MicroMax Low Flow DISSRecalls & reported problems
Maxtec, LLC · MicroMax Low Flow Air/Oxygen Blender with DISS Fitting · Class 2
Data updated Oct 13, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00853061006074), received between Dec 20, 2019 and Nov 17, 2020 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Fire” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Fire2
Patient problems
- Superficial (First Degree) Burn2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionNov 17, 2020Fire; Fire
DESCRIPTION OF THE EVENT AS GIVEN TO MAXTEC VIA CUSTOMER COMPLAINT. "ON 26TH NOV, OUR VENDOR WAS IN NICU DEPT FOR INSTALLATION OF BUBBLE CPAP WITH MAXTECH MAX BLENDER, AFTER INSTALLATION , VENDOR WAS HAVING FINAL CHECKING OR TRIAL OF PROPER FUNCTIONING OF CPAP DEVICE, WITH A FLOW OF 10 LITRE. SUDDENLY THE BLENDER GOT BURST WITH FIRE...THERE WAS NO INJURY TO HOSPITAL STAFF OR PATIENT... OUR CHANNEL PARTNER (MR. (B)(6) MET WITH A SUPERFICIAL BURN OF HIS LEFT HAND AND HE GOT IMMEDIATELY FIRST AID TREATMENT FROM THE HOSPITAL." THE CUSTOMER PROVIDED ADDITIONAL DETAILS REGARDING THE EVENT VIA REPORT PS: (B)(4) STATING THE FOLLOWING: "WHILE INSTALLING THE BUBBLE CPAP SET UP AND UPON CONNECTING THE BLENDER, THE DEALER SWITCHED ON THE COMPRESSOR AND THE HOSPITAL WARD BOY OPENED THE O2 CYLINDER. WITHIN NO TIME, THE BLENDER STARTED ALARMING CONTINUOUSLY AND FIRE WAS OBSERVED AT THE TOP AND BOTTOM OF THE BLENDER. IMMEDIATELY, THE DEALER DISCONNECTED ALL CONNECTIONS TURNING THE O2 CYLINDER OFF. DURING THIS PROCEDURE, THE DEALER WAS LEFT WITH A MINOR BURN ON HIS SHOULDER."
Patient problems: Superficial (First Degree) Burn
MAUDE report 10857079 ↗MalfunctionDec 20, 2019Fire; Fire
MAXTEC (PRIVATE LABEL DISTRIBUTOR) RECEIVED THE INFORMATION BELOW FROM THEIR CUSTOMER F&P IN INDIA. INFORMATION FORMALLY PROVIDED: ON 26TH NOV, OUR VENDOR WAS IN NICU DEPT FOR INSTALLATION OF BUBBLECPAP WITH MAXTEC BLENDER, AFTER INSTALLATION, VENDOR WAS HAVING FINAL CHECKING OR TRIAL OF PROPER FUNCTIONING OF CPAP DEVICE, WITH A FLOW OF 10 LITER. SUDDENLY THE BLENDER GOT BURST OF FIRE.... THERE WAS NO INJURY TO HOSPITAL STAFF, PATIENTS...OUR CHANNEL PARTNER MET WITH A SUPERFICAIAL BURN OF HIS LEFT HAND AND GOT IMMEDITALEY FIRST AID TREATMENT FROM THE HOSPITAL ADDTIONALLY INFORMATION YET TO BE VERIFIED INDICATES A SLIGHTLY DIFFERENT SEQUENCE OF EVENTS. ALSO, FAILURE (REGULATOR - NOT SUPPLIED BY PRECISION MEDICAL INC) OF ADDITIONAL EQUIPMENT IN THE GAS SUPPLY CIRCUIT. NEITHER CHANGING THE END RESULTS.
Patient problems: Superficial (First Degree) Burn
MAUDE report 9505546 ↗
Other Mixer, Breathing Gases, Anesthesia Inhalation devices
- Blender 03800ACarefusion Corporation · Mixer, Breathing Gases, Anesthesia Inhalation1 death23 reports
- Bird Blender 03920ACarefusion Corporation · Mixer, Breathing Gases, Anesthesia Inhalation17 reports
- Sechrist Industries, Inc. 3500CP-GSechrist Industries, Inc. · Mixer, Breathing Gases, Anesthesia Inhalation1 death11 reports
- Hyperinflation AMBU 900 000 614Westmed, Inc. · Mixer, Breathing Gases, Anesthesia Inhalation6 reports
- Blender 10040ACarefusion Corporation · Mixer, Breathing Gases, Anesthesia Inhalation4 reports
- Sechrist Industries, Inc. 3500CP-G24Sechrist Industries, Inc. · Mixer, Breathing Gases, Anesthesia Inhalation4 reports
- Precision Medical Blender PM5300Precision Medical, Inc. · Mixer, Breathing Gases, Anesthesia Inhalation3 reports
- Sechrist Industries, Inc. 3500CP-G4Sechrist Industries, Inc. · Mixer, Breathing Gases, Anesthesia Inhalation3 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page