McKesson 16-C60PRecalls & reported problems
Mckesson Medical-Surgical Inc. · Anesthesia Circuits COAXIAL 60" Pediatric · Class 2
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10612479210797), received between Mar 24, 2023 and Mar 24, 2023 — classified as 1 malfunction.
The most frequently reported specific device problem is “Partial Blockage” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Partial Blockage1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 24, 2023Partial Blockage; Partial Blockage
DISTAL END OF THE COAXIAL CIRCUIT HAD AN OBSTRUCTION IN THE INTERNAL (INSPIRATORY) LIMB AND WHEN THE OUTER LIMB WAS CUT OPEN, THE INTERNAL LIMB WAS FOUND TO BE TWISTED AND GREATER THAN 75% OCCLUDED. THE PATIENT DID HAVE A PROLONGED INDUCTION OF ANESTHESIA WITH OBSTRUCTED ATTEMPT TO INSPIRE AND REQUIRED IM KETAMINE THAT PROLONGED HIS RETURN TO FULL ALERTNESS AND RECOVERY FROM ANESTHESIA. WHILE THE PATIENT HAD NO HYPOXEMIA OR LONG TERM SEQUELAE DUE TO EARLY RECOGNITION OF THE DEFECT BY EXPERIENCED PRACTITIONERS, THIS MANUFACTURING DEFECT COULD HAVE CAUSED PROFOUND HYPOXEMIA, INSPIRATORY OBSTRUCTION CAUSING POST OBSTRUCTIVE. PULMONARY EDEMA OR ANESTHESIA MACHINE FAILURE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16612863 ↗
Other Filter, Bacterial, Breathing-Circuit devices
- VOCSN V+Pro, EnglishVentec Life Systems, Inc. · Filter, Bacterial, Breathing-Circuit1 recall570 reports
- VOCSN V+Pro Emergency, EnglishVentec Life Systems, Inc. · Filter, Bacterial, Breathing-Circuit558 reports
- VOCSN V+O+C+S+N+Pro, EnglishVentec Life Systems, Inc. · Filter, Bacterial, Breathing-Circuit3 recalls366 reports
- VOCSN V+Pro, EnglishVentec Life Systems, Inc. · Filter, Bacterial, Breathing-Circuit2 recalls2 deaths325 reports
- VOCSN V+C+S+N+Pro, EnglishVentec Life Systems, Inc. · Filter, Bacterial, Breathing-Circuit185 reports
- GIBECK IPN043751Teleflex Incorporated · Filter, bacterial, breathing-circuit2 recalls7 reports
- VOCSN VOCSN, EnglishVentec Life Systems, Inc. · Filter, Bacterial, Breathing-Circuit1 death96 reports
- VOCSN V+C+Pro, JapaneseVentec Life Systems, Inc. · Filter, Bacterial, Breathing-Circuit1 recall33 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.