Fabius MRI 8607300Recalls & reported problems

Drägerwerk AG & Co. KGaA · Class 2

Adverse event reports
19
Deaths reported
0
Injuries reported
1
Recalls naming it
1

Summary

The FDA's MAUDE database contains 19 adverse event reports that list this exact device (DI 04048675041498), received between Jul 24, 2020 and Oct 22, 2025 — classified as 1 injury, 18 malfunctions.

The most frequently reported specific device problem is “Failure to Deliver” (15 reports).

1 FDA recall record name this device's identifier.

3 other recalls cover devices cleared under the same FDA submission (K072884); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 1 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 1 reportsApr 2024: 1 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 2 reportsSep 2024: 1 reportsOct 2024: 1 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 2 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 1 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 1 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Recalls naming this device

  1. Dec 16, 2021Terminated

    26 Fabius MRI Anesthesia machines were distributed with internal hoses routing Oxygen to the Oxygen Flush and Oxygen Flow Control interchanged. If the hospital O2 Central supply pressure is not stable, the O2 fresh gas flow could deviate from the adjusted value. If the deviation is not noticed, insufficient oxygenation of the patient may occur.

    Z-0501-2022 · Root cause: Process control · FDA record ↗

Most reported problems

Device problems

  • Failure to Deliver15
  • Gas Output Problem11
  • Use of Device Problem4
  • Pressure Problem3
  • Incorrect Interpretation of Signal2
  • Insufficient Device Problem Information2
  • No Apparent Adverse Event2
  • Protective Measures Problem2

Patient problems

  • No Clinical Signs, Symptoms or Conditions15
  • Insufficient Information2
  • Altered State of Consciousness1
  • Hypoxia1
  • No Consequences Or Impact To Patient1

Recent adverse event reports

The 19 most recent of 19 reports, in the reporter's own words as published by the FDA.

  • MalfunctionOct 22, 2025Gas Output Problem; Failure to Deliver; Pressure Problem; Gas Output Problem; Failure to Deliver; Pressure Problem

    IT WAS REPORTED THAT THE O2 CENTRE SENSOR FAILED AND A VENTILATOR FAILURE OCCURED. NO INJURY REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23355719 ↗
  • MalfunctionMay 8, 2025Failure to Deliver; Insufficient Device Problem Information; Failure to Deliver; Insufficient Device Problem Information

    IT WAS REPORTED THAT THE FABIUS MRI REBOOTED 3 TIMES DURING VENTILATION WHEN THE RADIOLOGIST STARTING SCANNING THE PATIENT. THE DEVICE WAS WELL BEHIND THE MARKED LINE ON THE FLOOR AND NO ALARMS INDICATED THAT THE DEVICE WAS TOO CLOSE TO THE MAGNET. THE SCREEN WENT BLACK WITH THE COMMAND TEXT VISIBLE ON THE SCREEN, VENTILATION WAS CEASED AND THIS REOCCURRED A FURTHER TWO TIMES BEFORE SCANNING WAS CEASED AND THE DEVICE WAS PULLED OUT OF THE ROOM. THE ANESTHETIST CONTINUED THE CASE WITH THE MACHINE POSITIONED OUTSIDE OF THE MRI ROOM FOLLOWING A SYSTEM TEST WAS INDICATED THE MACHINE WAS FUNCTIONAL. NO INJURY REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21983400 ↗
  • MalfunctionJan 9, 2025Gas Output Problem; Incorrect Interpretation of Signal; Failure to Deliver; Gas Output Problem; Incorrect Interpretation of Signal; Failure to Deliver

    IT WAS REPORTED THAT THE DEVICE ALARMED ¿VENTILATOR FAILURE¿ ON A PATIENT DURING PRESSURE CONTROL. PATIENT COULD BE VENTILATED MANUALLY BY ANAESTHETIST INSIDE MRI SCANNER. NO INJURY REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21109143 ↗
  • MalfunctionJan 9, 2025Gas Output Problem; Incorrect Interpretation of Signal; Failure to Deliver; Gas Output Problem; Incorrect Interpretation of Signal; Failure to Deliver

    IT WAS REPORTED THAT THE DEVICE ALARMED ¿VENTILATOR FAILURE¿ ON A PATIENT DURING PRESSURE SUPPORT. PATIENT WAS ABLE TO BE VENTILATED ON MAN/SPONT. NO INJURY REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21109087 ↗
  • MalfunctionOct 11, 2024Gas Output Problem; Failure to Deliver; Protective Measures Problem; Gas Output Problem; Failure to Deliver; Protective Measures Problem

    IT WAS REPORTED THAT THE FABIUS HAD A VENTILATOR FAILURE, NO PATIENT INJURY REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20426235 ↗
  • MalfunctionSep 9, 2024Gas Output Problem; Failure to Deliver; Pressure Problem; Gas Output Problem; Failure to Deliver; Pressure Problem

    IT WAS REPORTED THAT THE DEVICE FAILED TO VENTILATE DURING A PROCEDURE AND A "VENTILATION FAILURE" MESSAGE WAS DISPLAYED ON THE SCREEN. NO INJURY REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20168843 ↗
  • MalfunctionAug 1, 2024Gas Output Problem; Failure to Deliver; Protective Measures Problem; Gas Output Problem; Failure to Deliver; Protective Measures Problem

    IT WAS REPORTED THAT THE VENTILATOR SOUNDS LOUDER THAN NORMAL. BASED ON THE LOG ANALYSIS A VENTILATOR FAILURE OCCURRED DUE TO A NEGATIVE AIRWAY PRESSURE. NO INJURY REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19881731 ↗
  • MalfunctionAug 1, 2024Gas Output Problem; Failure to Deliver; Pressure Problem; Gas Output Problem; Failure to Deliver; Pressure Problem

    IT WAS REPORTED THAT THE DEVICE FAILED TO VENTILATE DURING A PROCEDURE AND A "VENTILATION FAILURE" MESSAGE WAS DISPLAYED ON THE SCREEN. NO INJURY REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19881730 ↗
  • MalfunctionApr 26, 2024Use of Device Problem; No Apparent Adverse Event; Use of Device Problem; No Apparent Adverse Event

    IT WAS REPORTED THERE WAS A VENTILATOR FAILURE DURING USE. NO INJURY REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19189971 ↗
  • MalfunctionMar 13, 2024Use of Device Problem; Use of Device Problem

    IT WAS REPORTED THAT THE MACHINE REBOOTED FIVE TIMES DURING THE CASE AND EACH TIME BOOTED UP TO MAN/SPONT MODE. NO INJURY REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18892676 ↗
  • MalfunctionNov 2, 2023Gas Output Problem; Failure to Sense; Failure to Deliver; Power Problem; Gas Output Problem; Failure to Sense; Failure to Deliver; Power Problem

    IT WAS REPORTED THERE WAS A VENT FAIL AND AC FAIL. NO INJURY REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18053615 ↗
  • MalfunctionJun 22, 2023Failure to Deliver; Therapeutic or Diagnostic Output Failure; Unexpected Shutdown; Failure to Deliver; Therapeutic or Diagnostic Output Failure; Unexpected Shutdown

    IT WAS REPORTED THE DEVICE REBOOTED DURING USE. THERE WAS NO PATIENT INJURY REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17180323 ↗
  • MalfunctionApr 4, 2023Output Problem; Insufficient Device Problem Information; Output Problem; Insufficient Device Problem Information

    IT WAS REPORTED THAT THE VENTILATOR WAS INOP. NO PATIENT INJURY REPORTED.

    Patient problems: Insufficient Information

    MAUDE report 16673947 ↗
  • InjuryJan 16, 2023Use of Device Problem; Failure to Calibrate; No Apparent Adverse Event; Use of Device Problem; Failure to Calibrate; No Apparent Adverse Event

    IT WAS REPORTED THAT A PATIENT HAD AN ACUTE HYPOXEMIA. RESUSCITATION MANEUVERS WERE PERFORMED. IN CONSEQUENCE A VEGETATIVE STATE WAS REPORTED.

    Patient problems: Altered State of Consciousness; Hypoxia

    MAUDE report 16172959 ↗
  • MalfunctionOct 12, 2022Failure to Deliver; Unexpected Shutdown; Failure to Deliver; Unexpected Shutdown

    IT WAS REPORTED DURING A CASE THAT THE UNIT HAD RESTARTED MOMENTARILY AND WENT BACK TO DEFAULT SETTINGS. THERE WAS NO PATIENT INJURY REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15586001 ↗
  • MalfunctionAug 25, 2022Gas Output Problem; Failure to Deliver; Electrical Overstress; Gas Output Problem; Failure to Deliver; Electrical Overstress

    IT WAS REPORTED THAT THE VENTILATOR STOPPED DURING USE OF THE DEVICE. IT WAS MENTIONED THAT NO CONSEQUENCES TO THE PATIENT HAVE RESULTED FROM THAT; PATIENT SUPPORT WAS DONE IN MAUNAL VENTILATION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15291348 ↗
  • MalfunctionDec 21, 2021Use of Device Problem; Failure to Deliver; Use of Device Problem; Failure to Deliver

    IT WAS REPORTED THAT A VENTILATOR FAILURE OCCURRED DURING USE. THERE WAS NO PATIENT INJURY REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13051922 ↗
  • MalfunctionOct 6, 2021Intermittent Continuity; Gas Output Problem; Failure to Deliver; Intermittent Continuity; Gas Output Problem; Failure to Deliver

    IT WAS REPORTED THAT THE UNIT RESTARTED MULTIPLE TIMES DURING USE. THERE WAS NO PATIENT INJURY REPORTED.

    Patient problems: Insufficient Information

    MAUDE report 12582050 ↗
  • MalfunctionJul 24, 2020Gas Output Problem; Loss of Threshold; Failure to Deliver; Gas Output Problem; Loss of Threshold; Failure to Deliver

    PLEASE REFER TO INITIAL MFR. REPORT #9611500-2020-00259.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10319007 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K072884. One submission often covers many models, so check the product and lot details in each record.

  • Z-2252-2018 · May 24, 2018 · Terminated
    Fabius GS MRI Anesthesia Machine; Cat. no. 8607300 Product Usage: Inhalation anesthesia machines for use in operating, induction and recovery rooms. They may be used with O2, N2O,
  • Z-1481-2018 · Mar 1, 2018 · Terminated
    Fabius MRI, anesthesia machine, catalog no. 8607300 Product Usage: The products are inhalation anesthesia machines for use in operating, induction and recovery rooms. They may be
  • Z-2271-2015 · Jun 22, 2015 · Terminated
    Fabius MRI Anesthesia Machine; Fabius MRI is an inhalation anesthesia machine for use in MRI environments in operating, induction and recovery rooms.

Other Gas-Machine, Anesthesia devices