BLUEENDO 02-33117Recalls & reported problems
TROKAMED GmbH · Grip Module V2.0, 5-times-use for Morcellator System · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 04251303811435), received between Jun 27, 2023 and Dec 5, 2023 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Failure to Shut Off” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Failure to Shut Off2
Patient problems
- No Clinical Signs, Symptoms or Conditions2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionDec 5, 2023Failure to Shut Off; Failure to Shut Off
THE PROBLEM WAS REPORTED TO US VIA CUSTOMER COMPLAINT (B)(4) ON (B)(6) 2023: WHEN USING THE MORCELLATOR, THE CUTTING MODULE CONTINUED TO ROTATE EVEN THOUGH THE ACTIVATION SWITCH OF THE HANDLE MODULE WAS RELEASED BY THE USER. THE UB-20230501_MORCELLATOR_SCHALTER INVESTIGATION REPORT WAS PREPARED TO ANALYZE THE CAUSE.THE CAUSE OF THE ERROR PATTERN WAS FOUND TO BE A FAULTY SWITCH FUNCTION, I.E. THE CONTACT DISTANCES OF THE SWITCH MAY BE TOO SMALL. THE SEAT OF THE FIXING SCREW OF THE ACTIVATION SWITCH IN THE GRIP MODULE WAS TESTED WITH AN UNSUITABLE TESTING DEVICE. AS A RESULT, PRODUCTS WITH TOO SMALL A SWITCH CONTACT DISTANCE (CONTACT SCREW TO SPRING PLATE) HAVE COME INTO CIRCULATION. WITH THESE PRODUCTS, IT IS THEREFORE POSSIBLE THAT THE GRIP MODULE TRANSMITS AN "ON" SIGNAL TO THE CONTROL UNIT EVEN AFTER THE ACTIVATION SWITCH HAS BEEN RELEASED AND THAT THE CUTTING MODULE CONTINUES TO ROTATE EVEN AFTER THE ACTIVATION SWITCH HAS BEEN RELEASED.REASON FOR FSCA: URGENT SAFETY INFORMATION IS BEING ISSUED TO REDUCE THE RISK OF THE OCCURRENCE OF A SIGNIFICANT DELAY IN THE MEDICAL PROCEDURE IF A USER HAS TO MAKE AN UNPLANNED CHANGE FROM HAND TO FOOT CONTROL DURING A PROCEDURE DUE TO THE SUDDE
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18265377 ↗MalfunctionJun 27, 2023Failure to Shut Off; Failure to Shut Off
THE PROBLEM WAS REPORTED TO US VIA CUSTOMER COMPLAINT (B)(4) ON (B)(6).2023: WHEN USING THE MORCELLATOR, THE CUTTING MODULE CONTINUED TO ROTATE EVEN THOUGH THE ACTIVATION SWITCH OF THE HANDLE MODULE WAS RELEASED BY THE USER. THE UB-20230501_MORCELLATOR_SCHALTER INVESTIGATION REPORT WAS PREPARED TO ANALYZE THE CAUSE.THE CAUSE OF THE ERROR PATTERN WAS FOUND TO BE A FAULTY SWITCH FUNCTION, I.E. THE CONTACT DISTANCES OF THE SWITCH MAY BE TOO SMALL. THE SEAT OF THE FIXING SCREW OF THE ACTIVATION SWITCH IN THE GRIP MODULE WAS TESTED WITH AN UNSUITABLE TESTING DEVICE. AS A RESULT, PRODUCTS WITH TOO SMALL A SWITCH CONTACT DISTANCE (CONTACT SCREW TO SPRING PLATE) HAVE COME INTO CIRCULATION. WITH THESE PRODUCTS, IT IS THEREFORE POSSIBLE THAT THE GRIP MODULE TRANSMITS AN "ON" SIGNAL TO THE CONTROL UNIT EVEN AFTER THE ACTIVATION SWITCH HAS BEEN RELEASED AND THAT THE CUTTING MODULE CONTINUES TO ROTATE EVEN AFTER THE ACTIVATION SWITCH HAS BEEN RELEASED.REASON FOR FSCA: URGENT SAFETY INFORMATION IS BEING ISSUED TO REDUCE THE RISK OF THE OCCURRENCE OF A SIGNIFICANT DELAY IN THE MEDICAL PROCEDURE IF A USER HAS TO MAKE AN UNPLANNED CHANGE FROM HAND TO FOOT CONTROL DURING A PROCEDURE DUE TO THE SUDDE
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17210931 ↗
Other Laparoscope, Gynecologic (And Accessories) devices
- Olympus WA50042AOLYMPUS Winter & Ibe GmbH · Laparoscope, Gynecologic (And Accessories)1 recall6,135 reports
- Olympus WA50052AOLYMPUS Winter & Ibe GmbH · Laparoscope, Gynecologic (And Accessories)2,249 reports
- ENDOEYE FLEX DEFLECTABLE VIDEOSCOPE OLYMPUS LTF-S190-5Olympus Medical Systems Corp. · LAPAROSCOPE, GYNECOLOGIC (AND ACCESSORIES)1 recall1,279 reports
- Olympus WA50040AOLYMPUS Winter & Ibe GmbH · Laparoscope, Gynecologic (And Accessories)1 recall954 reports
- Olympus WA50050AOLYMPUS Winter & Ibe GmbH · Laparoscope, Gynecologic (And Accessories)895 reports
- ENDOEYE FLEX DEFLECTABLE VIDEOSCOPE OLYMPUS LTF-S190-5Olympus Medical Systems Corp. · Laparoscope, Gynecologic (And Accessories)624 reports
- Epix Laparoscopic Scissors CB030Applied Medical Resources Corporation · Laparoscope, Gynecologic (And Accessories)239 reports
- HD EndoEYE LAPARO-THORACO VIDEOSCOPE OLYMPUS LTF TYPE VHOlympus Medical Systems Corp. · LAPAROSCOPE, GYNECOLOGIC (AND ACCESSORIES)168 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page