SureTome SW G61351Recalls & reported problems

Cook Incorporated · SureTome SW Sphincterotome with DomeTip · Class 2

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00827002613515), received between Mar 17, 2026 and Sep 9, 2026 — classified as 1 injury, 2 malfunctions.

The most frequently reported specific device problem is “Material Separation” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 1 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 1 reportsSep 2026: 1 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1
  • Material Separation1
  • Sharp Edges1

Patient problems

  • No Clinical Signs, Symptoms or Conditions2
  • Perforation1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 9, 2026Material Separation

    During an endoscopic retrograde cholangiopancreatography (ERCP) procedure, the physician used a Cook SureTome SW Sphincterotome. It was reported that the tip of the tome was split. The doctor replaced it with a new tome. The rep is in-servicing the use of this device to ensure they did not strip it all the way to the tip of the tome.A section of the device did not remain inside the patient¿s body. The patient did not require any additional procedures due to this occurrence. According to the initial reporter, the patient did not experience any adverse effects due to this occurrence.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50695660 ↗
  • InjuryAug 7, 2026Adverse Event Without Identified Device or Use Problem

    During an endoscopic retrograde cholangiopancreatography (ERCP) procedure, the physician used a Cook SureTome SW Sphincterotome. It was reported that during cannulation, a perforation of the common bile duct occurred.Patient case records confirmed that the same physician had attempted an ERCP on the same patient the prior Monday, had significant difficulty cannulating, used a needle knife multiple times, cut into the papilla for access, and was ultimately unsuccessful. The case under investigation was therefore a redo attempt. The ERCP was performed for suspected choledocholithiasis, though no stones were confirmed. The physician described a straightforward case: cannulation on the first attempt, the wire guide advancing cleanly into position in the common bile duct, contrast injection with no bowing, no rotation of the tome, and no cut performed. As he advanced the tome further into the duct with contrast still being injected, he observed bile leaking low in the common bile duct near the papilla, immediately withdrew the tome and wire guide, and aborted the procedure. He and the staff noted no defects in the device. Imaging he provided was inconclusive ¿ the fluoroscopic images di

    Patient problems: Perforation

    MAUDE report 50178191 ↗
  • MalfunctionMar 17, 2026Sharp Edges

    DURING AN ENDOSCOPIC RETROGRADE CHOLANGIOPANCREATOGRAPHY (ERCP) PROCEDURE, THE PHYSICIAN USED A COOK SURETOME SW SPHINCTEROTOME. IT WAS REPORTED THAT THE TIP OF THE TOME BROKE AND DETACHED. UPON INVESTIGATION OF THE RETURNED COMPLAINT DEVICE, IT WAS FOUND THAT IT WAS THE TIP OF THE CATHETER THAT HAS BEEN DAMAGED WHILE THE CUTTING WIRE REMAINS INTACT. IT DOES NOT APPEAR THAT ANY PORTION OF THE CATHETER MATERIAL HAS DETACHED, BUT THAT THE PEELED BACK PORTION/GAP AT THE DISTAL TIP LED TO AN APPEARANCE OF A SEGMENT MISSING AT FIRST GLANCE. A SECTION OF THE DEVICE DID NOT REMAIN INSIDE THE PATIENT¿S BODY. THE PATIENT DID NOT REQUIRE ANY ADDITIONAL PROCEDURES DUE TO THIS OCCURRENCE. ACCORDING TO THE INITIAL REPORTER, THE PATIENT DID NOT EXPERIENCE ANY ADVERSE EFFECTS DUE TO THIS OCCURRENCE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24621762 ↗

Other Unit, electrosurgical, endoscopic (with or without accessories) devices