Tri-Tome pc G22556Recalls & reported problems
Cook Incorporated · Tri-Tome PC Triple Lumen Sphincterotome · Class 2
All models of Tri-Tome pc (8)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00827002225565), received between May 27, 2016 and May 18, 2018 — classified as 4 malfunctions.
The most frequently reported specific device problem is “Failure to Align” (4 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Failure to Align4
Patient problems
- No Consequences Or Impact To Patient4
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
MalfunctionMay 18, 2018Failure to Align; Failure to Align
DURING AN ENDOSCOPIC RETROGRADE CHOLANGIOPANCREATOGRAPHY (ERCP) PROCEDURE, THE WIRE GUIDE WAS PLACED INTO BILE DUCT SUCCESSFULLY AND CALCULUS WAS DETECTED THROUGH RADIOGRAPHY. THE USER [TRIED TO] USE TRI-TOME PC TRIPLE LUMEN SPHINCTEROTOME TO CUT THE DUODENAL PAPILLARY AND FOUND OUT THE PROXIMAL CUTTING WIRE TWISTED [INCORRECT CUTTING WIRE ORIENTATION]. THE USER FEELS THE HANDLE IS VERY STIFF TO PULL THE CUTTING WIRE.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 7525991 ↗MalfunctionJul 10, 2017Failure to Align; Failure to Align
DURING AN ENDOSCOPIC PROCEDURE, THE PHYSICIAN USED FOUR (4) COOK TRI-TOME PC TRIPLE LUMEN SPHINCTEROTOMES. THE ISSUE IS WITH FOUR (4) UNITS OF TRI-30 FROM LOT W3851875. WHEN YOU SLIGHTLY BEND THE SPHINCTEROTOME, IT DOES NOT BEND STRAIGHT, BUT GOES VERY MUCH TO THE RIGHT. IT IS TOTALLY IMPOSSIBLE TO GET INTO THE PAPILLA [INCORRECT CUTTING WIRE ORIENTATION].
Patient problems: No Consequences Or Impact To Patient
MAUDE report 6697712 ↗MalfunctionJun 2, 2017Failure to Align; Failure to Align
DURING AN ENDOSCOPIC RETROGRADE CHOLANGIOPANCREATOGRAPHY (ERCP), THE PHYSICIAN USED TWO (2) COOK TRI-TOME PC TRIPLE LUMEN SPHINCTEROTOMES. THE CUTTING WIRE WAS NOT PROPERLY ALIGNED WITH THE CATHETER AND THEREFORE WHEN HE [THE PHYSICIAN] WANTS TO CUT, THE CUTTING [WIRE] IS NOT STRAIGHT AND GOES IN AN INCORRECT DIRECTION [INCORRECT CUTTING WIRE ORIENTATION]. [BOTH DEVICES WERE USED ON THE] SAME PATIENT.
Patient problems: No Consequences Or Impact To Patient; No Known Impact Or Consequence To Patient
MAUDE report 6608591 ↗MalfunctionMay 27, 2016Failure to Align; Failure to Align
PER COMPLAINT EMAIL: "PHYSICIANS REPORT THAT THE DISTAL TIP DOESN'T HAVE THE ORIENTATION THAT THEY NEEDED." THIS WAS INITIALLY REPORTED TO BE PRIOR TO USE. ON 05/04/2016, WE RECEIVED THE FOLLOWING INFORMATION: THE MISORIENTATION WAS NOTED BEFORE AND AFTER INSERTING THE SPHINCTEROTOME INTO THE ENDOSCOPE.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 5684872 ↗
Other Unit, electrosurgical, endoscopic (with or without accessories) devices
- THUNDERBEAT 5 mm, 35 cm, Front-actuated Grip TB-0535FCOlympus Medical Systems Corp. · Unit, electrosurgical, endoscopic (with or without accessories)1 recall2 deaths404 reports
- SONICBEAT 5 mm, 35 cm, Front-actuated Grip SB-0535FCOlympus Medical Systems Corp. · Unit, electrosurgical, endoscopic (with or without accessories)379 reports
- Single Use Electrosurgical Knife KD-611LOlympus Medical Systems Corp. · Unit, electrosurgical, endoscopic (with or without accessories)1 death357 reports
- Autotome™ RX 44 M00545170Boston Scientific Corporation · Unit, electrosurgical, endoscopic (with or without accessories)1 recall262 reports
- TRUEtome 44 M00584170Boston Scientific Corporation · Unit, electrosurgical, endoscopic (with or without accessories)237 reports
- Dreamtome™ RX 44 M00584040Boston Scientific Corporation · Unit, electrosurgical, endoscopic (with or without accessories)1 recall165 reports
- Dreamtome™ RX 44 M00584050Boston Scientific Corporation · Unit, electrosurgical, endoscopic (with or without accessories)1 recall127 reports
- Single Use 3-Lumen Sphincterotome V KD-V411M-0725Olympus Medical Systems Corp. · Unit, electrosurgical, endoscopic (with or without accessories)160 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page