Lithotripsy System ShockPulse-SE SPL-SRecalls & reported problems

Cybersonics Inc · Class 2

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
7
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 7 adverse event reports that list this exact device (DI 00855279005016), received between Jan 8, 2021 and Sep 16, 2024 — classified as 1 injury, 6 malfunctions.

The most frequently reported specific device problem is “Communication or Transmission Problem” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 1 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 1 reportsSep 2024: 1 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1
  • Communication or Transmission Problem1
  • Defective Component1
  • Defective Device1
  • Failure to Power Up1
  • Power Problem1
  • Unable to Obtain Readings1

Patient problems

  • No Clinical Signs, Symptoms or Conditions6
  • No Patient Involvement2

Recent adverse event reports

The 7 most recent of 7 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 16, 2024Unable to Obtain Readings; Unable to Obtain Readings

    IT WAS REPORTED THE SUBJECT DEVICE STOPPED READING ALL TRANSDUCERS, MAKING IT INOPERABLE. THERE WAS NO REPORT OF PATIENT HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20230458 ↗
  • MalfunctionAug 9, 2024Communication or Transmission Problem; Communication or Transmission Problem

    IT WAS REPORTED DURING AN UNSPECIFIED PROCEDURE, THE SUBJECT DEVICE HAD ERRORS THAT WERE COMING UP WHEN THE HAND PIECES WERE ACTIVATED. THERE WERE NO REPORTS OF PATIENT HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19951977 ↗
  • MalfunctionDec 1, 2023Power Problem; Power Problem

    A USER FACILITY RETURNED THE OLYMPUS ASSET, SHOCKPULSE-SE LITHOTRIPSY SYSTEM, TO THE OLYMPUS SERVICE CENTER. UPON INSPECTION AND TESTING OF THE RETURNED DEVICE, IT WAS OBSERVED THAT THE DEVICE HAD NO POWER. THIS REPORT IS BEING SUBMITTED FOR THE REPORTABLE MALFUNCTION FOUND DURING EVALUATION. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18245755 ↗
  • InjuryAug 3, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    THE NURSE REPORTED TO OLYMPUS THAT DURING AN UNKNOWN PROCEDURE, WHEN USING SHOCKPULSE-SE LITHOTRIPSY SYSTEM A VISIBLE DAMAGE TO THE CONNECTOR PIN WAS DETECTED AND AN ERROR MESSAGE WAS PRODUCED ON THE SCOPE. THE TRANSDUCER RECEPTACLE WAS REPLACED AS DAMAGED PIN WAS FOUND INSIDE THE CONNECTOR CAUSING A PROCEDURAL DELAY OF 45 MINUTES AND PATIENT ADDITIONALLY SEDATED. THE PROCEDURE WAS COMPLETED WITH A SIMILAR VENDOR DEVICE AND NO MEDICAL INTERVENTION WAS UNDERTAKEN. NO HEALTH HAZARDS REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17452690 ↗
  • MalfunctionJul 21, 2023Failure to Power Up; Failure to Power Up

    THE SHOCKPULSE-SE LITHOTRIPSY SYSTEM WAS RETURNED AS PART OF THE ASSET RETURN PROCESS. DURING ROUTINE INSPECTION OF THE DEVICE BY OLYMPUS, A DEFECTIVE POWER SUPPLY WAS FOUND. THERE WAS NO PROCEDURAL OR PATIENT INVOLVEMENT ASSOCIATED WITH THIS EVENT. THIS MDR IS BEING SUBMITTED TO CAPTURE THE REPORTABLE MALFUNCTION FOUND DURING THE DEVICE EVALUATION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17368709 ↗
  • MalfunctionJan 13, 2021Defective Device; Defective Device

    IT WAS REPORTED THAT DURING PREPARATION FOR USE THE DEVICE WAS FOUND WITH DAMAGED TRANSDUCER RECEPTACLE. THE TRANSDUCER WAS NOT RECOGNIZED BY THE GENERATOR. NO PATIENT INVOLVEMENT ON THIS EVENT REPORTED. NO USER INJURY REPORTED.

    Patient problems: No Patient Involvement

    MAUDE report 11163682 ↗
  • MalfunctionJan 8, 2021Defective Component; Defective Component

    IT WAS REPORTED THAT DURING AN ASSET RETURN INSPECTION THE DEVICE WAS FOUND WITH A BROKEN POWER BOARD. NO PATIENT INVOLVEMENT ON THIS EVENT. NO USER INJURY REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions; No Patient Involvement

    MAUDE report 11143019 ↗

Other Lithotriptor, Ultrasonic devices