NA Discovery MR750w 3.0TRecalls & reported problems
GE Medical Systems, L.L.C. · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
4 open recalls name this device. See the recall details and contact the manufacturer or your healthcare provider.
- Adverse event reports
- 0
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 13
Summary
No MAUDE adverse event reports in our data reference this device identifier directly.
13 FDA recall records name this device's identifier, 4 still open.
22 other recalls cover devices cleared under the same FDA submission (K142085); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Recalls naming this device
- Jun 20, 2025Class IIOpen, Classified
GE HealthCare has become aware that for certain MR systems (SIGNA Artist, SIGNA Voyager, Discovery MR450 1.5T, Optima MR450w 1.5T, SIGNA Architect, SIGNA Premier, SIGNA UHP, Discovery MR750 3.0T, Discovery MR750w 3.0T, SIGNA Hero, SIGNA PET/MR, SIGNA Artist Evo, SIGNA Voyager AIR (China Only), SIGNA Architect AIR (China Only), SIGNA Premier XT (China Only), SIGNA Premier Elite (China Only), SIGNA Premier MAX (China Only), SIGNA Hero XT (China Only), SIGNA Hero Elite (China Only), SIGNA Hero MAX (China Only), SIGNA PET/MR AIR (China Only), SIGNA PET/MR AIR Plus (China Only), the planned maintenance steps to check the functionality of the caster locks on the MR patient table may not have been performed.
Z-2307-2025 · Root cause: Equipment maintenance · Recall details · FDA record ↗
- Jun 20, 2025Class IIOpen, Classified
GE HealthCare has become aware that for certain MR systems (SIGNA Artist, SIGNA Voyager, Discovery MR450 1.5T, Optima MR450w 1.5T, SIGNA Architect, SIGNA Premier, SIGNA UHP, Discovery MR750 3.0T, Discovery MR750w 3.0T, SIGNA Hero, SIGNA PET/MR, SIGNA Artist Evo, SIGNA Voyager AIR (China Only), SIGNA Architect AIR (China Only), SIGNA Premier XT (China Only), SIGNA Premier Elite (China Only), SIGNA Premier MAX (China Only), SIGNA Hero XT (China Only), SIGNA Hero Elite (China Only), SIGNA Hero MAX (China Only), SIGNA PET/MR AIR (China Only), SIGNA PET/MR AIR Plus (China Only), the planned maintenance steps to check the functionality of the caster locks on the MR patient table may not have been performed.
Z-2303-2025 · Root cause: Equipment maintenance · Recall details · FDA record ↗
- May 23, 2025Class IIOpen, Classified
GE HealthCare has become aware that gradient coils for certain MR systems (see affected product list in this letter), under specific conditions, can produce elevated acoustic noise during scanning. As a result, acoustic levels can exceed 99dB, the limit established by International Electrotechnical Commission (IEC 60601-2-33) when using hearing protection with a Noise Reduction Rating (NRR) of 29dB, as currently required in the Operator Manual.
Z-2132-2025 · Root cause: Device Design · Recall details · FDA record ↗
- Oct 28, 2024Class IIOpen, Classified
Gradient coils for certain MR systems (see affected product list in this letter), under specific conditions, can produce elevated acoustic noise during scanning.
Z-0517-2025 · Root cause: Device Design · Recall details · FDA record ↗
- May 11, 2017Class IITerminated
Possible incorrect wiring of the Uninterruptable Power Supply, which could contribute to a potential shock hazard.
Z-3027-2017 · Root cause: Mixed-up of materials/components · Recall details · FDA record ↗
- May 11, 2017Class IITerminated
Possible incorrect wiring of the Uninterruptable Power Supply, which could contribute to a potential shock hazard.
Z-3022-2017 · Root cause: Mixed-up of materials/components · Recall details · FDA record ↗
- May 11, 2017Class IITerminated
Possible incorrect wiring of the Uninterruptable Power Supply, which could contribute to a potential shock hazard.
Z-3023-2017 · Root cause: Mixed-up of materials/components · Recall details · FDA record ↗
- May 11, 2017Class IITerminated
Possible incorrect wiring of the Uninterruptable Power Supply, which could contribute to a potential shock hazard.
Z-3025-2017 · Root cause: Mixed-up of materials/components · Recall details · FDA record ↗
- May 11, 2017Class IITerminated
Possible incorrect wiring of the Uninterruptable Power Supply, which could contribute to a potential shock hazard.
Z-3028-2017 · Root cause: Mixed-up of materials/components · Recall details · FDA record ↗
- May 11, 2017Class IITerminated
Possible incorrect wiring of the Uninterruptable Power Supply, which could contribute to a potential shock hazard.
Z-3026-2017 · Root cause: Mixed-up of materials/components · Recall details · FDA record ↗
- May 11, 2017Class IITerminated
Possible incorrect wiring of the Uninterruptable Power Supply, which could contribute to a potential shock hazard.
Z-3024-2017 · Root cause: Mixed-up of materials/components · Recall details · FDA record ↗
- May 11, 2017Class IITerminated
Possible incorrect wiring of the Uninterruptable Power Supply, which could contribute to a potential shock hazard.
Z-3029-2017 · Root cause: Mixed-up of materials/components · Recall details · FDA record ↗
- May 11, 2017Class IITerminated
Possible incorrect wiring of the Uninterruptable Power Supply, which could contribute to a potential shock hazard.
Z-3021-2017 · Root cause: Mixed-up of materials/components · Recall details · FDA record ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K142085. One submission often covers many models, so check the product and lot details in each record.
- Z-2301-2025 · Jun 20, 2025 · Open, ClassifiedGE Discovery MR450 1.5T, Nuclear Magnetic Resonance Imaging System
- Z-2306-2025 · Jun 20, 2025 · Open, ClassifiedGE Discovery MR750 3.0T, Nuclear Magnetic Resonance Imaging System
- Z-2302-2025 · Jun 20, 2025 · Open, ClassifiedGE Optima MR450w 1.5T, Nuclear Magnetic Resonance Imaging System
- Z-2465-2024 · Jun 14, 2024 · Open, ClassifiedDiscovery MR750w 3.0T, with affected software versions: DV24.0, DV25.0, DV25.1, DV26.0 to DV26.5, DV29.1, MR30.0, MR30.1; Nuclear Magnetic Resonance Imaging System
- Z-2467-2024 · Jun 14, 2024 · Open, ClassifiedDiscovery MR450 1.5T, with affected software versions: DV24.0, DV25.0, DV25.1, DV26.0; Nuclear Magnetic Resonance Imaging System
- Z-2468-2024 · Jun 14, 2024 · Open, ClassifiedOptima MR450w 1.5T, with affected software versions: DV24.0, DV25.0, DV25.1, DV26.0, DV29.1, MR30.0, MR30.1; Nuclear Magnetic Resonance Imaging System
- Z-2464-2024 · Jun 14, 2024 · Open, ClassifiedDiscovery MR750 3.0T, with affected software versions: DV24.0, DV25.0, DV25.1, DV26.0 to DV26.4, DV29.1, MR30.0, MR30.1; Nuclear Magnetic Resonance Imaging System
- Z-0594-2022 · Dec 23, 2021 · Open, ClassifiedGE Healthcare MR superconducting magnets, a component of GE Healthcare Discovery MR750 3.0T System, nuclear magnetic resonance imaging system.
- Z-0593-2022 · Dec 23, 2021 · Open, ClassifiedGE Healthcare MR superconducting magnets, a component of GE Healthcare Discovery MR750w 3.0T System, nuclear magnetic resonance imaging system.
- Z-0602-2022 · Dec 23, 2021 · Open, ClassifiedGE Healthcare MR superconducting magnets, a component of GE Healthcare Discovery MR450 1.5T system, nuclear magnetic resonance imaging system.
- Z-0601-2022 · Dec 23, 2021 · Open, ClassifiedGE Healthcare MR superconducting magnets, a component of GE Healthcare Optima MR450w 1.5T, Optima MR450w GEM system, nuclear magnetic resonance imaging system.
- Z-0140-2022 · Aug 26, 2021 · TerminatedOptima MR450w 1.5T nuclear magnetic resonance imaging system
- Z-0136-2022 · Aug 26, 2021 · TerminatedDiscovery MR750 3.0T nuclear magnetic resonance imaging system
- Z-0135-2022 · Aug 26, 2021 · TerminatedDiscovery MR750w 3.0T nuclear magnetic resonance imaging system
- Z-2064-2021 · Jun 4, 2021 · Open, ClassifiedDiscovery MR450 1.5T, Nuclear Magnetic Resonance Imaging System
…and 7 more.
Other System, nuclear magnetic resonance imaging devices
- Ingenia Ingenia Elition XPhilips Medical Systems Nederland B.V. · System, nuclear magnetic resonance imaging14 recalls12 reports
- Ingenia Elition SPhilips Medical Systems Nederland B.V. · System, nuclear magnetic resonance imaging13 recalls2 reports
- Ingenia Ingenia Ambition XPhilips Medical Systems Nederland B.V. · System, nuclear magnetic resonance imaging12 recalls12 reports
- Ingenia Ingenia 3.0T CXPhilips Medical Systems Nederland B.V. · System, nuclear magnetic resonance imaging11 recalls59 reports
- Ingenia Smartpath to dStream for 3.0TPhilips Medical Systems Nederland B.V. · System, nuclear magnetic resonance imaging11 recalls44 reports
- Ingenia Ingenia Elition XPhilips Medical Systems Nederland B.V. · System, nuclear magnetic resonance imaging11 recalls5 reports
- MR 7000 Series MR 7700Philips Medical Systems Nederland B.V. · System, nuclear magnetic resonance imaging11 recalls4 reports
- Ingenia Ingenia Elition SPhilips Medical Systems Nederland B.V. · System, nuclear magnetic resonance imaging11 recalls3 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026 · each recall links to the FDA recall notice
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page