Acusnare G22632Recalls & reported problems

Cook Incorporated · Acusnare Polypectomy Snare Soft · Class 2

Data updated Oct 13, 2026 from official FDA records · Editorial policy

Adverse event reports
21
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 21 adverse event reports that list this exact device (DI 00827002226326), received between Sep 27, 2017 and May 6, 2026 — classified as 21 malfunctions.

The most frequently reported specific device problem is “Failure to Conduct” (9 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 1 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 2 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 2 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 1 reportsJun 2025: 0 reportsJul 2025: 1 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 1 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Failure to Conduct9
  • Deformation Due to Compressive Stress5
  • Material Frayed2
  • Retraction Problem2
  • Break1
  • Fracture1
  • Material Deformation1
  • Material Separation1

Patient problems

  • No Consequences Or Impact To Patient11
  • No Clinical Signs, Symptoms or Conditions8
  • Device Embedded In Tissue or Plaque1
  • No Patient Involvement1

Recent adverse event reports

The 21 most recent of 21 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMay 6, 2026Material Frayed

    DURING AN ASCENDING COLON POLYP REMOVAL, THE PHYSICIAN USED A COOK ACUSNARE POLYPECTOMY SNARE. IT WAS REPORTED [THAT] THE WIRE AT THE DISTAL END OF THE SNARE WAS FOUND TO BE FRACTURED. THE DEVICE WAS IMMEDIATELY REPLACED WITH A NEW COOK SNARE AND THE POLYPECTOMY WAS COMPLETED. THERE WAS NO REPORTABLE INFORMATION AT THIS TIME. THE DEVICE WAS EVALUATED ON 10APR2026. IT WAS DETERMINED THAT THE SNARE TIP WAS FRAYED AND THE DEVICE WAS BARELY ABLE TO CUT/COAGULATE THE TISSUE [SUBJECT OF REPORT]. A SECTION OF THE DEVICE DID NOT REMAIN INSIDE THE PATIENT¿S BODY. THE PATIENT DID NOT REQUIRE ANY ADDITIONAL PROCEDURES DUE TO THIS OCCURRENCE. ACCORDING TO THE INITIAL REPORTER, THE PATIENT DID NOT EXPERIENCE ANY ADVERSE EFFECTS DUE TO THIS OCCURRENCE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25094910 ↗
  • MalfunctionJul 2, 2025Off-Label Use; Off-Label Use

    DURING A POLYP REMOVAL, THE PHYSICIAN USED A COOK ACUSNARE POLYPECTOMY SNARE SOFT. IT WAS REPORTED [THAT] USER DETECTED THAT THE SNARE WAS NOT SHARP AND UNABLE TO REMOVE POLYP. USER CHANGED TO A NEW SNARE TO COMPLETE THE PROCEDURE. A SECTION OF THE DEVICE DID NOT REMAIN INSIDE THE PATIENT¿S BODY. THE PATIENT DID NOT REQUIRE ANY ADDITIONAL PROCEDURES DUE TO THIS OCCURRENCE. ACCORDING TO THE INITIAL REPORTER, THE PATIENT DID NOT EXPERIENCE ANY ADVERSE EFFECTS DUE TO THIS OCCURRENCE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22386909 ↗
  • MalfunctionMay 2, 2025Deformation Due to Compressive Stress; Deformation Due to Compressive Stress

    DURING AN ENTEROSCOPY INSPECTION IN COLON, THE PHYSICIAN USED A COOK ACUSNARE POLYPECTOMY SNARE SOFT. IT WAS REPORTED [THAT] USER OPENED THE PACKAGE AND ADVANCED THE DEVICE INTO INTESTINAL TRACT THROUGH ENDOSCOPE WORKING CHANNEL. WHEN READYING TO OPEN THE SNARE, IT WAS FOUND THAT THERE WAS GREAT RESISTANCE AND THE SUPPORTING SHEATH DEFORMED. USER RETRACTED THE DEVICE AND ENDOSCOPE, AND CHANGED TO ANOTHER DEVICE TO COMPLETE THE PROCEDURE. FURTHER INFORMATION DETERMINED THAT THE SNARE WAS DIFFICULT TO RETRACT. A SECTION OF THE DEVICE DID NOT REMAIN INSIDE THE PATIENT¿S BODY. THE PATIENT DID NOT REQUIRE ANY ADDITIONAL PROCEDURES DUE TO THIS OCCURRENCE. ACCORDING TO THE INITIAL REPORTER, THE PATIENT DID NOT EXPERIENCE ANY ADVERSE EFFECTS DUE TO THIS OCCURRENCE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21950830 ↗
  • MalfunctionJan 3, 2025Failure to Conduct; Failure to Conduct

    DURING A COLONOSCOPY , THE PHYSICIAN USED A COOK ACUSNARE POLYPECTOMY SNARE SOFT. AFTER PUTTING SCOPE IN, THEY USED SNARE TO TRY TO CUT THE POLYP BUT IT WOULD NOT CUT. THE REP ASKED THEM TO TRY A DIFFERENT ACTIVE CORD. THEY SWITCHED THE CORD AND CUT THROUGH POLYP. THE PROCEDURE WAS SUCCESSFULLY COMPLETED WITH THE SNARE AND THE NEW ACTIVE CORD. A SECTION OF THE DEVICE DID NOT REMAIN INSIDE THE PATIENT¿S BODY. THE PATIENT DID NOT REQUIRE ANY ADDITIONAL PROCEDURES DUE TO THIS OCCURRENCE. ACCORDING TO THE INITIAL REPORTER, THE PATIENT DID NOT EXPERIENCE ANY ADVERSE EFFECTS DUE TO THIS OCCURRENCE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21072177 ↗
  • MalfunctionJan 3, 2025Failure to Conduct; Failure to Conduct

    DURING A COLONOSCOPY, THE PHYSICIAN USED A COOK ACUSNARE POLYPECTOMY SNARE SOFT. IT WAS REPORTED [THAT] THEY PUT THE FIRST SNARE AROUND THE LARGE POLYP AND TRIED TO CUT THE POLYP OFF. THE SNARE WOULD NOT CUT THROUGH THE POLYP. THE SNARE THEN REMAINED STUCK ON THE POLYP. THEY COULD NOT GET THE SNARE OFF THE POLYP. SO, THEY CUT THE HANDLE OFF THE SNARE SO THEY COULD REMOVE THE SCOPE. THE SNARE LOOP WAS STILL STUCK IN THE PATIENT AND THE SCOPE WAS OUT. A SECTION OF THE DEVICE DID NOT REMAIN INSIDE THE PATIENT¿S BODY. THE SNARE LOOP LODGED ON POLYP WAS RETRIEVED WITH ANOTHER SNARE TO REMOVE POLYP DUE TO THIS OCCURRENCE. ACCORDING TO THE INITIAL REPORTER, THE PATIENT DID NOT EXPERIENCE ANY ADVERSE EFFECTS DUE TO THIS OCCURRENCE.

    Patient problems: Device Embedded In Tissue or Plaque

    MAUDE report 21072175 ↗
  • MalfunctionSep 3, 2024Failure to Conduct; Failure to Conduct

    DURING AN UNKNOWN ENDOSCOPIC PROCEDURE, THE PHYSICIAN USED A COOK ACUSNARE POLYPECTOMY SNARE SOFT. IT WAS REPORTED [THAT] SNARE [WAS] MELTING CLOSE TO HANDLE, SWITCHED CAUTERY MACHINE, AND SAME THING HAPPENED. A SECTION OF THE DEVICE DID NOT REMAIN INSIDE THE PATIENT¿S BODY. THE PATIENT DID NOT REQUIRE ANY ADDITIONAL PROCEDURES DUE TO THIS OCCURRENCE. ACCORDING TO THE INITIAL REPORTER, THE PATIENT DID NOT EXPERIENCE ANY ADVERSE EFFECTS DUE TO THIS OCCURRENCE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20127666 ↗
  • MalfunctionSep 3, 2024Failure to Conduct; Failure to Conduct

    DURING AN UNKNOWN ENDOSCOPIC PROCEDURE, THE PHYSICIAN USED A COOK ACUSNARE POLYPECTOMY SNARE SOFT. IT WAS REPORTED [THAT] SNARE [WAS] MELTING CLOSE TO HANDLE, SWITCHED CAUTERY MACHINE, AND SAME THING HAPPENED. A SECTION OF THE DEVICE DID NOT REMAIN INSIDE THE PATIENT¿S BODY. THE PATIENT DID NOT REQUIRE ANY ADDITIONAL PROCEDURES DUE TO THIS OCCURRENCE. ACCORDING TO THE INITIAL REPORTER, THE PATIENT DID NOT EXPERIENCE ANY ADVERSE EFFECTS DUE TO THIS OCCURRENCE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20127664 ↗
  • MalfunctionApr 8, 2024Material Twisted/Bent; Material Twisted/Bent

    DURING A COLONOSCOPY WITH POLYPECTOMY, THE PHYSICIAN USED A COOK ACUSNARE POLYPECTOMY SNARE, SOFT. IT WAS REPORTED THAT THE POLYP STALK WAS VERY HARD, AND THEY WERE UNABLE TO CUT THRU THE STALK. SEVERAL SNARES WERE USED AS THEY STATED THEY THOUGHT THE SNARE WAS MELTING THE PLASTIC SHEATH AT THE BASE OF THE HANDLE BUT IT WAS DETERMINED THAT IT WAS NOT MELTING BUT KINKING DUE TO THE TENSION PLACED ON THE HANDLE AND THE WIRE NOT CUTTING THRU THE POLYP STALK. THEY WERE ABLE TO SUCCESSFULLY REMOVE THE POLYP WITH ANOTHER OF THE SAME DEVICE. A SECTION OF THE DEVICE DID NOT REMAIN INSIDE THE PATIENT¿S BODY. THE PATIENT DID NOT REQUIRE ANY ADDITIONAL PROCEDURES DUE TO THIS OCCURRENCE. ACCORDING TO THE INITIAL REPORTER, THE PATIENT DID NOT EXPERIENCE ANY ADVERSE EFFECTS DUE TO THIS OCCURRENCE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19067359 ↗
  • MalfunctionFeb 20, 2023Material Deformation; Material Deformation

    DURING A COLONOSCOPY, THE PHYSICIAN USED A COOK ACUSNARE POLYPECTOMY SNARE SOFT. IT WAS REPORTED [THAT] WHILE THE SNARE WAS DOWN THE SCOPE, THEY HAD TROUBLE OPENING IT AND WHEN THEY PULLED IT OUT IT WAS TWISTED [SNARE HEAD WAS NOT ABLE TO RETRACT INTO THE CATHETER]. THE PHYSICIAN WAS NOT ABLE TO COMPLETE THE PROCEDURE WITH THIS DEVICE, SO THEY HAD TO OPEN A NEW ONE TO COMPLETE THE PROCEDURE WITH NO ISSUE. A SECTION OF THE DEVICE DID NOT REMAIN INSIDE THE PATIENT¿S BODY. THE PATIENT DID NOT REQUIRE ANY ADDITIONAL PROCEDURES DUE TO THIS OCCURRENCE. ACCORDING TO THE INITIAL REPORTER, THE PATIENT DID NOT EXPERIENCE ANY ADVERSE EFFECTS DUE TO THIS OCCURRENCE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16404172 ↗
  • MalfunctionFeb 26, 2021Material Frayed; Material Frayed

    DURING A COLONOSCOPY, THE PHYSICIAN USED A COOK ACUSNARE POLYPECTOMY SNARE. A POLYP WAS CAUTERIZED WITH JUST THE TIP OF THE SNARE. ONCE THE SNARE WAS REMOVED FROM THE ENDOSCOPE, IT WAS NOTED THAT THE WIRE WAS FRAYED. ANOTHER OF THE SAME DEVICE WAS USED TO COMPLETE THE PROCEDURE. OUR EVALUATION OF THE RETURNED DEVICE ON 4FEB2021 DETERMINED THE FAYED PORTION WAS A SHARP TIP AND WHEN RETRACTING, THE SNARE HAD RESISTANCE [SUBJECT OF REPORT]. A SECTION OF THE DEVICE DID NOT REMAIN INSIDE THE PATIENT¿S BODY. THE PATIENT DID NOT REQUIRE ANY ADDITIONAL PROCEDURES DUE TO THIS OCCURRENCE. ACCORDING TO THE INITIAL REPORTER, THE PATIENT DID NOT EXPERIENCE ANY ADVERSE EFFECTS DUE TO THIS OCCURRENCE.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 11387919 ↗
  • MalfunctionJan 15, 2021Failure to Conduct

    DURING A POLYPECTOMY PROCEDURE, THE PHYSICIAN USED A COOK ACUSNARE POLYPECTOMY SNARE. THE PHYSICIAN ADVANCED THE DEVICE TO THE DESIRED POSITION AND CAPTURE THE POLYP. THEN, ATTACHED THE ELECTROSURGICAL GENERATOR TO THE SNARE AND DISCOVERED THAT THERE WAS NO CURRENT. THE PHYSICIAN THEN CHANGED TO ANOTHER OF SAME DEVICE TO COMPLETE THE PROCEDURE. A SECTION OF THE DEVICE DID NOT REMAIN INSIDE THE PATIENTS BODY. THE PATIENT DID NOT REQUIRE ANY ADDITIONAL PROCEDURES DUE TO THIS OCCURRENCE. ACCORDING TO THE INITIAL REPORTER, THE PATIENT DID NOT EXPERIENCE ANY ADVERSE EFFECTS DUE TO THIS OCCURRENCE.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 11178069 ↗
  • MalfunctionJan 5, 2021Failure to Conduct; Failure to Conduct

    DURING A COLONOSCOPY, THE PHYSICIAN USED A COOK ACUSNARE POLYPECTOMY SNARE SOFT TO REMOVE A POLYP. IT WAS DISCOVERED THAT THE DEVICE HAD NO CURRENT. PHYSICIAN USED ANOTHER OF THE SAME DEVICE TO COMPLETE THE PROCEDURE. A SECTION OF THE DEVICE DID NOT REMAIN INSIDE THE PATIENT¿S BODY. THE PATIENT DID NOT REQUIRE ANY ADDITIONAL PROCEDURES DUE TO THIS OCCURRENCE. ACCORDING TO THE INITIAL REPORTER, THE PATIENT DID NOT EXPERIENCE ANY ADVERSE EFFECTS DUE TO THIS OCCURRENCE.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 11117876 ↗
  • MalfunctionDec 22, 2020Deformation Due to Compressive Stress; Deformation Due to Compressive Stress

    IN PREPARATION FOR AN ENDOSCOPIC POLYPECTOMY, THE PHYSICIAN USED A COOK ACUSNARE POLYPECTOMY SNARE AND INTENDED TO REMOVE A LOWER ESOPHAGEAL POLYP. THE PHYSICIAN OPENED THE PACKAGE AND CHECKED THE DEVICES INTEGRITY BEFORE USING IT, AND DISCOVERED THAT THE WIRE AT THE HANDLE WAS KINKED, WHICH PREVENTED THE HANDLE FROM PULLING PROPERLY [DIFFICULTY WITH RETRACTION]. THE DEVICE WAS NOT USED ON PATIENT. THE PHYSICIAN THEN CHANGED TO ANOTHER OF THE SAME DEVICE IMMEDIATELY TO COMPLETE THE PROCEDURE. THIS OCCURRED PRIOR TO PATIENT CONTACT; THERE WAS NO IMPACT TO THE PATIENT.

    Patient problems: No Patient Involvement

    MAUDE report 11060401 ↗
  • MalfunctionOct 20, 2020Deformation Due to Compressive Stress; Deformation Due to Compressive Stress

    DURING A COLONOSCOPY, THE PHYSICIAN USED AN ACUSNARE POLYPECTOMY SNARE SOFT. WHEN THE POLYPECTOMY SNARE OPENED AND WAS PLACED AROUND THE POLYP, THE CUTTING WIRE EXPOSED PORTION IN THE HANDLE BENT WHICH KEPT THE PHYSICIAN FROM CUTTING THE POLYP [SUBJECT OF REPORT]. ANOTHER OF THE SAME DEVICES AND LOT NUMBER WAS USED TO COMPLETE THE PROCEDURE WITH NO FURTHER COMPLICATIONS. A SECTION OF THE DEVICE DID NOT REMAIN INSIDE THE PATIENT¿S BODY. THE PATIENT DID NOT REQUIRE ANY ADDITIONAL PROCEDURES DUE TO THIS OCCURRENCE. ACCORDING TO THE INITIAL REPORTER, THE PATIENT DID NOT EXPERIENCE ANY ADVERSE EFFECTS DUE TO THIS OCCURRENCE.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10706492 ↗
  • MalfunctionOct 20, 2020Deformation Due to Compressive Stress; Deformation Due to Compressive Stress

    DURING A COLONOSCOPY, THE PHYSICIAN USED AN ACUSNARE POLYPECTOMY SNARE SOFT. WHEN THE POLYPECTOMY SNARE OPENED AND WAS PLACED AROUND THE POLYP, THE CUTTING WIRE EXPOSED PORTION IN THE HANDLE BENT WHICH KEPT THE PHYSICIAN FROM CUTTING THE POLYP [SUBJECT OF REPORT]. ANOTHER ONE OF THE SAME DEVICES AND LOT NUMBER WAS USED TO COMPLETE THE PROCEDURE WITH NO FURTHER COMPLICATIONS. A SECTION OF THE DEVICE DID NOT REMAIN INSIDE THE PATIENT¿S BODY. THE PATIENT DID NOT REQUIRE ANY ADDITIONAL PROCEDURES DUE TO THIS OCCURRENCE. ACCORDING TO THE INITIAL REPORTER, THE PATIENT DID NOT EXPERIENCE ANY ADVERSE EFFECTS DUE TO THIS OCCURRENCE.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10705593 ↗
  • MalfunctionOct 20, 2020Deformation Due to Compressive Stress; Deformation Due to Compressive Stress

    DURING A COLONOSCOPY, THE PHYSICIAN USED AN ACUSNARE POLYPECTOMY SNARE SOFT. WHEN THE POLYPECTOMY SNARE OPENED AND WAS PLACED AROUND THE POLYP THE CUTTING WIRE, EXPOSED PORTION IN THE HANDLE, BENT WHICH KEPT THE PHYSICIAN FROM CUTTING THE POLYP [SUBJECT OF REPORT]. ANOTHER OF THE SAME DEVICE AND LOT NUMBER WAS USED TO COMPLETE THE PROCEDURE WITH NO FURTHER COMPLICATIONS. A SECTION OF THE DEVICE DID NOT REMAIN INSIDE THE PATIENT¿S BODY. THE PATIENT DID NOT REQUIRE ANY ADDITIONAL PROCEDURES DUE TO THIS OCCURRENCE. ACCORDING TO THE INITIAL REPORTER, THE PATIENT DID NOT EXPERIENCE ANY ADVERSE EFFECTS DUE TO THIS OCCURRENCE.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10704799 ↗
  • MalfunctionOct 8, 2020Fracture; Retraction Problem; Material Separation; Fracture; Retraction Problem; Material Separation

    DURING AN ENDOSCOPIC PROCEDURE TO REMOVE AN INTESTINAL POLYP, THE PHYSICIAN USED AN ACUSNARE POLYPECTOMY SNARE SOFT. THE USER ADVANCED THE DEVICE TO THE DESIRED POSITION AND TRIED TO REMOVE THE POLYP AND FOUND OUT THAT THE WIRE AT THE HANDLE WAS BROKEN. THE USER RETRACTED THE DEVICE [FROM THE ENDOSCOPE] AND CHANGED TO ANOTHER ONE OF THE SAME DEVICES TO COMPLETE THE PROCEDURE. DUE TO THE HANDLE CANNULA BREAKING AND THE SNARE HEAD BEING ADVANCED, IT WAS REASONABLE TO CONCLUDE THE DEVICE WOULD NOT RETRACT [SUBJECT OF REPORT]. ADDITIONAL INFORMATION WAS PROVIDED ON 24-SEPTEMBER-2020 WHICH CONFIRMED THE INABILITY OR DIFFICULTY TO RETRACT THE SNARE ONCE ADVANCED OUT OF THE SHEATH. THE USER PULLED THE HANDLE WITH NO RESPONSE FROM SNARE. A SECTION OF THE DEVICE DID NOT REMAIN INSIDE THE PATIENT¿S BODY. THE PATIENT DID NOT REQUIRE ANY ADDITIONAL PROCEDURES DUE TO THIS OCCURRENCE. ACCORDING TO THE INITIAL REPORTER, THE PATIENT DID NOT EXPERIENCE ANY ADVERSE EFFECTS DUE TO THIS OCCURRENCE.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10649546 ↗
  • MalfunctionJun 20, 2019Break; Retraction Problem; Sharp Edges; Break; Retraction Problem; Sharp Edges

    DURING A COLONIC POLYPECTOMY PROCEDURE, THE PHYSICIAN USED A COOK ACUSNARE POLYPECTOMY SNARE. DURING CAUTERIZATION, THE SNARE WIRE "SNAPPED". NO PORTION OF THE WIRE DETACHED. IT BROKE, BUT REMAINED INTACT. THERE WAS NO REPORTABLE INFORMATION AT THAT TIME. THE DEVICE WAS EVALUATED ON (B)(6) 2019 AND IT WAS DETERMINED THAT THE BROKEN PORTION OF THE SNARE WIRE WAS SHARP. THERE WAS ALSO RESISTANCE IN RETRACTION. NO PORTION OF THE DEVICE IS MISSING. A SECTION OF THE DEVICE DID NOT REMAIN INSIDE THE PATIENT¿S BODY. THE PATIENT DID NOT REQUIRE ANY ADDITIONAL PROCEDURES DUE TO THIS OCCURRENCE. ACCORDING TO THE INITIAL REPORTER, THE PATIENT DID NOT EXPERIENCE ANY ADVERSE EFFECTS DUE TO THIS OCCURRENCE.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8716999 ↗
  • MalfunctionJan 26, 2018Failure to Conduct; Failure to Conduct

    DURING AN ENDOSCOPIC PROCEDURE, THE PHYSICIAN USED A COOK ACUSNARE POLYPECTOMY SNARE SOFT. THE SNARE CAUTERY DID NOT WORK PROPERLY. ADDITIONAL INFORMATION WAS RECEIVED ON 01/11/2018: THE DEVICE DID NOT ALLOW ANY TRANSFER OF ELECTRICAL POWER.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 7221387 ↗
  • MalfunctionSep 27, 2017Failure to Conduct; Failure to Conduct

    DURING AN ENDOSCOPIC PROCEDURE, THE PHYSICIAN USED A COOK ACUSNARE POLYPECTOMY SNARE SOFT. WHEN THEY TRIED TO ATTACH THE ACTIVE CORD AND USE THE DEVICES HOT SNARING, THE DEVICES WOULD NOT WORK FOR HOT SNARING [SEE RELATED MDR 1037905-2017-00610]. THEY REPLACED THE ACTIVE CORD AND TRIED AGAIN BUT THE DEVICES WOULD STILL NOT WORK [SUBJECT OF THIS REPORT]. ADDITIONAL INFORMATION WAS PROVIDED ON 09/12/2017 THAT CLARIFIED THAT THE SNARE DID NOT ALLOW CONSISTENT TRANSFER OF ELECTRICAL POWER AND ALLOWED COAGULATION/BURNING BUT DID NOT CUT PROPERLY.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 6896866 ↗
  • MalfunctionSep 27, 2017Failure to Conduct; Failure to Conduct

    DURING AN ENDOSCOPIC PROCEDURE, THE PHYSICIAN USED A COOK ACUSNARE POLYPECTOMY SNARE SOFT. WHEN THEY TRIED TO ATTACH THE ACTIVE CORD AND USE THE DEVICES FOR HOT SNARING, THE DEVICES WOULD NOT WORK FOR HOT SNARING [SUBJECT OF THIS REPORT]. THEY REPLACED THE ACTIVE CORD AND TRIED AGAIN BUT THE DEVICES WOULD STILL NOT WORK [SEE RELATED MDR 1037905-2017-00611]. ADDITIONAL INFORMATION WAS PROVIDED ON 09/12/2017 THAT CLARIFIED THAT THE SNARE DID NOT ALLOW CONSISTENT TRANSFER OF ELECTRICAL POWER AND ALLOWED COAGULATION/BURNING BUT DID NOT CUT PROPERLY.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 6896864 ↗

Other Unit, electrosurgical, endoscopic (with or without accessories) devices

All Unit, electrosurgical, endoscopic (with or without accessories) devices →