT-1761, MMT-1762, MMT-1780, MMT-1781, MMT-1782; MiniMed 770G: MMT-1880, MMT-1881
- Z-1771-2021 · Mar 15, 2021 · Open, ClassifiedMiniMed 780G Insulin Pump: Models: PUMP MMT-1885 MM780G 6.5V BLE MMOL; PUMP MMT-1886 MM780G 6.5W BLE MG; KIT MMT-1895WW MM780G 6.5V BLE SF MMOL; KIT MMT-1896WW MM780G 6.5W BLE SF M
- Z-0516-2021 · Apr 30, 2020 · Open, ClassifiedMiniMed 670G, insulin pump, Ref/Model # MMT-1760KPK, MMT-1762KCN, MMT-1762WWK - Product Usage: indicated for continuous or periodic monitoring of glucose levels in the fluid under
- Z-0956-2020 · Nov 21, 2019 · Open, ClassifiedMedtronic MiniMed 670G System with SmartGuard, Ref #s/Model Number(s) - MMT-1741, MMT-1742, MMT-1760, MMT-1761, MMT-1762, MMT-1580, MMT-1581, MMT-1582, MMT-1780, MMT-1781, and MM
- Z-2605-2017 · May 8, 2017 · TerminatedMiniMed 670G Insulin Infusion Pump, Catalog No. MMT-1580, MMT-1780, MMT-1782, MMT-1760.
- Z-2604-2017 · May 8, 2017 · TerminatedMiniMed 640G Insulin Infusion Pump, Catalog No. MMT-1511, MMT-1711, MMT-1512, MMT-1712, MMT-1551, MMT-1751, MMT-1552, MMT-1752.
Other Artificial pancreas device system, single hormonal control devices
- MiniMed® 670G MMT-1780KPKMedtronic Minimed, Inc. · Artificial pancreas device system, single hormonal control3 recalls78 deaths55,723 reports
- MiniMed® 670G MMT-1780KPKMedtronic Minimed, Inc. · Automated insulin dosing device system, single hormonal control2 recalls51 deaths33,713 reports
- MiniMed®670G MMT-1780KPKMedtronic Minimed, Inc. · Artificial pancreas device system, single hormonal control3 recalls39 deaths28,789 reports
- MiniMed® 670G MMT-1780KLMedtronic Minimed, Inc. · Automated insulin dosing device system, single hormonal control3 recalls8 deaths8,353 reports
- MiniMed® 670G MMT-1780KMedtronic Minimed, Inc. · Artificial pancreas device system, single hormonal control3 recalls7 deaths6,776 reports
- MiniMed® 670G MMT-1780KPKMedtronic Minimed, Inc. · Automated insulin dosing device system, single hormonal control3 recalls10 deaths4,325 reports
- MiniMed™ Reservoir MMT-332AMedtronic Minimed, Inc. · Automated insulin dosing device system, single hormonal control2 deaths3,013 reports
- Guardian™ Sensor (3) MMT-7020AMedtronic Minimed, Inc. · Automated insulin dosing device system, single hormonal control1,304 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026 · each recall links to the FDA recall notice
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page