Single Use 3-Lumen Sphincterotome V KD-V411M-0320 (REF N5411130)Recalls & reported problems
Olympus Medical Systems Corp. · Class 2
All models of Single Use 3-Lumen Sphincterotome V (31)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.
- Adverse event reports
- 12
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 1
Summary
The FDA's MAUDE database contains 12 adverse event reports that list this exact device (DI 04953170380556), received between Jul 13, 2020 and Dec 30, 2025 — classified as 12 malfunctions.
The most frequently reported specific device problem is “Break” (9 reports).
1 FDA recall record name this device's identifier, 1 still open.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Recalls naming this device
- Jan 7, 2026Class IIOpen, Classified
Devices which did not undergo thermoforming could deform and lose performance.
Z-1268-2026 · Root cause: Process control · Recall details · FDA record ↗
Most reported problems
Device problems
- Break9
- Peeled/Delaminated2
- Detachment of Device or Device Component1
Patient problems
- No Clinical Signs, Symptoms or Conditions11
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 12 most recent of 12 reports, in the reporter's own words as published by the FDA.
MalfunctionDec 30, 2025Peeled/Delaminated; Peeled/Delaminated
NO ADDITIONAL INFORMATION RECEIVED FROM CUSTOMER.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23931434 ↗MalfunctionOct 29, 2025Break; Break
IT WAS REPORTED THE SINGLE USE SPHINCTEROTOME'S CUTTING WIRE BROKE. THIS WAS REPORTED TO HAVE OCCURRED DURING AN UNSPECIFIED THERAPEUTIC PROCEDURE. THERE WERE NO REPORTS OF PATIENT HARM.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23413897 ↗MalfunctionOct 15, 2025Peeled/Delaminated; Peeled/Delaminated
IT WAS REPORTED THE SPHINCTEROTOME THE PROTECTIVE LAYER ON THE CUTTING EDGE DELAMINATED. THE ISSUE OCCURRED THERAPEUTIC ENDOSCOPIC RETROGRADE CHOLANGIOPANCREATOGRAPHY (ERCP) PROCEDURE PROLONGED LESS THAN 30 MINUTES. THE PROCEDURE WAS COMPLETED WITH SAME DEVICE. THERE WERE NO REPORTS OF PATIENT HARM.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23279208 ↗MalfunctionJun 2, 2025Break; Break
IT WAS REPORTED WHEN USING THE SUBJECT DEVICE, THE FILAMENT BROKE DURING AN UNSPECIFIED PROCEDURE ON THREE SEPARATE OCCASIONS IN THREE DIFFERENT PATIENTS. IT'S UNKNOWN HOW THE PROCEDURE WAS COMPLETED AND THERE WERE NO REPORT OF PATIENT HARM. REPORT 3 OF 3.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22125824 ↗MalfunctionJun 2, 2025Break; Break
IT WAS REPORTED WHEN USING THE SUBJECT DEVICE, THE FILAMENT BROKE DURING AN UNSPECIFIED PROCEDURE ON THREE SEPARATE OCCASIONS IN THREE DIFFERENT PATIENTS. IT'S UNKNOWN HOW THE PROCEDURE WAS COMPLETED AND THERE WERE NO REPORT OF PATIENT HARM. REPORT 2 OF 3.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22125614 ↗MalfunctionJun 2, 2025Break; Break
IT WAS REPORTED WHEN USING THE SUBJECT DEVICE, THE FILAMENT BROKE DURING AN UNSPECIFIED PROCEDURE ON THREE SEPARATE OCCASIONS IN THREE DIFFERENT PATIENTS. IT'S UNKNOWN HOW THE PROCEDURE WAS COMPLETED AND THERE WERE NO REPORT OF PATIENT HARM. REPORT 1 OF 3.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22125509 ↗MalfunctionOct 4, 2024Break; Break
IT WAS REPORTED THAT THE SINGLE USE LUMEN SPHINCTEROTOME, THE KNIFE WIRE BROKE (WHEN ELECTRICITY WAS APPLIED), BUT DID NOT FALL OUT. THE EVENT OCCURRED DURING THE PROCEDURE. THE PROCEDURE WAS THERAPEUTIC. THERE WERE NO REPORTS OF PATIENT HARM.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20372112 ↗MalfunctionSep 14, 2023Detachment of Device or Device Component; Detachment of Device or Device Component
THE CUSTOMER REPORTED TO OLYMPUS THE SINGLE USE 3-LUMEN SPHINCTEROTOME V TIP WIRE WAS BROKEN AT THE FIRST ENERGIZATION. THE REPORTED ISSUE OCCURRED DURING A THERAPEUTIC ENDOSCOPIC SPHINCTEROTOMY (EST) PROCEDURE. THE CUSTOMER CONFIRMED THAT NO DEBRIS FELL OFF. THE PROCEDURE WAS SUBSEQUENTLY COMPLETED WITH A SIMILAR DEVICE WITH NO DELAY. THERE WAS NO PATIENT/USER HARM OR INJURY REPORTED DUE TO THE EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17752607 ↗MalfunctionOct 26, 2022Break; Break
THE CUSTOMER REPORTED TO OLYMPUS THAT DURING AN ENDOSCOPIC RETROGRADE CHOLANGIOPANCREATOGRAPHY (ERCP), WHEN THE PAPILLOTOME WAS BEING USED TO COMPLETE THE SPHINCTEROTOMY, AND AS SOON AS THE ELECTRO SCALPEL WAS USED, THE BLADE OF THE PAPILLOTOME BROKE. A SECOND PAPILLOTOME (SUBJECT DEVICE), OF THE SAME MODEL AND SAME BATCH, WAS USED AND THE BLADE BROKE AGAIN. THE PROCEDURE WAS COMPLETED USING A PAPILLOTOME FROM ANOTHER COMPANY. THERE WAS A SLIGHT DELAY OF 5-10 MINUTES WHILE CHANGING OUT THE DEVICES. THE BROKEN PIECE DID NOT FALL INSIDE THE PATIENT. THERE WAS NO REPORT OF PATIENT OR USER HARM ASSOCIATED WITH THIS EVENT. THE PRODUCT WAS REPORTEDLY INSPECTED PRIOR TO USE, AND NO PROBLEMS WERE DETECTED. EVENT 2 OF 2: THIS REPORT IS BEING SUBMITTED FOR THE ISSUE WITH THE SECOND PAPILLOTOME DEVICE (SINGLE USE 3-LUMEN SPHINCTEROTOME V), ON THE MEDWATCH WITH PATIENT IDENTIFIER (B)(6) THE ISSUE WITH THE FIRST PAPILLOTOME DEVICE WAS REPORTED UNDER THE MEDWATCH WITH PATIENT IDENTIFIER (B)(6).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15677971 ↗MalfunctionOct 26, 2022Break; Break
THE CUSTOMER REPORTED TO OLYMPUS THAT DURING AN ENDOSCOPIC RETROGRADE CHOLANGIOPANCREATOGRAPHY (ERCP), WHEN THE PAPILLOTOME (SUBJECT DEVICE) WAS BEING USED TO COMPLETE THE SPHINCTEROTOMY, AND AS SOON AS THE ELECTRO SCALPEL WAS USED, THE BLADE OF THE PAPILLOTOME BROKE. A SECOND PAPILLOTOME (SAME MODEL AND SAME BATCH) WAS USED AND THE BLADE BROKE AGAIN. THE PROCEDURE WAS COMPLETED USING A PAPILLOTOME FROM ANOTHER COMPANY. THERE WAS A SLIGHT DELAY OF 5-10 MINUTES WHILE CHANGING OUT THE DEVICES. THE BROKEN PIECE DID NOT FALL INSIDE THE PATIENT. THERE WAS NO REPORT OF PATIENT OR USER HARM ASSOCIATED WITH THIS EVENT. THE PRODUCT WAS REPORTEDLY INSPECTED PRIOR TO USE, AND NO PROBLEMS WERE DETECTED. EVENT 1 OF 2: THIS REPORT IS BEING SUBMITTED FOR THE ISSUE WITH THE FIRST PAPILLOTOME DEVICE (SINGLE USE 3-LUMEN SPHINCTEROTOME V), UNDER THE MEDWATCH WITH PATIENT IDENTIFIER (B)(6). THE ISSUE WITH THE SECOND PAPILLOTOME DEVICE IS BEING REPORTED ON THE MEDWATCH WITH PATIENT IDENTIFIER (B)(6).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15677964 ↗MalfunctionMay 10, 2022Break; Break
THE CUSTOMER REPORTED THE SINGLE USE 3-LUMEN SPHINCTEROTOME V KNIFE BROKE AT THE TIP. THE EVENT OCCURRED DURING A DIAGNOSTIC ENDOSCOPIC RETROGRADE CHOLANGIOPANCREATOGRAPHY PROCEDURE. THE OPERATION WAS COMPLETED BY REPLACING THE PRODUCT AND THERE WAS NO PATIENT HARM OR USER INJURY REPORTED DUE TO THE EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 14350361 ↗MalfunctionJul 13, 2020Break; Break
DURING AN ENDOSCOPIC SPHINCTEROTOMY (EST), THE SUBJECT DEVICE WAS USED. WHEN THE USER INSERTED THE SUBJECT DEVICE INTO THE PAPILLA AND TRIED TO CUT THE SPHINCTER, THE CUTTING WIRE BROKE OFF AND FELL. THE FRAGMENT CAME OUT WITH THE SUBJECT DEVICE. THE INTENDED PROCEDURE WAS COMPLETED WITH ANOTHER DEVICE. THERE WAS NO PATIENT INJURY REPORTED. THIS IS THE REPORT REGARDING THE FALLING OF THE CUTTING WIRE.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10263552 ↗
Other Unit, electrosurgical, endoscopic (with or without accessories) devices
- THUNDERBEAT 5 mm, 35 cm, Front-actuated Grip TB-0535FCOlympus Medical Systems Corp. · Unit, electrosurgical, endoscopic (with or without accessories)1 recall2 deaths404 reports
- SONICBEAT 5 mm, 35 cm, Front-actuated Grip SB-0535FCOlympus Medical Systems Corp. · Unit, electrosurgical, endoscopic (with or without accessories)379 reports
- Single Use Electrosurgical Knife KD-611LOlympus Medical Systems Corp. · Unit, electrosurgical, endoscopic (with or without accessories)1 death357 reports
- Autotome™ RX 44 M00545170Boston Scientific Corporation · Unit, electrosurgical, endoscopic (with or without accessories)1 recall262 reports
- TRUEtome 44 M00584170Boston Scientific Corporation · Unit, electrosurgical, endoscopic (with or without accessories)237 reports
- Dreamtome™ RX 44 M00584040Boston Scientific Corporation · Unit, electrosurgical, endoscopic (with or without accessories)1 recall165 reports
- Dreamtome™ RX 44 M00584050Boston Scientific Corporation · Unit, electrosurgical, endoscopic (with or without accessories)1 recall127 reports
- Single Use 3-Lumen Sphincterotome V KD-V411M-0725Olympus Medical Systems Corp. · Unit, electrosurgical, endoscopic (with or without accessories)160 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026 · each recall links to the FDA recall notice
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page