System SOMATOM Confidence 10590100Recalls & reported problems
Siemens Healthcare GmbH · Class 2
Data updated Oct 16, 2026 from official FDA records · Editorial policy
1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 1
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 04056869011011), received between Dec 30, 2020 and Oct 24, 2025 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Image Display Error/Artifact” (1 report).
1 FDA recall record name this device's identifier, 1 still open.
13 other recalls cover devices cleared under the same FDA submission (K162302, K190578, K230421); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Recalls naming this device
- Nov 19, 2021Open, Classified
Software version VB20_SP5 my lead to a relevant degradation of head image quality, a potential risk to patients is misdiagnosis.
Z-0472-2022 · Root cause: Software Design Change · Recall details · FDA record ↗
Most reported problems
Device problems
- Image Display Error/Artifact1
- Positioning Failure1
Patient problems
- No Clinical Signs, Symptoms or Conditions2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionOct 24, 2025Image Display Error/Artifact; Image Display Error/Artifact
IT WAS REPORTED TO SIEMENS THAT A MALFUNCTION OCCURRED WHILE OPERATING THE SOMATOM CONFIDENCE CT SCANNER LOCATED IN GERMANY. THE CUSTOMER REPORTED THE FOLLOWING SYSTEM BEHAVIOR: WHEN USING THE RT_RESP SCAN PROTOCOL IN COMBINATION WITH THE OPEN INTERFACE, THE RESPIRATORY CURVE IS IMPORTED INTO THE SYSTEM AFTER THE SCAN. SUBSEQUENTLY, IMAGE RECONSTRUCTION IS PERFORMED IN ¿AVERAGE¿ MODE AS WELL AS IN MULTIPHASE SERIES WITH PHASES RANGING FROM 0% TO 100% IN 10% INCREMENTS. IT WAS OBSERVED THAT, SPORADICALLY, THE SERIES DESCRIPTIONS AND THE IMAGE CONTENTS DO NOT MATCH. ALTHOUGH THE SERIES ARE LABELED WITH DIFFERENT PHASE IDENTIFIERS (E.G., 0%, 10%, 20%, ETC.), THE IMAGES SHOW IDENTICAL CONTENT, AND THE PATIENT¿S RESPIRATORY MOTION IS NOT VISIBLE. WHEN THE RECONSTRUCTION IS REPEATED, THE RESULTING IMAGES ARE CORRECT AND DISPLAY THE EXPECTED DIFFERENCES IN RESPIRATORY PHASES. THESE CT IMAGES ARE USED FOR RADIOTHERAPY PLANNING. IT CAN BE RULED OUT THAT THE IMAGES ARE USED DIRECTLY FOR TREATMENT DELIVERY, AS THEY ARE FIRST IMPORTED INTO AN EXTERNAL PLANNING SYSTEM. THE ACTUAL TREATMENT PLANNING IS THEN PERFORMED BY MEDICAL PHYSICISTS AND PHYSICIANS. DURING THIS STEP, THE DESCRIBED ISSUE (UN
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23377456 ↗MalfunctionDec 30, 2020Positioning Failure; Positioning Failure
IT WAS REPORTED TO SIEMENS THAT THE GANTRY OF THE SOMATOM CONFIDENCE SYSTEM WAS SLIGHTLY TILTED BUT THE DISPLAY SHOWED AN UPRIGHT POSITION (0 DEGREES). THIS INCORRECT GANTRY POSITION WAS DOCUMENTED IN THE DICOM IMAGES AS WELL. SINCE THIS SYSTEM IS USED FOR RADIATION THERAPY (RT), THIS ISSUE IS A SAFETY CONCERN. CLARIFICATION FROM THE USER REPORTED THERE WAS NO INJURY TO THE PATIENT EXCEPT FOR SOME REPEATED PLANNING CT SCANS (EXACT NUMBER NOT PROVIDED). THE USER DID VISUALLY RECOGNIZE THE DEVIATION OF THE CT GANTRY POSITION ON THE SAME DATE (DECEMBER 04, 2020) BEFORE THE RT PLAN WAS CALCULATED. IF THE GANTRY POSITION AND DISPLAY DEVIATION ARE NOT RECOGNIZED BY THE USER, A TREATMENT PLAN COULD HAVE BEEN CREATED BASED ON THE IMAGES WITH THE INCORRECT GANTRY TILT ANGLE. THIS COULD RESULT IN TREATMENT DOSE TO THE WRONG LOCATION AND IN A WORST-CASE SCENARIO, MAY RESULT IN PATIENT INJURY. THE EXTENT OF THIS INCORRECT DOSE APPLICATION CANNOT BE QUANTIFIED, HOWEVER, SINCE IT IS DEPENDENT ON THE INDIVIDUAL TREATMENT PLAN FOR EACH PATIENT. AS OF THE DATE OF THIS REPORT, NO PATIENT INJURY RESULTING FROM THIS ISSUE HAS BEEN REPORTED TO SIEMENS. THE REPORTED EVENT OCCURRED IN (B)(6).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11095638 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K162302, K190578, K230421. One submission often covers many models, so check the product and lot details in each record.
- Z-0473-2022 · Nov 19, 2021 · Open, ClassifiedSOMATOM Definition AS-Computed tomography system Model 8098027
- Z-0475-2022 · Nov 19, 2021 · Open, ClassifiedSOMATOM Definition Edge -Computed tomography system Model 10590000
- Z-0474-2022 · Nov 19, 2021 · Open, ClassifiedSOMATOM Edge Plus-Computed tomography system Model 1026700
- Z-0285-2022 · Aug 30, 2021 · TerminatedSOMATOM Definition Edge with software syngo.CT VB20 Model #10590000
- Z-0289-2022 · Aug 30, 2021 · TerminatedSOMATOM Edge Plus with software syngo.CT VB20 Model #10267000
- Z-0284-2022 · Aug 30, 2021 · TerminatedSOMATOM Definition AS with software syngo.CT VB20 Model #8098027
- Z-0288-2022 · Aug 30, 2021 · TerminatedSOMATOM Confidence with software syngo.CT VB20 Model #10590100
- Z-0286-2022 · Aug 30, 2021 · TerminatedSOMATOM Definition Flash with software syngo.CT VB20 Model #10430603
- Z-0283-2022 · Aug 30, 2021 · TerminatedSOMATOM Force with software syngo.CT VB20 Model #10742326
- Z-0287-2022 · Aug 30, 2021 · TerminatedSOMATOM Drive with software syngo.CT VB20 Model #10431700
- Z-2440-2019 · Jul 25, 2019 · Terminatedsyngo.CT software version VA48A_SP5.5 in the following SOMATOM computed tomography models: SOMATOM Definition Edge-Model #10590000; SOMATOM Definition AS Model #8098027; SOMATOM De
- Z-2272-2019 · Jul 3, 2019 · TerminatedSOMATOM Confidence, Model Number 10590100 - Product Usage: Computed tomography systems intended to generate and process cross-sectional images of patients by computer reconstructio
- Z-2270-2019 · Jul 3, 2019 · TerminatedSOMATOM Definition Flash, Model Number 10430603 - Product Usage: Computed tomography systems intended to generate and process cross-sectional images of patients by computer reconst
Other System, x-ray, tomography, computed devices
- ARTIS icono biplane 11327600Siemens Healthcare GmbH · System, x-ray, tomography, computed15 recalls2 deaths55 reports
- ARTIS icono floor 11327700Siemens Healthcare GmbH · System, x-ray, tomography, computed15 recalls24 reports
- Incisive CTPhilips Healthcare (Suzhou) Co., Ltd. · System, x-ray, tomography, computed13 recalls5 reports
- Spectral CTPhilips Medical Systems Nederland B.V. · System, x-ray, tomography, computed11 recalls3 reports
- Incisive CTPhilips Healthcare (Suzhou) Co., Ltd. · System, X-Ray, Tomography, Computed9 recalls20 reports
- Brilliance iCTPhilips Medical Systems Nederland B.V. · System, x-ray, tomography, computed8 recalls6 reports
- Revolution Apex EliteGE Medical Systems, L.L.C. · System, x-ray, tomography, computed8 recalls0 reports
- Brilliance CT Big BorePhilips Medical Systems Nederland B.V. · System, x-ray, tomography, computed7 recalls1 report
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026 · each recall links to the FDA recall notice
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page