Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00852454006028), received between Nov 26, 2018 and Nov 26, 2018 — classified as 1 injury.
The most frequently reported specific device problem is “Improper or Incorrect Procedure or Method” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Improper or Incorrect Procedure or Method1
Patient problems
- Hematoma1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryNov 26, 2018Improper or Incorrect Procedure or Method; Improper or Incorrect Procedure or Method
THE PHYSICIAN HAD SUCCESSFULLY COMPLETED CADAVER TRAINING AND WAS WELL VERSED IN TRANS-PEDICULAR ACCESS, HAVING PERFORMED MANY KYPHOPLASTY PROCEDURES AND INSTRUMENTED FUSION SURGERIES. DURING THE CASE, THE PHYSICIAN APPROACHED THE LEFT L5 PEDICLE WITH THE INTRACEPT INTRODUCER USING AN OBLIQUE EN FACE VIEW UNDER C-ARM FLUOROSCOPIC GUIDANCE. A LATERAL FLUOROSCOPIC IMAGE ESTABLISHED THAT THE TIP OF THE INTRODUCER WAS VENTRAL TO THE SPINOUS PROCESS, AND THE SURGEON REMOVED THE INTRODUCER. HE RE-INITIATED THE PROCEDURE USING A 22-GAUGE SPINAL NEEDLE AS A GUIDE. THE REMAINDER OF THE PROCEDURE WENT WITHOUT INCIDENT, AND THE BASIVERTEBRAL NERVES WERE SUCCESSFULLY ABLATED ON THE LEFT AT L5 AND THE RIGHT AT L4. THERE WERE NO INTRA-OPERATIVE OR IMMEDIATE POST-OPERATIVE SIGNS OR SYMPTOMS OF COMPLICATION NOTED. THE SURGEON CONTACTED THE TERRITORY MANAGER STATING THAT THE PATIENT WAS TAKEN TO THE HOSPITAL WITH A RETROPERITONEAL HEMATOMA. PT WAS TRANSFERRED 4 1/2 HRS POST OP WITH HYPOTENSION TO LOCAL TRAUMA HOSPITAL. GOT 5 UNITS. ANGIO WAS NEGATIVE AND GOT SOME "ILIOLUMBARS" COILS TO BE SAFE. WENT HOME (B)(6) 2018. ONLY PAIN SHE HAD ON THAT DAY WAS BY THE LLQ WHERE THE HEMATOMA WAS. NO REPORTED B
Patient problems: Hematoma
MAUDE report 8102634 ↗
Other Probe, Radiofrequency Lesion devices
- NA TCN-15Boston Scientific Neuromodulation Corporation · PROBE, RADIOFREQUENCY LESION2 recalls10 reports
- NA TCN-10-3MBoston Scientific Neuromodulation Corporation · PROBE, RADIOFREQUENCY LESION2 recalls9 reports
- NA CSK-TC10Boston Scientific Neuromodulation Corporation · PROBE, RADIOFREQUENCY LESION1 recall1 death58 reports
- NA CLASSICSt. Jude Medical, Inc. · PROBE, RADIOFREQUENCY LESION1 recall40 reports
- Intracept RLV 0055Relievant Medsystems, Inc. · Probe, Radiofrequency Lesion1 recall30 reports
- Intracept RLV 0045Relievant Medsystems, Inc. · Probe, Radiofrequency Lesion1 recall1 death23 reports
- Intracept RLV0065Relievant Medsystems, Inc. · Probe, Radiofrequency Lesion1 recall14 reports
- NA CSK-TC5Boston Scientific Neuromodulation Corporation · PROBE, RADIOFREQUENCY LESION1 recall3 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page