Injection Gold Probe M00560160Recalls & reported problems
Boston Scientific Corporation · Bipolar Electrohemostasis Catheter · Class 2
All models of Injection Gold Probe (2)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 9
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 9 adverse event reports that list this exact device (DI 08714729056508), received between Jan 12, 2017 and Sep 1, 2026 — classified as 1 injury, 8 malfunctions.
The most frequently reported specific device problem is “Detachment of Device or Device Component” (4 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Detachment of Device or Device Component4
- Failure to Deliver Energy2
- Adverse Event Without Identified Device or Use Problem1
- Material Puncture/Hole1
- Material Separation1
- Output Problem1
- Therapeutic or Diagnostic Output Failure1
Patient problems
- No Consequences Or Impact To Patient5
- Insufficient Information2
- No Clinical Signs, Symptoms or Conditions2
Recent adverse event reports
The 9 most recent of 9 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 1, 2026Detachment of Device or Device Component
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50534789 ↗InjuryMar 16, 2023Detachment of Device or Device Component; Adverse Event Without Identified Device or Use Problem; Detachment of Device or Device Component; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT AN INJECTION GOLD PROBE NEEDLE WAS USED DURING A GASTROSCOPY PROCEDURE PERFORMED ON AN UNKNOWN DATE. DURING THE PROCEDURE, THE DISTAL GOLD TIP OF THE NEEDLE DETACHED AND FELL INTO THE PATENT'S STOMACH. A RAT TOOTH FORCEPS WAS USED TO RETRIEVE THE DETACHED DISTAL GOLD TIP AND THE PROCEDURE WAS COMPLETED WITH A SIMILAR INJECTION GOLD PROBE NEEDLE. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16554799 ↗MalfunctionMar 25, 2022Output Problem
THE PROBE DID NOT BURN. NEW PROBE WAS FROM A DIFFERENT LOT WAS OPENED. THE PRODUCT PERFORMED AS INTENDED AND NO FURTHER INTERVENTION WAS NEEDED.
Patient problems: Insufficient Information
MAUDE report 13901017 ↗MalfunctionMar 2, 2022Therapeutic or Diagnostic Output Failure
DURING AN EGD PROCEDURE, THE PROBE WAS NOT FUNCTIONING AS REQUIRED AFTER ALL SETTINGS AND MACHINERY WAS CHANGED.
Patient problems: Insufficient Information
MAUDE report 13653271 ↗MalfunctionMar 4, 2020Detachment of Device or Device Component; Detachment of Device or Device Component
IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT AN INJECTION GOLD PROBE WAS USED DURING A COLONOSCOPY PROCEDURE PERFORMED ON (B)(6) 2020. ACCORDING TO THE COMPLAINANT, DURING THE PROCEDURE, THEY ADVANCED A GOLD PROBE DOWN THE SCOPE. THEY TRIED TO ACTIVATE THE PROBE BUT NO ENERGY WAS GETTING TO THE TIP OF THE PROBE. THEY REMOVED THE PROBE AND USED ANOTHER ONE, OF A DIFFERENT LOT NUMBER. WHILE ADVANCING DOWN THE SCOPE, AND THE TIP OF THE PROBE FELL OFF INSIDE THE SCOPE. THEY RETRIEVE THE DETACHED PIECE FROM THE SCOPE USING BIOPSY FORCEPS. THE PROCEDURE WAS COMPLETED USING A THIRD INJECTION GOLD PROBE. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT. THE PATIENT'S CONDITION AT THE CONCLUSION OF THE PROCEDURE WAS REPORTED TO BE FINE.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9785170 ↗MalfunctionMar 20, 2019Detachment of Device or Device Component; Detachment of Device or Device Component
IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT AN INJECTION GOLD PROBE WAS USED IN THE DUODENUM DURING AN EMERGENT GI BLEED PROCEDURE PERFORMED ON (B)(6) 2019. ACCORDING TO THE COMPLAINANT, THE INJECTION GOLD PROBE WAS BROKEN INSIDE THE PACKAGE. THE COMPLAINANT PROVIDED A PHOTO OF THE DEVICE, WHICH SHOWS THE DISTAL TIP WAS DETACHED. THIS WAS DISCOVERED DURING THE PROCEDURE, WHILE THE DEVICE WAS DOWN THE SCOPE AND INSIDE THE PATIENT. THE PROCEDURE WAS COMPLETED WITH ANOTHER INJECTION GOLD PROBE. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT. THE PATIENT'S CONDITION AT THE CONCLUSION OF THE PROCEDURE WAS REPORTED TO BE FINE.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8438573 ↗MalfunctionJun 14, 2017Failure to Deliver Energy; Failure to Deliver Energy
IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT AN INJECTION GOLD PROBE WAS USED IN THE UPPER GI DURING A HEMOSTASIS PROCEDURE PERFORMED ON (B)(6) 2017. ACCORDING TO THE COMPLAINANT, DURING THE PROCEDURE, THE INJECTION GOLD PROBE FAILED TO CAUTERIZED. THE PROCEDURE WAS COMPLETED WITH ANOTHER INJECTION GOLD PROBE. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT. THE PATIENT'S CONDITION AT THE CONCLUSION OF THE PROCEDURE WAS REPORTED TO BE FINE.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 6639709 ↗MalfunctionJun 1, 2017Failure to Deliver Energy; Failure to Deliver Energy
IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT AN INJECTION GOLD PROBE WAS USED IN THE COLON DURING A COLONOSCOPY PROCEDURE PERFORMED ON (B)(6) 2017. ACCORDING TO THE COMPLAINANT, DURING THE PROCEDURE, THE INJECTION GOLD PROBE FAILED TO CAUTERIZED. THE PROCEDURE WAS COMPLETED WITH ANOTHER INJECTION GOLD PROBE. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT. THE PATIENT'S CONDITION AT THE CONCLUSION OF THE PROCEDURE WAS REPORTED TO BE FINE.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 6605172 ↗MalfunctionJan 12, 2017Material Puncture/Hole; Material Separation; Material Puncture/Hole; Material Separation
IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT AN UNKNOWN EVENT OCCURRED WITH AN INJECTION GOLD PROBE¿ WITH AN WHILE BEING USED IN THE COLON DESCENDENS DURING A PROCEDURE PERFORMED ON (B)(6) 2016. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT. ATTEMPTS TO OBTAIN ADDITIONAL INFORMATION REGARDING THE CIRCUMSTANCES SURROUNDING THIS EVENT HAVE BEEN UNSUCCESSFUL TO DATE. THE INVESTIGATION FOUND THE DISTAL TIP OF THE GOLD PROBE WAS DETACHED, THIS IS NOW DEEMED AN MDR REPORTABLE EVENT.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 6248148 ↗
Other Unit, electrosurgical, endoscopic (with or without accessories) devices
- THUNDERBEAT 5 mm, 35 cm, Front-actuated Grip TB-0535FCOlympus Medical Systems Corp. · Unit, electrosurgical, endoscopic (with or without accessories)1 recall2 deaths404 reports
- SONICBEAT 5 mm, 35 cm, Front-actuated Grip SB-0535FCOlympus Medical Systems Corp. · Unit, electrosurgical, endoscopic (with or without accessories)379 reports
- Single Use Electrosurgical Knife KD-611LOlympus Medical Systems Corp. · Unit, electrosurgical, endoscopic (with or without accessories)1 death357 reports
- Autotome™ RX 44 M00545170Boston Scientific Corporation · Unit, electrosurgical, endoscopic (with or without accessories)1 recall262 reports
- TRUEtome 44 M00584170Boston Scientific Corporation · Unit, electrosurgical, endoscopic (with or without accessories)237 reports
- Dreamtome™ RX 44 M00584040Boston Scientific Corporation · Unit, electrosurgical, endoscopic (with or without accessories)1 recall165 reports
- Dreamtome™ RX 44 M00584050Boston Scientific Corporation · Unit, electrosurgical, endoscopic (with or without accessories)1 recall127 reports
- Single Use 3-Lumen Sphincterotome V KD-V411M-0725Olympus Medical Systems Corp. · Unit, electrosurgical, endoscopic (with or without accessories)160 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page