Intuitive Surgical, Inc. · SURGEON SIDE CONSOLE, RECONDITIONED · Class 2

All models of da Vinci Surgical System (9) · da Vinci Xi (2)

Data updated Nov 27, 2026 from official FDA records · Editorial policy

1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.

Quick summary

This Intuitive da Vinci Xi surgeon console has 176 adverse event reports, with no deaths and 14 injuries. The reports mostly describe error messages during setup, blank or black displays, and systems failing to power up, with some procedures moved to a second console. One recall is open, started in September 2022, over unintended energy delivered from certain bipolar instruments in specific setups.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
175
Deaths reported
0
Injuries reported
14
Recalls naming it
1

Summary

The FDA's MAUDE database contains 175 adverse event reports that list this exact device (DI 00886874115374), received between Jun 3, 2020 and Sep 25, 2026 — classified as 14 injuries, 161 malfunctions.

The most frequently reported specific device problem is “Visual Prompts will not Clear” (52 reports).

1 FDA recall record name this device's identifier, 1 still open.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Reports received per month

Dec 2023: 2 reportsJan 2024: 3 reportsFeb 2024: 0 reportsMar 2024: 4 reportsApr 2024: 0 reportsMay 2024: 1 reportsJun 2024: 2 reportsJul 2024: 1 reportsAug 2024: 1 reportsSep 2024: 6 reportsOct 2024: 1 reportsNov 2024: 8 reportsDec 2024: 2 reportsJan 2025: 2 reportsFeb 2025: 2 reportsMar 2025: 3 reportsApr 2025: 4 reportsMay 2025: 2 reportsJun 2025: 3 reportsJul 2025: 3 reportsAug 2025: 3 reportsSep 2025: 1 reportsOct 2025: 3 reportsNov 2025: 3 reportsDec 2025: 0 reportsJan 2026: 4 reportsFeb 2026: 2 reportsMar 2026: 18 reportsApr 2026: 10 reportsMay 2026: 4 reportsJun 2026: 0 reportsJul 2026: 2 reportsAug 2026: 7 reportsSep 2026: 4 reportsOct 2026: 0 reportsNov 2026: 0 reports20242025202618
Last 36 months. The most recent month may be incomplete.

Recalls naming this device

  1. Sep 20, 2022Class IIOpen, Classified

    Inadvertent energy delivery from surgical system instrument if 1) Force bipolar and bipolar instruments installed on system 2) Force bipolar connected to Force Triad generator, bipolar not connected to generator 3) Yellow pedal associated with force bipolar is pressed, released with head in surgeon console 4) Blue pedal associated with bipolar is pressed, resulting in force bipolar energy delivery

    Z-0133-2023 · Root cause: Software Design Change · Recall details · FDA record ↗

Most reported problems

Device problems

  • Visual Prompts will not Clear52
  • No Display/Image25
  • Output Problem13
  • Display or Visual Feedback Problem11
  • No Device Output11
  • Physical Resistance/Sticking11
  • Failure to Power Up10
  • Failure to Sense5

Patient problems

  • No Clinical Signs, Symptoms or Conditions145
  • Insufficient Information19
  • Unspecified Tissue Injury11
  • No Known Impact Or Consequence To Patient2

Recent adverse event reports

The 25 most recent of 175 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 25, 2026Failure to Power Up

    Patient problems: Insufficient Information

    MAUDE report 50904522 ↗
  • MalfunctionSep 24, 2026No Display/Image

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50891143 ↗
  • MalfunctionSep 10, 2026Visual Prompts will not Clear

    Refer to H11 for Follow-Up information.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50724443 ↗
  • MalfunctionSep 2, 2026Failure to Power Up

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50575971 ↗
  • MalfunctionAug 28, 2026Failure to Power Up

    Patient problems: Insufficient Information

    MAUDE report 50509517 ↗
  • MalfunctionAug 28, 2026Visual Prompts will not Clear

    Patient problems: Insufficient Information

    MAUDE report 50509476 ↗
  • MalfunctionAug 19, 2026Visual Prompts will not Clear

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50332609 ↗
  • MalfunctionAug 13, 2026Visual Prompts will not Clear; Output Problem

    Patient problems: Insufficient Information

    MAUDE report 50231339 ↗
  • MalfunctionAug 13, 2026No Display/Image

    Patient problems: Insufficient Information

    MAUDE report 50231290 ↗
  • MalfunctionAug 12, 2026Visual Prompts will not Clear

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50228051 ↗
  • MalfunctionAug 8, 2026Connection Problem

    It was reported that prior to starting in a da Vinci-assisted surgical procedure, no ports placed, the customer identified Vision Side Cart (VSC) did not progress self-test and Surgeon Side Console (SSC) displayed message not connected to Vision Side Cart (VSC). Technical Support Engineer (TSE) observed recoverable error message/fault 31016, pointing at SSC being at different software level than VSC. The customer elected to swap SSC available on site to continue with the procedure.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50185201 ↗
  • MalfunctionJul 28, 2026Display or Visual Feedback Problem

    Patient problems: Insufficient Information

    MAUDE report 50062254 ↗
  • MalfunctionJul 28, 2026No Display/Image

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50062208 ↗
  • MalfunctionMay 22, 2026Output Problem

    IT WAS REPORTED THAT DURING A DA VINCI-ASSISTED SURGICAL PROCEDURE, THERE WAS A LOSS OF VIDEO ON THE LEFT SIDE DISPLAY OF THE SURGEON SIDE CONSOLE (SSC) HIGH RESOLUTION STEREO VIEWER (HRSV) WAS OBSERVED. THE CALLER STATED THAT ALL WIRING AND CABLES HAD BEEN CHECKED AND NOTHING APPEARED DAMAGED OR DISCONNECTED. IT WAS ALSO NOTED THAT THE SYSTEM MONITORS CONTINUOUSLY DISPLAYED A SELF-TEST IN PROGRESS PLEASE WAIT MESSAGE. NO FURTHER INFORMATION WAS PROVIDED. THE PROCEDURE WAS CONTINUED WITH NO REPORTED INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25260810 ↗
  • MalfunctionMay 18, 2026Visual Prompts will not Clear; Output Problem

    IT WAS REPORTED THAT DURING A DA VINCI-ASSISTED CHOLECYSTECTOMY SURGICAL PROCEDURE, THE CUSTOMER CALLED TO REPORT REPEATED FAULTS ON THE UNIVERSAL SURGICAL MANIPULATOR (USM), SPECIFICALLY A 25521 ERROR, WHICH PREVENTED ONE OF THE SURGEONS FROM CONTROLLING ARM 4. THE INTUITIVE SURGICAL, INC. (ISI) TECHNICAL SUPPORT ENGINEER (TSE) REVIEWED AND CONFIRMED THE 25521 ERROR RELATED TO THE RIGHT MASTER TOOL MANIPULATOR (MTM) AND VERIFIED THAT THE SITE HAD DISABLED MTM. THE TSE ADVISED THE CUSTOMER THAT THE MAIN SURGEON COULD SWITCH TO THE OTHER SURGEON SIDE CONSOLE (SSC) TO CONTROL USM 4 WITHOUT ISSUES. THE CUSTOMER CONFIRMED THAT THE OTHER SURGEON WAS ABLE TO CONTROL THE ARM. THE PROCEDURE WAS COMPLETED AS PLANNED WITH NO REPORT OF PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25197055 ↗
  • MalfunctionMay 9, 2026Failure to Sense

    IT WAS REPORTED THAT DURING A DA VINCI-ASSISTED GYNECOLOGY HYSTERECTOMY BENIGN SURGICAL PROCEDURE, THE PROCEDURE STARTED AS A DUAL SURGEON SIDE CONSOLE (SSC) SYSTEM AND ONE OF THE SYSTEM VIEWERS ON THE FIRST CONSOLE WAS NOT MOVING, AND THAT THIS SAME BEHAVIOR HAD OCCURRED ON A PRIOR DAY. TECHNICAL SUPPORT ENGINEER (TSE) CONFIRMED THAT THERE WERE NO PHYSICAL OBSTRUCTIONS PREVENTING MOVEMENT, WHICH THE CUSTOMER VERIFIED. THE SYSTEM WAS CONFIGURED AS A DUAL-CONSOLE, AND THE SURGEON WAS ACTIVELY USING THE OTHER CONSOLE. TSE INSTRUCTED THAT A FULL HARD POWER CYCLE OF THE AFFECTED CONSOLE BE PERFORMED AFTER THE PROCEDURE TO ADDRESS THE NONMOVING VIEWER. THE PROCEDURE WAS COMPLETED AS A SINGLE CONSOLE SYSTEM WITH NO REPORTED INJURY. ISI FOLLOWED UP WITH THE INITIAL REPORTER AND OBTAINED THE FOLLOWING ADDITIONAL INFORMATION: THE CUSTOMER STATED THAT THE SURGEON SIDE CONSOLE (SSC) IN QUESTION WAS A TEACHING SSC AND THEY COULD NOT MANUALLY MANIPULATE IT TO SEE COMFORTABLY.

    Patient problems: Insufficient Information

    MAUDE report 25131906 ↗
  • MalfunctionMay 1, 2026Battery Problem

    IT WAS REPORTED THAT AFTER A DA VINCI-ASSISTED SURGICAL PROCEDURE, THE ROBOT IS SHOWING ERROR 819. ROBOT WAS THE ONLY PART OF THE SYSTEM IN THE OPERATING ROOM AT THE TIME OF THE CALL SO LIVE STATUS WAS NOT WORKING IN ARTEMIS. TECHNICAL SUPPORT ENGINEER (TSE) HAD NURSE MOVE THE ROBOT AND PLUG IT INTO A DIFFERENT OUTLET, ERROR 824 APPEARED. TSE THEN NURSE HARD POWER CYCLE THE SYSTEM, ERROR 824 CONTINUED. PER THE NURSE, THE BATTERY LED IS SHOWING 1 RED SOLID LIGHT. TSE HAD NURSE UNPLUG THE ROBOT FROM THE WALL AND THE ROBOT INSTANTLY SHUT OFF. TSE ADVISED NURSE TO KEEP THE ROBOT PLUGGED IN FOR THE NEXT COUPLE TO SEE IF CHARGING RESUMES. THE PROCEDURE WAS COMPLETED WITH NO REPORTED INJURY.

    Patient problems: Insufficient Information

    MAUDE report 25054150 ↗
  • MalfunctionApr 22, 2026Vibration

    IT WAS REPORTED THAT DURING A DA VINCI-ASSISTED ENDOMETRIOSIS RESECTION AND HYSTERECTOMY BENIGN SURGICAL PROCEDURE, THAT THE CUSTOMER CONTACTED THE TECHNICAL SERVICE ENGINEER (TSE) TO REPORT NOISE COMING FROM THE MASTER TOOL MANIPULATOR LEFT (MTML). THE CUSTOMER HAD RESTARTED THE DA VINCI SYSTEM, BUT THE REPORTED COMPLAINT PERSISTED. TO COMPLETE THE SURGERY, THE CUSTOMER USED A SURGEON SIDE CONSOLE FROM ANOTHER DA VINCI SYSTEM. LIVE LOGS REVIEWED AT THAT TIME DID NOT SHOW ANY ERRORS RELATED TO THE NOISE, AND AN ONSITE VISIT WAS REQUESTED PRIOR TO THE NEXT SURGERY. IT WAS LATER REPORTED THAT THE ONSITE ENGINEER INFORMED TSE THAT THE CASE ASSOCIATED WITH THIS ISSUE HAD BEEN CONVERTED TO A LAPAROSCOPIC PROCEDURE IN THE FINAL STAGES. IT WAS SUBSEQUENTLY REPORTED THAT THE CUSTOMER CALLED DURING A LATER PROCEDURE TO REPORT ONGOING NOISE FROM THE MTML. THE PROCEDURE WAS CONVERTED TO LAPAROSCOPIC SURGERY WITH NO REPORTED INJURY. INTUITIVE SURGICAL, INC. (ISI) FOLLOWED UP AND OBTAINED THE FOLLOWING ADDITIONAL INFORMATION: DURING THE SURGICAL PROCEDURE, AN INTERMITTENT ISSUE WAS OBSERVED WITH THE MASTER TOOL MANIPULATOR LEFT, WHICH DID NOT ENTER A COMPLETELY NON-FUNCTIONAL STATE BUT EXHIBITE

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24949144 ↗
  • MalfunctionApr 21, 2026Visual Prompts will not Clear

    IT WAS REPORTED THAT DURING A TRAINING/DEMO OF THE DA VINCI SYSTEM, THE SURGEON SIDE CONSOLE'S (SSC) RIGHT MASTER TOOL MANIPULATOR (MTMR) EXPERIENCED A FAULT, AND ERROR CODE 23025 OCCURRED, DISABLING THE RMTM. THE CUSTOMER PERFORMED A HARD POWER CYCLE; HOWEVER, THE ISSUE REOCCURRED. AFTER POWERING ON THE COMPLETE SYSTEM, THE ISSUE WAS OCCURRING AGAIN. THERE WAS NO REPORT OF PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24946076 ↗
  • MalfunctionApr 15, 2026Vibration

    REFER TO H11 FOR FOLLOW-UP INFORMATION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24880765 ↗
  • MalfunctionApr 13, 2026Visual Prompts will not Clear

    IT WAS REPORTED THAT PRIOR TO STARTING A DA VINCI-ASSISTED SURGICAL PROCEDURE, THE SYSTEM FAULTED AT THE END OF THE FIRST PROCEDURE OF THE DAY WHEN MOVING THE PATIENT SIDE CART (PSC) AWAY FROM THE BED. TECHNICAL SUPPORT ENGINEER (TSE) HAD CUSTOMER PERFORM HARD POWER CYCLE AND VERIFY BLUE FIBER CABLE CONNECTIONS, BUT SYSTEM KEPT POWERING ON WITH ERROR 23. TSE LOG REVIEW SHOWED ERRORS REPORTING FROM THE LEFT MASTER TOOL MANIPULATOR (MTML) ARMNET. CUSTOMER WILL BE MOVING PROCEDURE TO OTHER DAVINCI SYSTEM ON SITE. THE PROCEDURE WAS ABORTED TO ANOTHER DV SYSTEM WITH PATIENT INVOLVEMENT.

    Patient problems: Insufficient Information

    MAUDE report 24866675 ↗
  • MalfunctionApr 13, 2026Visual Prompts will not Clear

    IT WAS REPORTED THAT DURING A DA VINCI-ASSISTED SURGICAL PROCEDURE THAT THE RIGHT MASTER TOOL MANIPULATOR (MTM) DROPPED ON ITS OWN. THE INTUITIVE TECH SUPPORT ENGINEER (TSE) REVIEWED THE SYSTEM LOGS AND FOUND ERROR 23075, INDICATING THE RIGHT MTM DRIFTED. THE SUSPECT MTM WAS CONTROLLING UNIVERSAL SURGICAL MANIPULATOR (USM) 3, WHICH HAD A LARGE NEEDLE DRIVER INSTRUMENT INSTALLED. THE INSTRUMENTS WERE SWAPPED BETWEEN USMS 1 AND 3 AND THE ISSUE REMAINED. THERE WERE NO REPORTS OF PATIENT INJURY. INTUITIVE RECEIVED THE FOLLOWING ADDITIONAL INFORMATION VIA FOLLOW UP: THE CUSTOMER WAS ABLE TO CONTINUE THE PROCEDURE ROBOTICALLY, EXPERIENCING DIFFICULTY WITH THE RIGHT MTM. THE DOCTOR COULD FEEL THE EFFECT OF THIS ISSUE ON THEIR OWN WRIST. THE CUSTOMER COMPLETED THE PROCEDURE USING ALL 4 USMS. THERE WAS A SURGICAL DELAY OF 15-20 MINUTES. THE MTMR WAS REPLACED. EVERYTHING WAS WORKING PROPERLY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24865428 ↗
  • MalfunctionApr 8, 2026Visual Prompts will not Clear

    IT WAS REPORTED THAT DURING A DA VINCI-ASSISTED PROSTATECTOMY RADICAL WITH LYMPHADENECTOMY SURGICAL PROCEDURE, THAT THE RIGHT MASTER TOOL MANIPULATOR (MTM) WAS DROPPING DURING CLINICAL USE, AND ERROR 23075 WAS DETECTED, INDICATING RIGHT MTM DRIFT. THE SYSTEM WAS CONFIGURED WITH FOUR UNIVERSAL SURGICAL MANIPULATOR (USM) ARMS, AND THE ISSUE PERSISTED WITH THE SECONDARY INSTRUMENT ON THE USM 3. THE INSTRUMENTS WERE SWAPPED BETWEEN USM ARMS, BUT THE PROBLEM REMAINED. THE PROCEDURE WAS COMPLETING AS PLANNED WITH NO REPORTED INJURY. INTUITIVE SURGICAL, INC. (ISI) FOLLOWED UP AND OBTAINED THE FOLLOWING ADDITIONAL INFORMATION: ACCORDING TO THE CUSTOMER, THE TOTAL DELAY EXPERIENCED WAS APPROXIMATELY 40 MINUTES, AND THE OPERATIVE TIME FOR THE SURGICAL PROCEDURE WAS ABOUT 4 HOURS. IT WAS CONFIRMED THAT THERE WERE NO DATA (ND) INDICATING ANY INTRA OR POST-OPERATIVE COMPLICATIONS DUE TO THE DELAY. FURTHERMORE, THE SURGEON DID NOT REPORT ANY IMPACT ON THE PROCEDURE OR THE PATIENT¿S HEALTH AS A RESULT OF THE EVENT, NOR WERE THERE ANY CONCERNS EXPRESSED REGARDING LONG-TERM COMPLICATIONS ARISING FROM THE DELAY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24815788 ↗
  • MalfunctionApr 3, 2026Failure to Power Up

    IT WAS REPORTED THAT PRIOR TO THE START OF A DA VINCI-ASSISTED SURGICAL PROCEDURE AND PRIOR TO PORTS PLACEMENT, THE SURGEON SIDE CONSOLE (SSC) WOULD NOT POWER ON, AND THE SYSTEM INDICATED THAT THE SSC WAS NOT CONNECTED. THE CUSTOMER CHECKED THE BREAKER SWITCH AND OUTLET, AND THE INTUITIVE SURGICAL, INC. (ISI) TECHNICAL SUPPORT ENGINEER (TSE) INSTRUCTED THE CUSTOMER TO FLIP THE BREAKER AND ENSURE THE CABLE WAS FULLY SEATED INTO THE WALL OUTLET. DESPITE FLIPPING THE BREAKER TO THE ON POSITION, THE CONSOLE STILL WOULD NOT POWER ON. THE CUSTOMER NOTED THAT ANOTHER PIECE OF EQUIPMENT IN THE SAME OUTLET WAS RECEIVING POWER AND TRIED ANOTHER OUTLET WITH NO CHANGE. THE CUSTOMER STATED THAT ANOTHER PATIENT SIDE CART (PSC) WAS NOT AVAILABLE. THE CUSTOMER PROCEEDED WITH THE CASE LAPAROSCOPICALLY.

    Patient problems: Insufficient Information

    MAUDE report 24783891 ↗
  • MalfunctionApr 3, 2026Visual Prompts will not Clear

    REFER TO H11 FOR FOLLOW-UP INFORMATION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24780963 ↗

FDA clearance and classification

The FDA regulates product code NAY (system,surgical,computer controlled instrument) under 21 CFR 876.1500 as a Class II device. 21 CFR 876.1500 ↗

Devices of this type normally need 510(k) clearance before sale.

Common questions about the da Vinci Xi 380723

Has the da Vinci Xi 380723 been recalled?

Yes. 1 FDA recall record names this device's identifier, and it is still open. The recall, Z-0133-2023 (Class II), began on Sep 20, 2022: Inadvertent energy delivery from surgical system instrument if 1) Force bipolar and bipolar instruments installed on system 2) Force bipolar connected to Force Triad generator, bipolar not connected to generator 3)… If you use this device, follow the manufacturer's notice and your healthcare provider's advice.

What problems have been reported with the da Vinci Xi 380723?

The FDA's MAUDE database lists 175 adverse event reports for this device, received between Jun 3, 2020 and Sep 25, 2026. In those reports, the most common specific device problems are “Visual Prompts will not Clear” (52), “No Display/Image” (25) and “Output Problem” (13); the most common patient problem is “Unspecified Tissue Injury” (11). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the da Vinci Xi 380723?

None of the reports are classified as deaths, 14 as injuries and 161 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Who makes the da Vinci Xi 380723, and is it still sold?

The FDA's device database lists Intuitive Surgical, Inc. as the company responsible for it (brand da Vinci Xi, model 380723). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other System,surgical,computer controlled instrument devices

All System,surgical,computer controlled instrument devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page