Skip to content

Olympus WA4KL130Recalls & reported problems

OLYMPUS Winter & Ibe GmbH · Telescope "ULTRA", 10 mm, 30° · Class 2

Data updated Oct 13, 2026 from official FDA records · Editorial policy

Quick summary

This Olympus ULTRA telescope, a rigid laparoscope used to view inside the body during gynecologic surgery, has 116 adverse event reports on file. Many describe lenses detaching, chipping or breaking, often found during device evaluation with no patient involved. The reports include no deaths and no injuries, and no recalls name this device.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
117
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 117 adverse event reports that list this exact device (DI 04042761082853), received between Dec 1, 2022 and Sep 8, 2026 — classified as 117 malfunctions.

The most frequently reported specific device problem is “Break” (46 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 7 reportsDec 2023: 3 reportsJan 2024: 1 reportsFeb 2024: 5 reportsMar 2024: 4 reportsApr 2024: 2 reportsMay 2024: 5 reportsJun 2024: 3 reportsJul 2024: 1 reportsAug 2024: 2 reportsSep 2024: 2 reportsOct 2024: 1 reportsNov 2024: 3 reportsDec 2024: 2 reportsJan 2025: 0 reportsFeb 2025: 8 reportsMar 2025: 2 reportsApr 2025: 1 reportsMay 2025: 3 reportsJun 2025: 4 reportsJul 2025: 1 reportsAug 2025: 2 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 1 reportsDec 2025: 3 reportsJan 2026: 3 reportsFeb 2026: 6 reportsMar 2026: 6 reportsApr 2026: 1 reportsMay 2026: 2 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 1 reportsSep 2026: 1 reportsOct 2026: 0 reports2024202520268
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break46
  • Detachment of Device or Device Component29
  • Loose or Intermittent Connection10
  • Crack7
  • Mechanical Problem7
  • Poor Quality Image6
  • Component Missing5
  • Material Separation3

Patient problems

  • No Clinical Signs, Symptoms or Conditions116
  • Insufficient Information1

Recent adverse event reports

The 25 most recent of 117 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 8, 2026Mechanics Altered

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50672749 ↗
  • MalfunctionAug 14, 2026Detachment of Device or Device Component

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50253905 ↗
  • MalfunctionMay 5, 2026Detachment of Device or Device Component

    IT WAS OBSERVED DURING DEVICE EVALUATION, THE MENISCUS OF RIGID OPTICAL TELESCOPE WAS LOOSEN APART. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25084877 ↗
  • MalfunctionMay 1, 2026Detachment of Device or Device Component

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE RIGID OPTICAL LAPAROSCOPE EXHIBITED DETACHED LENS. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25056584 ↗
  • MalfunctionApr 30, 2026Detachment of Device or Device Component

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE RIGID OPTICAL LAPAROSCOPE EXHIBITED CHIPPED OBJECTIVE LENS. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25052602 ↗
  • MalfunctionMar 24, 2026Material Fragmentation

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE RIGID OPTICAL LAPAROSCOPE HAD MENISCUS CHIPPED OF OBJECTIVE WINDOW. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24680563 ↗
  • MalfunctionMar 23, 2026Detachment of Device or Device Component

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE RIGID OPTICAL LAPAROSCOPE HAD DETACHED DISTAL END LENS. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24661231 ↗
  • MalfunctionMar 23, 2026Break; Detachment of Device or Device Component

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE RIGID OPTICAL LAPAROSCOPE EXHIBITED DETACHED AND BROKEN LENS AT DISTAL TERMINAL. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24660234 ↗
  • MalfunctionMar 19, 2026Break; Detachment of Device or Device Component

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE RIGID OPTICAL LAPAROSCOPE EXHIBITED DETACHED AND DAMAGED DISTAL END LENS. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24637402 ↗
  • MalfunctionMar 3, 2026Loose or Intermittent Connection

    NO ADDITIONAL INFORMATION FROM THE CUSTOMER.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24498110 ↗
  • MalfunctionMar 2, 2026Detachment of Device or Device Component

    IT WAS REPORTED THE RIGID OPTICAL LAPAROSCOPE HAS LOST THE LIGHT GUIDE ADAPTER DURING SET UP. THERE WERE NO REPORTS OF PATIENT HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24484693 ↗
  • MalfunctionFeb 23, 2026Detachment of Device or Device Component

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE RIGID OPTICAL LAPAROSCOPE EXHIBITED IMAGE BUNDLE WAS SEPARATED FROM BUNDLE TIP. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24421205 ↗
  • MalfunctionFeb 19, 2026Loose or Intermittent Connection

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE RIGID OPTICAL LAPAROSCOPE HAD LOOSE BLUE RING. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24393164 ↗
  • MalfunctionFeb 19, 2026Detachment of Device or Device Component

    NO NEW ADDITIONAL INFORMATION RECEIVED FROM CUSTOMER.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24389690 ↗
  • MalfunctionFeb 19, 2026Crack

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE RIGID OPTICAL LAPAROSCOPE HAD CRACKED LENS. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24389527 ↗
  • MalfunctionFeb 16, 2026Break

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE RIGID OPTICAL LAPAROSCOPE PRESENTED TIP COVER GLASS DAMAGED. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24343512 ↗
  • MalfunctionFeb 4, 2026Break

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE RIGID TELESCOPE EXHIBITED DAMAGED OBJECTIVE WINDOW. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24259231 ↗
  • MalfunctionJan 28, 2026Detachment of Device or Device Component

    NO ADDITIONAL INFORMATION RECEIVED FROM THE CUSTOMER.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24202668 ↗
  • MalfunctionJan 23, 2026Detachment of Device or Device Component

    IT WAS REPORTED THAT THE RIGID OPTICAL LAPAROSCOPE HAD THE EYEPIECE CUP COME OFF. THE ISSUE WAS FOUND DURING MAINTENANCE. THERE WERE NO REPORTS OF PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24161777 ↗
  • MalfunctionJan 15, 2026Detachment of Device or Device Component

    NO OTHER ADDITIONAL INFORMATION FROM THE CUSTOMER.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24078971 ↗
  • MalfunctionDec 30, 2025Unstable; Unstable

    IT WAS OBSERVED THAT DURING DEVICE EVALUATION, THE RIGID OPTICAL LAPAROSCOPE EXHIBITED LIGHT GUIDE (LG)-ROD WAS LOOSE. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23923829 ↗
  • MalfunctionDec 10, 2025Loose or Intermittent Connection; Loose or Intermittent Connection

    IT WAS REPORTED THAT RIGID OPTICAL LAPAROSCOPE HAD LOOSE EYEPIECE. THE ISSUE WAS IDENTIFIED DURING A VIDEO-ASSISTED THORACOSCOPIC THERAPEUTIC PROCEDURE. THE PROCEDURE WAS COMPLETED USING AN OLYMPUS BACK-UP DEVICE. THERE WERE NO REPORTS OF PATIENT HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23767049 ↗
  • MalfunctionDec 4, 2025Poor Quality Image; Poor Quality Image

    NO ADDITIONAL INFORMATION RECEIVED FROM COSTUMER.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23715108 ↗
  • MalfunctionNov 12, 2025Incomplete or Missing Packaging; Incomplete or Missing Packaging

    NO ADDITIONAL INFORMATION RECEIVED FROM CUSTOMER.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23533988 ↗
  • MalfunctionAug 28, 2025Crack; Material Rupture; Crack; Material Rupture

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE SUBJECT DEVICE EXHIBITED FRACTURED THE WIRE OF LIGHT GUIDE BUNDLE, AND THE CRACKED LENS AT DISTAL END. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22913506 ↗

Other Laparoscope, Gynecologic (And Accessories) devices

All Laparoscope, Gynecologic (And Accessories) devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page