da Vinci Surgical SystemRecalls & reported problems across all models

Intuitive Surgical, Inc. · 9 models in the FDA device registry

Data updated Oct 16, 2026 from official FDA records · Editorial policy

3 open recalls name at least one da Vinci Surgical System model. Check whether yours is affected in the recall details, and contact the manufacturer or your healthcare provider.

Adverse event reports
1,459
Deaths reported
13
Injuries reported
336
Recalls
5

We found 9 models of da Vinci Surgical System by Intuitive Surgical, Inc. in the FDA's device registry (GUDID). Together they are named in 1,459 adverse event reports in the FDA's MAUDE database, received between Apr 9, 2020 and Sep 30, 2026 — classified as 13 deaths, 336 injuries, 1,109 malfunctions.

The most frequently reported specific device problem is “Visual Prompts will not Clear” (235 reports).

5 FDA recall records name at least one of these models by its device identifier, 3 still open.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event. Widely used products collect more reports, so totals can't be used to compare products or estimate failure rates. Only reports that name a model's exact device identifier are counted. What reports can and can't tell you · How this data works

Reports received per month, all models

Nov 2023: 18 reportsDec 2023: 22 reportsJan 2024: 15 reportsFeb 2024: 8 reportsMar 2024: 16 reportsApr 2024: 28 reportsMay 2024: 22 reportsJun 2024: 20 reportsJul 2024: 19 reportsAug 2024: 29 reportsSep 2024: 33 reportsOct 2024: 22 reportsNov 2024: 31 reportsDec 2024: 19 reportsJan 2025: 28 reportsFeb 2025: 14 reportsMar 2025: 38 reportsApr 2025: 24 reportsMay 2025: 39 reportsJun 2025: 39 reportsJul 2025: 43 reportsAug 2025: 42 reportsSep 2025: 14 reportsOct 2025: 28 reportsNov 2025: 32 reportsDec 2025: 34 reportsJan 2026: 30 reportsFeb 2026: 46 reportsMar 2026: 143 reportsApr 2026: 54 reportsMay 2026: 25 reportsJun 2026: 0 reportsJul 2026: 5 reportsAug 2026: 24 reportsSep 2026: 25 reportsOct 2026: 0 reports202420252026143
Last 36 months. The most recent month may be incomplete.

da Vinci Surgical System recalls

FDA recall records that name at least one of these models by its device identifier, newest first. Each recall usually covers specific models or lots, so check the details.

  1. Apr 22, 2026Open, Classified

    Operative components of surgical systems potentially distributed with E-brake retainer pin, so in event of a structural column failure, the E-brake pin would prevent E-brake engagement and may result in uncontrolled motion. In addition, if it moves/backs out it may cause restricted column range of motion and/or uncontrolled motion, which may cause patient tissue injury/crushing injury/bleeding.

    Z-2521-2026 · Root cause: Process control · Recall details · FDA record ↗

  2. Mar 13, 2024Open, Classified

    Surgical system may have inadequately welded top and/or bottom belts in the link 2 of the entry guide manipulator assembly/instrument arm joints, that may cause the following, 1) Top Failure: internal tissue injuries, body wall injury or emergent conversion to open surgery, 2) Bottom failure: pinching injury to the user with no harm to the patient.

    Z-1518-2024 · Root cause: Nonconforming Material/Component · Recall details · FDA record ↗

  3. Sep 20, 2022Open, Classified

    Inadvertent energy delivery from surgical system instrument if 1) Force bipolar and bipolar instruments installed on system 2) Force bipolar connected to Force Triad generator, bipolar not connected to generator 3) Yellow pedal associated with force bipolar is pressed, released with head in surgeon console 4) Blue pedal associated with bipolar is pressed, resulting in force bipolar energy delivery

    Z-0133-2023 · Root cause: Software Design Change · names 2 of these models · Recall details · FDA record ↗

  4. Jun 22, 2022Completed

    Due to preventative maintenance (PM) not being performed on E-100 generators which is a bipolar electrosugical unit designed to be used with the da Vinci Xi and X systems.

    Z-1484-2022 · Root cause: Process design · Recall details · FDA record ↗

  5. Mar 3, 2022Completed

    Placing excessive tissue in the instrument jaws of the devices prior to sealing and transection can result in an insufficient seal.

    Z-1210-2022 · Root cause: Use error · Recall details · FDA record ↗

Most reported da Vinci Surgical System problems

Device problems

  • Visual Prompts will not Clear235
  • Output Problem201
  • Adverse Event Without Identified Device or Use Problem103
  • Failure to Deliver Energy90
  • Detachment of Device or Device Component89
  • No Device Output85
  • Energy Output Problem77
  • Difficult to Open or Close63

Patient problems

  • No Clinical Signs, Symptoms or Conditions1,073
  • Insufficient Information132
  • Unspecified Tissue Injury84
  • Hemorrhage/Blood Loss/Bleeding53
  • Foreign Body In Patient42
  • Burn(s)15
  • Hematoma9
  • No Known Impact Or Consequence To Patient9

da Vinci Surgical System models

9 models, most reported first. Each model has its own page with its reports, recalls and device details.

Recent da Vinci Surgical System adverse event reports

The 15 most recent reports across all models, in the reporter's own words as published by the FDA.

Other Intuitive Surgical, Inc. products

All Intuitive Surgical, Inc. devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page