PROXIMATE TVC55Recalls & reported problems
Ethicon Endo-Surgery, LLC · Proximate Reloadable Vascular Linear Cutter with Safety Lock-Out, 55mm · Class 2
- Adverse event reports
- 6
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 10705036013389), received between Nov 15, 2021 and Apr 21, 2025 — classified as 6 malfunctions.
The most frequently reported specific device problem is “Failure to Fire” (4 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Failure to Fire4
- Failure to Form Staple2
- Insufficient Device Problem Information1
Patient problems
- No Clinical Signs, Symptoms or Conditions6
Recent adverse event reports
The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 21, 2025Failure to Fire; Insufficient Device Problem Information; Failure to Fire; Insufficient Device Problem Information
IT WAS REPORTED THAT SURGEON PLACED STAY STITCHES TO TEMPORARILY CLOSE THE GASTROCUTANEOUS FISTULA IN ORDER TO PLACE THE STAPLER ACROSS THE GASTRIC TISSUE. SHE THEN PLACED THE STAPLER ACROSS THE TISSUE AND FIRED. THE STAPLER FIRED BUT THE SURGEON NOTICED IT WAS A LITTLE DIFFICULT TO SLIDE THE FIRING KNOB BACK AFTER IT WAS FIRED AND BEFORE OPENING THE DEVICE. ONCE THE DEVICE WAS REMOVED FROM THE TISSUE, SHE NOTICED STAPLES FORMED CORRECTLY ON ONLY THE PROXIMAL 1/3RD OF THE STAPLE LINE. THE REMAINING 2/3RDS OF THE TISSUE DID NOT HAVE ANY STAPLES AND THE TISSUE WAS STILL OPEN. SHE THEN USED VICRYL SUTURES TO CLOSE THE REMAINING PORTION OF THE TISSUE TO COMPLETE THE CASE. SURGICAL DELAY UNKNOWN. NO PATIENT HARM WAS REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21873341 ↗MalfunctionJan 18, 2024
VASCULAR GIA STAPLING DEVICE WAS THEN USED TO COME ACROSS THE FISTULA FROM THE LATERAL SIDE, BUT IT CLEARLY FULLY MISFIRED--WHEN HAD COULD CUT ACROSS ONLY APPROXIMATELY HALF OF THE TRACT WITH THE STAPLER BECAME LOCKED UP. AS SUCH, THE STAPLER WAS DISENGAGED. WE THEN USED A COMPLETELY NEW VASCULAR GIA STAPLER DEVICE WITH A NEW LOAD OF STAPLES, AND THIS TIME TRIED TO USE THAT STAPLER COMING FROM THE MEDIAL SIDE. WE WAITED AT LEAST 30 SECONDS PRIOR TO FIRING THE STAPLER AS WE HAD WITH THE FIRST STAPLER, AND AGAIN WHEN TRYING TO COMPLETE THE CUT WITH THE STAPLER, THE MECHANISMS SIMPLY WOULD NOT ADVANCE AFTER THE STAPLER HAD CUT ACROSS APPROXIMATELY HALF THE WIDTH OF THE FISTULA TRACT TISSUES ON THE MEDIAL SIDE. AS SUCH, THAT STAPLER WAS REMOVED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18535465 ↗MalfunctionSep 11, 2023Failure to Form Staple; Failure to Fire; Failure to Form Staple; Failure to Fire
IT WAS REPORTED THAT DURING THE FISTULA PROCEDURE THIS CASE WAS ON A PEDIATRIC PATIENT AND THE FISTULA WAS THIN TISSUE. SURGEON FIRED THE TVC55 ACROSS THE GASTROCUTANEOUS FISTULA. ABOUT HALFWAY THRU THE FIRING SEQUENCE, THE STAPLER LOCKED OUT. THE SURGEON SLID THE FIRING KNOB BACK AND RELEASED THE DEVICE FROM THE TISSUE. FORMED STAPLES WERE NOTED BUT NOT ON BOTH SIDES OF THE CUT LINE. THEY RELEASED THE STAPLER FROM THE TISSUE AND SUCCESSFULLY COMPLETED THE CASE WITH CLAMPS, SCISSORS, AND SUTURES. THE PROCEDURE WAS COMPLETED SUCCESSFULLY WITH NO PATIENT HARM.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17720676 ↗MalfunctionJun 22, 2022Failure to Fire; Failure to Fire
SEE ATTACHED USER FACILITY MEDWATCH.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 14775668 ↗MalfunctionJun 3, 2022Failure to Form Staple
STAPLER FIRED BUT STAPLE LINE OF ANATOMY NOT INTACT, NO STAPLES ON LINE OF ANATOMY LIKE THERE SHOULD BE, STAPLE LINE HAD TO BE SEWN CLOSED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 14591865 ↗MalfunctionNov 15, 2021Failure to Fire; Failure to Fire
IT WAS REPORTED THAT DURING HEMORRHOIDECTOMY THE DEVICE BLOCKED INTRAOPERATIVELY AND DID NOT TRIGGER. AN ADDITIONAL DEVICE WAS OPENED AND THE OP ENDED WITH NO INFLUENCE ON SURGERY AND PAT. SAFETY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12815625 ↗
Other STAPLE, IMPLANTABLE devices
- Endo GIA EGIA60AMTCovidien LP · STAPLE, IMPLANTABLE19 deaths10,680 reports
- Endo GIA Ultra EGIAUSTNDCovidien LP · STAPLE, IMPLANTABLE5 deaths9,730 reports
- Signia SIGPHANDLECovidien LP · STAPLE, IMPLANTABLE1 recall3 deaths5,356 reports
- ECHELON FLEX PSEE60AEthicon Endo-Surgery, LLC · STAPLE, IMPLANTABLE1 recall13 deaths3,294 reports
- Endo GIA Ultra EGIAUSHORTCovidien LP · STAPLE, IMPLANTABLE2 deaths3,011 reports
- Endo GIA EGIA45AMTCovidien LP · STAPLE, IMPLANTABLE10 deaths2,965 reports
- Endo GIA Ultra EGIAUXLCovidien LP · STAPLE, IMPLANTABLE2,909 reports
- ENDOPATH ATS45Ethicon Endo-Surgery, LLC · STAPLE, IMPLANTABLE2 deaths2,046 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.