Single Use Preloaded Sphincterotome V(Distal Wireguided) KD-VC631Q-07203S (REF N5779430)Recalls & reported problems

Olympus Medical Systems Corp. · Single Use Preloaded Sphincterotome V(Distal Wireguided) · Class 2

All models of Single Use Preloaded Sphincterotome V (Distal Wireguided) (18)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
11
Deaths reported
0
Injuries reported
5
Recalls naming it
0

Summary

The FDA's MAUDE database contains 11 adverse event reports that list this exact device (DI 04953170399503), received between Apr 15, 2024 and Apr 8, 2026 — classified as 5 injuries, 6 malfunctions.

The most frequently reported specific device problem is “Break” (5 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 1 reportsMay 2024: 1 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 1 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 1 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 2 reportsNov 2025: 3 reportsDec 2025: 1 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 1 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520263
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break5
  • Detachment of Device or Device Component5
  • Device Fell1
  • Difficult to Insert1
  • Material Deformation1
  • Peeled/Delaminated1

Patient problems

  • Foreign Body In Patient5
  • No Clinical Signs, Symptoms or Conditions4
  • Insufficient Information2

Recent adverse event reports

The 11 most recent of 11 reports, in the reporter's own words as published by the FDA.

  • MalfunctionApr 8, 2026Difficult to Insert

    NO ADDITIONAL INFORMATION RECEIVED FROM THE CUSTOMER.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24823649 ↗
  • InjuryDec 19, 2025Break; Detachment of Device or Device Component; Break; Detachment of Device or Device Component

    IT WAS REPORTED THAT DURING A THERAPEUTIC ENDOSCOPIC RETROGRADE CHOLANGIOPANCREATOGRAPHY (ERCP) THE TIP BROKE AND FELL INTO THE PATIENT. THE CUSTOMER DID NOT RETRIEVE THE TIP.

    Patient problems: Foreign Body In Patient

    MAUDE report 23857424 ↗
  • InjuryNov 20, 2025Detachment of Device or Device Component; Detachment of Device or Device Component

    IT WAS REPORTED THAT WHEN USING THE SINGLE USE PRELOADED SPHINCTEROTOME DURING AN ENDOSCOPIC RETROGRADE CHOLANGIOPANCREATOGRAPHY, THE PHYSICIAN NOTICED A MARK OR DOT ON THE X-RAY IMAGE. THE DEVICE WAS TAKEN OUT TO BE INSPECTED, NO DAMAGE WAS SEEN, AND THE DEVICE WAS INSERTED BACK INTO THE SCOPE. WHEN THE WIRE WAS INSERTED BACK INTO THE BILIARY DUCT UNDER X-RAY, THE MARK OR DOT WAS GONE. A SMALL PIECE OF METAL WAS OBSERVED NEXT TO THE DUCT. THE PHYSICIAN NOTED THAT THE PIECE OF METAL CAME FROM THE WIRE, AND THAT THERE WAS A PIECE MISSING AT THE JUNCTION OF THE SOFT PART OF THE WIRE AND WIRE CORE ITSELF, WHICH COULD BE THIS PIECE OF METAL. THE PHYSICIAN DETERMINED TO LEAVE THE METAL PIECE IN PLACE SINCE IT WILL BE VOIDED NATURALLY. THERE WERE NO REPORTS OF FURTHER PATIENT HARM.

    Patient problems: Foreign Body In Patient

    MAUDE report 23612354 ↗
  • InjuryNov 20, 2025Detachment of Device or Device Component; Detachment of Device or Device Component

    IT WAS REPORTED THAT WHEN USING THE SINGLE USE PRELOADED SPHINCTEROTOME DURING AN ENDOSCOPIC RETROGRADE CHOLANGIOPANCREATOGRAPHY, THE PHYSICIAN NOTICED A MARK OR DOT ON THE X-RAY IMAGE. THE DEVICE WAS TAKEN OUT TO BE INSPECTED, NO DAMAGE WAS SEEN, AND THE DEVICE WAS INSERTED BACK INTO THE SCOPE. WHEN THE WIRE WAS INSERTED BACK INTO THE BILIARY DUCT UNDER X-RAY, THE MARK OR DOT WAS GONE. A SMALL PIECE OF METAL WAS OBSERVED NEXT TO THE DUCT. THE PHYSICIAN NOTED THAT THE PIECE OF METAL CAME FROM THE WIRE, AND THAT THERE WAS A PIECE MISSING AT THE JUNCTION OF THE SOFT PART OF THE WIRE AND WIRE CORE ITSELF, WHICH COULD BE THIS PIECE OF METAL. THE PHYSICIAN DETERMINED TO LEAVE THE METAL PIECE IN PLACE SINCE IT WILL BE VOIDED NATURALLY. THERE WERE NO REPORTS OF FURTHER PATIENT HARM.

    Patient problems: Foreign Body In Patient

    MAUDE report 23612332 ↗
  • MalfunctionNov 3, 2025Material Deformation; Material Deformation

    IT WAS REPORTED THE SINGLE USE PRELOADED SPHINCTEROTOME V(DISTAL WIREGUIDED) WAS STRIPPED AT THE TIP. THE ISSUE OCCURRED DURING A THERAPEUTIC ENDOSCOPIC RETROGRADE CHOLANGIOPANCREATOGRAPHY PROCEDURE AND WAS COMPLETED USING AN OLYMPUS BACK-UP DEVICE. THERE WERE NO REPORTS OF PATIENT HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23453713 ↗
  • InjuryOct 21, 2025Break; Detachment of Device or Device Component; Break; Detachment of Device or Device Component

    IT WAS REPORTED THAT DURING AN ENDOSCOPIC RETROGRADE CHOLANGIOPANCREATOGRAPHY (ERCP), THE SINGLE USE PRELOADED SPHINCTEROTOME WIRE BROKE AND FELL INTO THE PATIENT¿S PANCREATIC DUCT. THE SURGEON ATTEMPTED TO RETRIEVE THE BROKEN WIRE WITH GRASPING FORCEPS BUT WAS UNSUCCESSFUL. THE PATIENT RETURNED FOR AN ADDITIONAL PROCEDURE TO TRY TO REMOVE THE PIECE OF BROKEN WIRE, HOWEVER THAT WAS AGAIN UNSUCCESSFUL. A FOLLOW-UP IS SCHEDULED TO DISCUSS POSSIBLE SURGERY.

    Patient problems: Foreign Body In Patient

    MAUDE report 23354548 ↗
  • InjuryOct 21, 2025Break; Detachment of Device or Device Component; Break; Detachment of Device or Device Component

    NO ADDITIONAL INFORMATION WAS RECEIVED FROM THE CUSTOMER. THIS SUPPLEMENTAL IS BEING SUBMITTED TO CORRECT CODING. UPDATES TO B2 AND F10.

    Patient problems: Foreign Body In Patient

    MAUDE report 23354542 ↗
  • MalfunctionJun 24, 2025Break; Peeled/Delaminated; Break; Peeled/Delaminated

    IT WAS REPORTED THE SINGLE USE PRELOADED SPHINCTEROTOME V IRON WIRE OF THE KNIFE IS BROKEN. THE ISSUE OCCURRED DURING AN ENDOSCOPIC RETROGRADE CHOLANGIOPANCREATOGRAPHY. THERE WERE NO REPORTS OF PATIENT HARM.

    Patient problems: Insufficient Information

    MAUDE report 22322005 ↗
  • MalfunctionMar 18, 2025Break; Break

    IT WAS REPORTED THAT THE CUTTING WIRE BROKE WHEN ENERGY WAS APPLIED TO THE DEVICE. TWO CUTS WERE MADE AND DEVICE FAILED. THE EVENT OCCURRED DURING A THERAPEUTIC ENDOSCOPIC RETROGRADE CHOLANGIOPANCREATOGRAPHY PROCEDURE. THE PROCEDURE WAS COMPLETED WITH A SIMILAR DEVICE. THERE WERE NO REPORTS OF PATIENT HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21629250 ↗
  • MalfunctionMay 22, 2024Device Fell; Device Fell

    IT WAS REPORTED, THE SPHINCTEROTOME V¿S WIRE FELL OFF DURING A THERAPEUTIC PROCEDURE (ENDOSCOPIC RETROGRADE CHOLANGIOPANCREATOGRAPHY). THE INTENDED PROCEDURE WAS COMPLETED USING THE SAME SET OF DEVICE. THERE WERE NO REPORTS OF PATIENT HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19373682 ↗
  • MalfunctionApr 15, 2024

    CLEVER CUT 3V USED DURING ERCP (ENDOSCOPIC RETROGRADE CHOLANGIOPANCREATOGRAPHY), AT THE TIME OF THE SPHINCTEROTOMY DURING THE BOWING, THE WIRE BROKE WHILE AT THE AMPULLA INSIDE THE PATIENT IN THE SCOPE.

    Patient problems: Insufficient Information

    MAUDE report 19104395 ↗

Other Unit, electrosurgical, endoscopic (with or without accessories) devices

All Unit, electrosurgical, endoscopic (with or without accessories) devices →