NA RF-SE-10Recalls & reported problems

St. Jude Medical, Inc. · REUSABLE RF ELECTRODE · Class 2

Data updated Oct 13, 2026 from official FDA records · Editorial policy

Adverse event reports
7
Deaths reported
0
Injuries reported
6
Recalls naming it
0

Summary

The FDA's MAUDE database contains 7 adverse event reports that list this exact device (DI 05415067025227), received between Dec 10, 2018 and Feb 27, 2024 — classified as 6 injuries, 1 malfunction.

The most frequently reported specific device problem is “Insufficient Heating” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 1 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Insufficient Heating2
  • Temperature Problem2
  • Thermal Decomposition of Device2
  • Adverse Event Without Identified Device or Use Problem1
  • Failure to Deliver Energy1
  • Melted1
  • No Apparent Adverse Event1

Patient problems

  • No Clinical Signs, Symptoms or Conditions4
  • No Consequences Or Impact To Patient2
  • Partial thickness (Second Degree) Burn2

Recent adverse event reports

The 7 most recent of 7 reports, in the reporter's own words as published by the FDA.

  • InjuryFeb 27, 2024Failure to Deliver Energy; Failure to Deliver Energy

    IT WAS REPORTED THAT DURING THE START OF AN ABLATION PROCEDURE, THE PROBE WAS NOT REGISTERING IN ANY OF THE PORTS. FURTHER INFORMATION WAS REQUESTED BUT NOT RECEIVED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18787875 ↗
  • InjuryOct 12, 2023Thermal Decomposition of Device; No Apparent Adverse Event; Thermal Decomposition of Device; No Apparent Adverse Event

    ADDITIONAL INFORMATION RECEIVED INDICATES THAT THE BURN WAS ONLY AT ONE SITE OF INSERTION. INVESTIGATION WAS UNABLE TO DETERMINE WHICH OF THE PROBE ATTRIBUTED TO THE ISSUE.

    Patient problems: No Clinical Signs, Symptoms or Conditions; Partial thickness (Second Degree) Burn

    MAUDE report 17925015 ↗
  • InjuryOct 6, 2023Thermal Decomposition of Device; Adverse Event Without Identified Device or Use Problem; Thermal Decomposition of Device; Adverse Event Without Identified Device or Use Problem

    ADDITIONAL INFORMATION RECEIVED INDICATES THAT THE BURN WAS ONLY AT ONE SITE OF INSERTION. INVESTIGATION WAS UNABLE TO DETERMINE WHICH OF THE PROBE ATTRIBUTED TO THE ISSUE.

    Patient problems: Partial thickness (Second Degree) Burn

    MAUDE report 17890360 ↗
  • InjuryJun 22, 2023Insufficient Heating; Insufficient Heating

    RELATED MANUFACTURER REFERENCE NUMBER: 3004617090-2023-00005. IT WAS REPORTED THAT DURING A PROCEDURE THE PROBES DID NOT PROPERLY HEAT TO DESIRED TEMPERATURE. AS SUCH, THE PROCEDURE WAS NOT COMPLETED. REPORTEDLY, THE DOCTOR HAD ATTEMPTED TO INSERT THE PROBES.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17183122 ↗
  • MalfunctionJun 22, 2023Insufficient Heating; Insufficient Heating

    RELATED MANUFACTURER REFERENCE NUMBER: 3004617090-2023-00006. IT WAS REPORTED THAT DURING A PROCEDURE THE PROBES DID NOT PROPERLY HEAT TO DESIRED TEMPERATURE. AS SUCH, THE PROCEDURE WAS NOT COMPLETED. REPORTEDLY, THE DOCTOR HAD ATTEMPTED TO INSERT THE PROBES.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17183114 ↗
  • InjuryDec 10, 2018Temperature Problem; Temperature Problem

    RELATED MANUFACTURER REPORT NUMBER: 3004617090-2018-00010, 3002953813-2018-00091. DURING A BI-POLAR ABLATION PROCEDURE, THE PROBES CONNECTED TO PORTS 1 AND 2 DID NOT REACH TEMPERATURE AND ONE OF THE PROBES MELTED. THE PROBES WERE REPLACED, THE GENERATOR WAS POWER CYCLED, AND THE OUTLET CHANGED, BUT THE TEMPERATURE ISSUE REMAINED. THE PROCEDURE WAS CANCELLED, BUT THERE WERE NO ADVERSE PATIENT CONSEQUENCES.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8148763 ↗
  • InjuryDec 10, 2018Melted; Temperature Problem; Melted; Temperature Problem

    RELATED MANUFACTURER REPORT NUMBER: 3002953813-2018-00091, 3004617090-2018-00011. DURING A BI-POLAR ABLATION PROCEDURE, THE PROBES CONNECTED TO PORTS 1 AND 2 DID NOT REACH TEMPERATURE AND ONE OF THE PROBES MELTED. THE PROBES WERE REPLACED, THE GENERATOR WAS POWER CYCLED, AND THE OUTLET CHANGED, BUT THE TEMPERATURE ISSUE REMAINED. THE PROCEDURE WAS CANCELLED, BUT THERE WERE NO ADVERSE PATIENT CONSEQUENCES.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8148750 ↗

Other PROBE, RADIOFREQUENCY LESION devices

All PROBE, RADIOFREQUENCY LESION devices →