Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00886874123188), received between Jan 14, 2026 and Jan 14, 2026 — classified as 1 injury.

The most frequently reported specific device problem is “Display or Visual Feedback Problem” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 1 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Display or Visual Feedback Problem1

Patient problems

  • Unspecified Tissue Injury1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryJan 14, 2026Display or Visual Feedback Problem

    IT WAS REPORTED THAT DURING A DA VINCI-ASSISTED SURGICAL PROCEDURE, THE IMAGE THROUGH THE ENDOSCOPE WENT BLACK. THE CUSTOMER DID NOT HAVE A BACKUP ENDOSCOPE AVAILABLE FOR TROUBLESHOOTING. THE CUSTOMER REPORTEDLY HAD AN INSTRUMENT ON THE PATIENT'S GALL BLADDER. THE INTUITIVE SURGICAL, INC. (ISI) TECHNICAL SUPPORT ENGINEER (TSE) ASKED IF THEY COULD VISUALIZE THE INSTRUMENTS AND IF THEY HAD A THIRD PARTY SCOPE TO USE. THE SURGICAL STAFF PROCEEDED WITH LAPAROSCOPIC SCOPE AND THE TSE WALKED THE CUSTOMER THROUGH REMOVING INSTRUMENTS MANUALLY. THE CUSTOMER WAS ABLE TO REMOVE THE INSTRUMENTS AND UNDOCK FROM THE PATIENT. THE CUSTOMER TRIED POWER CYCLING THE SYSTEM BUT THE ENDOSCOPE WOULD NOT PASS A SELF-TEST. THE CUSTOMER THEN ELECTED TO CONVERT THE PROCEDURE TO MULTI-PORT SURGERY IN ORDER TO COMPLETE THE CASE.

    Patient problems: Unspecified Tissue Injury

    MAUDE report 24072341 ↗

Other System, surgical, computer controlled instrument devices

All System, surgical, computer controlled instrument devices →