CONNECTING TUBE MAJ-1971Recalls & reported problems
Olympus Medical Systems Corp. · Class 2
All models of CONNECTING TUBE (23)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 7
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 7 adverse event reports that list this exact device (DI 04953170329623), received between Jun 1, 2020 and May 2, 2024 — classified as 7 malfunctions.
The most frequently reported specific device problem is “Break” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Break3
- Device Reprocessing Problem2
- Detachment of Device or Device Component1
- Device Contamination with Chemical or Other Material1
- Obstruction of Flow1
Patient problems
- No Clinical Signs, Symptoms or Conditions5
- No Consequences Or Impact To Patient1
- No Patient Involvement1
Recent adverse event reports
The 7 most recent of 7 reports, in the reporter's own words as published by the FDA.
MalfunctionMay 2, 2024Break; Break
IT WAS REPORTED THAT THE YELLOW CONNECTOR OF THE CONNECTING TUBE WAS FOUND BROKEN DURING THE PREVENTIVE MAINTENANCE INSPECTION. THERE WAS NO PATIENT INVOLVEMENT, NO HARM OR USER INJURY REPORTED DUE TO THE EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19230160 ↗MalfunctionAug 2, 2023Break; Break
THE CUSTOMER REPORTED TO OLYMPUS TECHNICAL ASSISTANCE CENTER (TAC), DURING THE REPROCESSING, THE YELLOW CONNECTING TUBE WAS NOTED TO BE BROKEN. THERE WAS NO HARM OR USER INJURY REPORTED DUE TO THE EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17442334 ↗MalfunctionApr 7, 2023Detachment of Device or Device Component; Detachment of Device or Device Component
THE CUSTOMER REPORTED TO OLYMPUS, THE CONNECTING TUBE COULD NOT BE CONNECTED TO THE CHANNEL CONNECTOR AND IT BROKE OFF DUE TO WEAR AND TEAR. THE ISSUE WAS FOUND DURING REPROCESSING. THERE WERE NO REPORTS OF PATIENT HARM.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16704247 ↗MalfunctionNov 23, 2022Obstruction of Flow; Obstruction of Flow
THE CUSTOMER REPORTED THE OER-4 AUTOMATIC ENDOSCOPE REPROCESSOR (AER) AND CONNECTING TUBE WERE USED TO WASH A SCOPE. WHEN WASHING THE SCOPE, THE CONNECTING TUBE WAS CLOGGED AND IT WAS POSSIBLE THAT THE AUXILIARY WATER PIPE AND CHANNEL COULD NOT BE WASHED. IT WAS UNKNOWN IF THE INSUFFICIENTLY CLEANED SCOPE WAS USED ON A PATIENT. THERE WAS NO REPORTED PATIENT HARM OR IMPACT DUE TO THIS EVENT. THE CLOGGING WAS RESOLVED AND THE SCOPE WAS CLEANED AGAIN WITHOUT PROBLEMS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15851468 ↗MalfunctionJan 20, 2022Device Reprocessing Problem; Device Contamination with Chemical or Other Material; Device Reprocessing Problem; Device Contamination with Chemical or Other Material
OLYMPUS MEDICAL SYSTEMS CORP. (OMSC) WAS INFORMED FROM THE FIELD SERVICE ENGINEER OF OLYMPUS THAT IT WAS FOUND SOMETHING LIKE WATER STAIN AT THE TIP OF THE INSERTION PART OF THE ENDOSCOPE (GIF-2TQ260M) WHEN IT WAS CONDUCTED THE PERIODIC INSPECTION AT THE USER FACILITY. THIS INDICATED THAT THE USER MAY HAVE USED THE POOR REPROCESSING SUBJECT DEVICE FOR NEXT PROCEDURE. THE USER USES AN OLYMPUS AUTOMATED ENDOSCOPE REPROCESSOR MODEL OER-4 AFTER BRUSHING. IN ADDITION, THE USER ALSO INFORMED AND CONCERNED AS FOLLOWINGS; SINCE THERE WERE NO ABNORMALITIES WITH OTHER ENDOSCOPES, IT WAS SAID THAT THERE WAS NO PROBLEM WITH BRUSHING AND CLEANING PROCEDURES. THE USER CONCERNED THAT THE OWNED CONNECTING TUBES (MAJ-1500, MAJ-1503, MAJ-1971/THE SUBJECT DEVICE) CONNECTED TO THE WASHER MAY BE RELATED TO THIS PHENOMENON THAT THEY FLOAT DURING CLEANING. THERE WAS NO ABNORMALITY IN THE APPEARANCE OF THE TUBE DURING CLEANING, BUT IT FLOATED DURING CLEANING. THERE WAS CONCERN THAT THE CONNECTING TUBE MAY HAVE BECOME SHORTER DUE TO DETERIORATION OF DIRECT SUNLIGHT, THE CLAWS OF THE CLEANING TUBE MAY HAVE BECOME WORSE, OR THERE MAY HAVE BEEN SOME INITIAL FAILURE. THERE WAS NO REPORT OF PATIENT INJURY ASSOC
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 13301396 ↗MalfunctionOct 30, 2020Device Reprocessing Problem; Device Reprocessing Problem
DURING THE PREPARATION FOR USE, THE USER FOUND THAT THERE WAS A WHITE FOREIGN MATERIAL IN THE TUBE OF THE PRODUCT. THERE WAS NO REPORT OF PATIENT INJURY ASSOCIATED WITH THIS EVENT. THE USER FACILITY DID NOT PROVIDE OTHER DETAILED INFORMATION.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10761392 ↗MalfunctionJun 1, 2020Break; Break
IT WAS REPORTED THAT DURING REPROCESSING THE PLASTIC CONNECTOR ON THE SCOPE WASHER ACCESSORY CABLE WAS FOUND TO BE BROKEN. NO HARM WAS CAUSED BY THIS ISSUE AND THE BROKEN CONNECTOR WAS NOT USED ONCE IT WAS FOUND THE TAB WAS BROKEN.
Patient problems: No Patient Involvement
MAUDE report 10105960 ↗
Other ACCESSORIES, CLEANING, FOR ENDOSCOPE devices
- ENDOSCOPE REPROCESSOR OER-ProOlympus Medical Systems Corp. · ACCESSORIES, CLEANING, FOR ENDOSCOPE3 recalls1,163 reports
- ENDOSCOPE REPROCESSOR OER-EliteOlympus Medical Systems Corp. · Accessories, cleaning, for endoscope4 recalls323 reports
- SINGLE USE DISTAL COVER MAJ-2315Olympus Medical Systems Corp. · Accessories, Cleaning, For Endoscope2 recalls294 reports
- CONNECTING TUBE MAJ-2110Olympus Medical Systems Corp. · Accessories, Cleaning, For Endoscope1 recall213 reports
- CONNECTING TUBE MAJ-2111Olympus Medical Systems Corp. · Accessories, Cleaning, For Endoscope1 recall164 reports
- CONNECTING TUBE MAJ-2113Olympus Medical Systems Corp. · Accessories, Cleaning, For Endoscope1 recall159 reports
- CONNECTING TUBE MAJ-2112Olympus Medical Systems Corp. · Accessories, Cleaning, For Endoscope1 recall143 reports
- ENDOSCOPE REPROCESSOR OER-MINIOlympus Medical Systems Corp. · Accessories, Cleaning, For Endoscope2 recalls11 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page